BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 8828776)

  • 1. Safety margin of magnetic coupling distance in decoupling of a pivot bearing-supported Gyro centrifugal pump (C1E3).
    Takami Y; Nakazawa T; Makinouchi K; Glueck J; Benkowski R; Nosé Y
    Artif Organs; 1996 Jul; 20(7):817-9. PubMed ID: 8828776
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative approach to control spinning stability of the impeller in the pivot bearing-supported centrifugal pump.
    Takami Y; Makinouchi K; Otsuka G; Nosé Y
    Artif Organs; 1997 Dec; 21(12):1292-6. PubMed ID: 9423982
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hemolytic characteristics of a pivot bearing supported Gyro centrifugal pump (C1E3) simulating various clinical applications.
    Takami Y; Makinouchi K; Nakazawa T; Benkowski R; Glueck J; Ohara Y; Nosé Y
    Artif Organs; 1996 Sep; 20(9):1042-9. PubMed ID: 8864026
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of surface roughness on hemolysis in a pivot bearing supported Gyro centrifugal pump (C1E3).
    Takami Y; Makinouchi K; Nakazawa T; Glueck J; Benkowski R; Nosé Y
    Artif Organs; 1996 Nov; 20(11):1155-61. PubMed ID: 8908324
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hydraulic assessment of the floating impeller phenomena in a centrifugal pump.
    Nakazawa T; Takami Y; Makinouchi K; Benkowski R; Glueck J; Damm G; Nosé Y
    Artif Organs; 1997 Jan; 21(1):78-82. PubMed ID: 9012911
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Material of the double pivot bearing system in the Gyro C1E3 centrifugal pump.
    Takami Y; Nakazawa T; Makinouchi K; Benkowski R; Glueck J; Nosé Y
    Artif Organs; 1997 Feb; 21(2):143-7. PubMed ID: 9028497
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of the impeller-driver magnetic coupling distance on hemolysis in a compact centrifugal pump.
    Nakazawa T; Makinouchi K; Takami Y; Glueck J; Takatani S; Nosé Y
    Artif Organs; 1996 Mar; 20(3):252-7. PubMed ID: 8694696
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the wear of the pivot bearing in the Gyro C1E3 pump.
    Makinouchi K; Nakazawa T; Takami Y; Takatani S; Nosé Y
    Artif Organs; 1996 Jun; 20(6):523-8. PubMed ID: 8817949
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of the Gyro C1E3 and BioMedicus centrifugal pump performances during cardiopulmonary bypass.
    Nakazawa T; Takami Y; Makinouchi K; Gay J; Taylor D; Ueyama K; Ohashi Y; Kawahito K; Tayama E; Glueck J; Nosé Y
    Artif Organs; 1997 Jul; 21(7):782-5. PubMed ID: 9212958
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pump power loss and heat generation in a pivot bearing-supported Gyro centrifugal pump (C1E3).
    Takami Y; Nakazawa T; Makinouchi K; Glueck J; Ohara Y; Benkowski RJ; Nosé Y
    Artif Organs; 1996 Jul; 20(7):794-7. PubMed ID: 8828770
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The hemolysis test of the Gyro C1E3 pump in pulsatile mode.
    Tayama E; Nakazawa T; Takami Y; Makinouchi K; Ohtsubo S; Ohashi Y; Andrade AJ; Glueck J; Mueller J; Nosé Y
    Artif Organs; 1997 Jul; 21(7):675-9. PubMed ID: 9304391
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hemolytic effects of surface roughness of a pump housing in a centrifugal blood pump.
    Takami Y; Nakazawa T; Makinouchi K; Glueck J; Benkowski R; Nosé Y
    Artif Organs; 1997 May; 21(5):428-32. PubMed ID: 9129778
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Feasibility of a tiny Gyro centrifugal pump as an implantable ventricular assist device.
    Yoshikawa M; Nakata K; Ohtsuka G; Takano T; Glueck J; Fujisawa A; Makinouchi K; Yokokawa M; Nosé Y
    Artif Organs; 1999 Aug; 23(8):774-9. PubMed ID: 10463506
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the Wear of the Pivot Bearing in the Gyro C1E3 Pump.
    Makinouchi K; Nakazawa T; Takami Y; Takatani S; Nose Y
    Artif Organs; 1996 May; 20(5):523-528. PubMed ID: 28868726
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of surface roughness on hemolysis in a centrifugal blood pump.
    Takami Y; Nakazawa T; Makinouchi K; Glueck J; Benkowski R; Nosé Y
    ASAIO J; 1996; 42(5):M858-62. PubMed ID: 8945006
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mapping of pump efficiency on the pressure-flow curve of a centrifugal blood pump.
    Takami Y; Nakazawa T; Makinouchi K; Glueck J; Benkowski R; Nosé Y
    Artif Organs; 1997 Aug; 21(8):953-7. PubMed ID: 9247186
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Modification of a pivot bearing system on a compact centrifugal pump.
    Nakazawa T; Makinouchi K; Takami Y; Glueck J; Takatani S; Nosé Y
    Artif Organs; 1996 Mar; 20(3):258-63. PubMed ID: 8694697
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hemolytic effect of surface roughness of an impeller in a centrifugal blood pump.
    Takami Y; Nakazawa T; Makinouchi K; Tayama E; Glueck J; Benkowski R; Nosé Y
    Artif Organs; 1997 Jul; 21(7):686-90. PubMed ID: 9212939
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of floating impeller phenomena in a Gyro centrifugal pump.
    Nishimura I; Ichikawa S; Mikami M; Ishitoya H; Motomura T; Kawamura M; Linneweber J; Glueck J; Shinohara T; Nosé Y
    Biomed Mater Eng; 2013; 23(1-2):49-55. PubMed ID: 23442236
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Particles released from the Gyro C1E3 during simulated extracorporeal circulation.
    Takano T; Nakata K; Schulte-Eistrup S; Kawahito S; Glueck J; Clarke IC; Williams PA; Maeda T; Nonaka K; Linneweber J; Yoshikawa M; Fujisawa A; Makinouchi K; Yokokawa M; Nosé Y
    Artif Organs; 2000 Jun; 24(6):446-9. PubMed ID: 10886063
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.