These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 8823635)

  • 1. Equivalence of fast flush and square wave testing of blood pressure monitoring systems.
    Kleinman B; Powell S; Gardner RM
    J Clin Monit; 1996 Mar; 12(2):149-54. PubMed ID: 8823635
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The fast flush test measures the dynamic response of the entire blood pressure monitoring system.
    Kleinman B; Powell S; Kumar P; Gardner RM
    Anesthesiology; 1992 Dec; 77(6):1215-20. PubMed ID: 1466471
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Experimental analysis of catheter-manometer systems in vitro and in vivo.
    Hipkins SF; Rutten AJ; Runciman WB
    Anesthesiology; 1989 Dec; 71(6):893-906. PubMed ID: 2589678
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The fast flush test--is the clinical comparison equivalent to its in vitro simulation?
    Kleinman B; Frey K; Stevens R
    J Clin Monit Comput; 1998 Dec; 14(7-8):485-9. PubMed ID: 10385857
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dynamic response of the ROSE damping device.
    Kleinman B; Powell S
    J Clin Monit; 1989 Apr; 5(2):111-5. PubMed ID: 2723705
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Time-dependent pressure distortion in a catheter-transducer system: correction by fast flush.
    Promonet C; Anglade D; Menaouar A; Bayat S; Durand M; Eberhard A; Grimbert FA
    Anesthesiology; 2000 Jan; 92(1):208-18. PubMed ID: 10638918
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hazardous information from bedside fast-flush device test for fluid-filled pressure monitoring systems.
    Billiet E; Colardyn F
    Angiology; 1992 Dec; 43(12):988-95. PubMed ID: 1466487
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy and dynamic response of disposable pressure transducer-tubing systems.
    Hunziker P
    Can J Anaesth; 1987 Jul; 34(4):409-14. PubMed ID: 3608063
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Frequency response evaluation of radial artery catheter-manometer systems: sinusoidal frequency analysis versus flush method.
    Schwid HA
    J Clin Monit; 1988 Jul; 4(3):181-5. PubMed ID: 3210066
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dynamic response of liquid-filled catheter systems for measurement of blood pressure: precision of measurements and reliability of the Pressure Recording Analytical Method with different disposable systems.
    Romagnoli S; Romano SM; Bevilacqua S; Lazzeri C; Gensini GF; Pratesi C; Quattrone D; Dini D; De Gaudio AR
    J Crit Care; 2011 Aug; 26(4):415-22. PubMed ID: 21036533
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Recommendation of a clinical impulse response analysis for catheter calibration-dumping coefficient and natural frequency are incomplete parameters for clinical evaluation.
    Watanabe H; Yagi S; Namiki A
    J Clin Monit Comput; 2006 Feb; 20(1):37-42. PubMed ID: 16520875
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cable-testing device fails to indicate that hypertension is artifactual.
    Meyer RM; Kimovec MA; Hefner GG
    J Clin Monit; 1993 Jan; 9(1):54-9. PubMed ID: 8463806
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Construction and use of catheter-manometer systems.
    Heimann PA; Murray WB
    J Clin Monit; 1993 Jan; 9(1):45-53. PubMed ID: 8463804
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurement of arterial pressure using catheter-transducer systems. Improvement using the Accudynamic.
    Allan MW; Gray WM; Asbury AJ
    Br J Anaesth; 1988 Mar; 60(4):413-8. PubMed ID: 3355737
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [A newly devised continuous catheter flush system for arterial pressure monitoring].
    Hashimoto S; Sawa T; Chihara E; Kinoshita T; Hatanaka T; Hosokawa T; Natsuyama T; Tanaka Y
    Masui; 1989 Oct; 38(10):1378-82. PubMed ID: 2585707
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A new optical transducer for arterial pressure measurement.
    Hackman CH; Tan PS; Chakrabarti MK; Whitwam JG
    Br J Anaesth; 1991 Sep; 67(3):346-52. PubMed ID: 1911027
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Invasive blood pressure monitoring systems in the ICU: influence of the blood-conserving device on the dynamic response characteristics and agreement with noninvasive measurements.
    Melamed R; Johnson K; Pothen B; Sprenkle MD; Johnson PJ
    Blood Press Monit; 2012 Oct; 17(5):179-83. PubMed ID: 22797516
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dynamic response of a neonatal catheter-manometer system in situ.
    van Langen H; Brienesse P; Kopinga K; Wijn P
    J Clin Monit; 1993 Nov; 9(5):335-40. PubMed ID: 8106887
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dynamics of invasive pressure monitoring systems: clinical and laboratory evaluation.
    Gibbs NC; Gardner RM
    Heart Lung; 1988 Jan; 17(1):43-51. PubMed ID: 3338943
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The fast flush test: evaluation in radial artery catheter-manometer systems.
    Sheahan NF; Tuohy B; Kirkham R; Coakley D; Malone J
    Clin Phys Physiol Meas; 1991 Aug; 12(3):247-52. PubMed ID: 1934911
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.