These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
365 related articles for article (PubMed ID: 8817388)
21. Consistency of the initial cell acquisition procedure is critical to the standardization of CD34+ cell enumeration by flow cytometry: results of a pairwise analysis of umbilical cord blood units and cryopreserved aliquots. Flores AI; McKenna DH; Montalbán MA; De la Cruz J; Wagner JE; Bornstein R Transfusion; 2009 Apr; 49(4):636-47. PubMed ID: 19055702 [TBL] [Abstract][Full Text] [Related]
22. Automated analysis of flow cytometric data for CD34+ stem cell enumeration using a probability state model. Herbert DJ; Miller DT; Bruce Bagwell C Cytometry B Clin Cytom; 2012 Sep; 82(5):313-8. PubMed ID: 22730140 [TBL] [Abstract][Full Text] [Related]
23. Quality assurance of stem cell enumeration by flow cytometry. Canadian QASE Study Group. Chin-Yee I; Anderson L; Keeney M; Sutherland DR Cytometry; 1997 Dec; 30(6):296-303. PubMed ID: 9440821 [TBL] [Abstract][Full Text] [Related]
24. Validation of the Nordic flow cytometry standard for CD34+ cell enumeration in blood and autografts: report from the third workshop. Nordic Stem Cell Laboratory Group. Johnsen HE; Baech J; Nikolajsen K J Hematother; 1999 Feb; 8(1):15-28. PubMed ID: 10192298 [TBL] [Abstract][Full Text] [Related]
25. The influence of flow cytometric gating strategy on the standardization of CD34+ cell quantitation: an Australian multicenter study. Australasian BMT Scientists Study Group. Chang A; Ma DD J Hematother; 1996 Dec; 5(6):605-16. PubMed ID: 9117249 [TBL] [Abstract][Full Text] [Related]
26. Flow cytometric enumeration of CD34+ hematopoietic stem and progenitor cells. European Working Group on Clinical Cell Analysis. Gratama JW; Orfao A; Barnett D; Brando B; Huber A; Janossy G; Johnsen HE; Keeney M; Marti GE; Preijers F; Rothe G; Serke S; Sutherland DR; Van der Schoot CE; Schmitz G; Papa S Cytometry; 1998 Jun; 34(3):128-42. PubMed ID: 9696157 [TBL] [Abstract][Full Text] [Related]
27. Flow cytometric enumeration and immunophenotyping of hematopoietic stem and progenitor cells. Gratama JW; Sutherland DR; Keeney M; Papa S J Biol Regul Homeost Agents; 2001; 15(1):14-22. PubMed ID: 11388740 [TBL] [Abstract][Full Text] [Related]
28. Comparison of ISHAGE protocol CD34 cell enumeration with a lineage negative backgating technique. Pirruccello SJ; Page CJ; Bishop MR; Letheby BA; Warkentin PI; Jackson JD; Kessinger A Cytotherapy; 1999; 1(4):279-86. PubMed ID: 20426553 [TBL] [Abstract][Full Text] [Related]
29. Method comparison study of peripheral blood CD34+ count performed on an Abbott CELL-DYN Sapphire hematology analyzer versus flow cytometry reference procedure (modified ISHAGE). Avecilla ST; Goss C; Marionneaux SM; Wright DR; Leiva TD; Tonon JA; Smith KM; Maslak P Adv Cell Gene Ther; 2018 Sep; 1(2):. PubMed ID: 30873513 [TBL] [Abstract][Full Text] [Related]
31. Sensitive detection and enumeration of CD34+ cells in peripheral and cord blood by flow cytometry. Sutherland DR; Keating A; Nayar R; Anania S; Stewart AK Exp Hematol; 1994 Sep; 22(10):1003-10. PubMed ID: 7522181 [TBL] [Abstract][Full Text] [Related]
32. True volumetric method for flow cytometric enumeration of CD34 + stem cells and its agreement with a standard bead-based single-platform protocol. Mortazavi S; Ardalan FA; Nodehi SR; Karder FF; Miraliakbari N Cytotherapy; 2012 May; 14(5):621-9. PubMed ID: 22428601 [TBL] [Abstract][Full Text] [Related]
33. Determination of optimal replicate number for validation of imprecision using fluorescence cell-based assays: proposed practical method. Davis BH; McLaren CE; Carcio AJ; Wong L; Hedley BD; Keeney M; Curtis A; Culp NB Cytometry B Clin Cytom; 2013; 84(5):329-37. PubMed ID: 24022856 [TBL] [Abstract][Full Text] [Related]
34. CD34(+) B-cell progenitors in mobilized peripheral blood apheresis collections: implications for flow cytometric assessment of graft adequacy. Thiago LS; Sutherland DR Cytotherapy; 2015 May; 17(5):689-91. PubMed ID: 25800774 [No Abstract] [Full Text] [Related]
35. External quality assessment in clinical cell analysis by flow cytometry. Why is it so important? Siftar Z; Paro MM; Sokolić I; Nazor A; Mestrić ZF Coll Antropol; 2010 Mar; 34(1):207-17. PubMed ID: 20432753 [TBL] [Abstract][Full Text] [Related]
36. A simplified method of CD34+ cell determination for peripheral blood progenitor cell transplantation and correlation with clinical engraftment. Sandhaus LM; Edinger MG; Tubbs RR; Goormastic M; Baucco PA; Serafino SE; Bolwell BJ Exp Hematol; 1998 Jan; 26(1):73-8. PubMed ID: 9430516 [TBL] [Abstract][Full Text] [Related]
37. Flow cytometric CD34+ determination in stem cell transplantation: before or after cryopreservation of grafts? Fietz T; Reufi B; Mücke C; Thiel E; Knauf WU J Hematother Stem Cell Res; 2002 Apr; 11(2):429-35. PubMed ID: 11983115 [TBL] [Abstract][Full Text] [Related]
38. Analysis of variation in results of CD34+ hematopoietic progenitor cell enumeration in a multicenter study. Gratama JW; Kraan J; Levering W; Van Bockstaele DR; Rijkers GT; Van der Schoot CE Cytometry; 1997 Jun; 30(3):109-17. PubMed ID: 9222096 [TBL] [Abstract][Full Text] [Related]
39. Performance of a novel BD stem cell enumeration kit on two flow cytometry systems. Omana-Zapata I; Oreizy F; Mosqueda F; Salemenik M; Lin A; Wen JL; Varro R; Lee-Haynes L; Segurado OG Int J Lab Hematol; 2013 Aug; 35(4):393-9. PubMed ID: 23190563 [TBL] [Abstract][Full Text] [Related]
40. Flow cytometric CD34+ stem cell enumeration: lessons from nine years' external quality assessment within the Benelux countries. Levering WH; Preijers FW; van Wieringen WN; Kraan J; van Beers WA; Sintnicolaas K; van Rhenen DJ; Gratama JW Cytometry B Clin Cytom; 2007 May; 72(3):178-88. PubMed ID: 17397065 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]