These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 8833080)

  • 1. Cavitation dynamics of medtronic hall mechanical heart valve prosthesis: fluid squeezing effect.
    Lee CS; Chandran KB; Chen LD
    J Biomech Eng; 1996 Feb; 118(1):97-105. PubMed ID: 8833080
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cavitation dynamics of mechanical heart valve prostheses.
    Lee CS; Chandran KB; Chen LD
    Artif Organs; 1994 Oct; 18(10):758-67. PubMed ID: 7832658
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of valve holder flexibility on cavitation initiation with mechanical heart valve prostheses: an in vitro study.
    Lee CS; Aluri S; Chandran KB
    J Heart Valve Dis; 1996 Jan; 5(1):104-13. PubMed ID: 8834733
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pressure field in the vicinity of mechanical valve occluders at the instant of valve closure: correlation with cavitation initiation.
    Chandran KB; Lee CS; Chen LD
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S65-75; discussion S75-6. PubMed ID: 8061871
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mechanical valve closing dynamics: relationship between velocity of closing, pressure transients, and cavitation initiation.
    Chandran KB; Aluri S
    Ann Biomed Eng; 1997; 25(6):926-38. PubMed ID: 9395039
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transient pressure at closing of a monoleaflet mechanical heart valve prosthesis: mounting compliance effect.
    Wu ZJ; Gao BZ; Hwang NH
    J Heart Valve Dis; 1995 Sep; 4(5):553-67. PubMed ID: 8581200
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Observation of cavitation in a mechanical heart valve in a total artificial heart.
    Lee H; Tsukiya T; Homma A; Kamimura T; Takewa Y; Nishinaka T; Tatsumi E; Taenaka Y; Takano H; Kitamura S
    ASAIO J; 2004; 50(3):205-10. PubMed ID: 15171470
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cavitation phenomenon in monoleaflet mechanical heart valves with electrohydraulic total artificial heart.
    Lee H; Taenaka Y; Kitamura S
    Int J Artif Organs; 2004 Sep; 27(9):779-86. PubMed ID: 15521218
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanisms of mechanical heart valve cavitation: investigation using a tilting disk valve model.
    He Z; Xi B; Zhu K; Hwang NH
    J Heart Valve Dis; 2001 Sep; 10(5):666-74. PubMed ID: 11603607
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mitral heart valve cavitation in an artificial heart environment.
    Sneckenberger DS; Stinebring DR; Deutsch S; Geselowitz DB; Tarbell JM
    J Heart Valve Dis; 1996 Mar; 5(2):216-27. PubMed ID: 8665017
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Observation of cavitation bubbles in monoleaflet mechanical heart valves.
    Lee H; Tsukiya T; Homma A; Kamimura T; Takewa Y; Tatsumi E; Taenaka Y; Takano H; Kitamura S
    J Artif Organs; 2004; 7(3):121-7. PubMed ID: 15558332
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of the cavitation potential of prosthetic heart valves based on valve closing dynamics.
    Zapanta CM; Stinebring DR; Deutsch S; Geselowitz DB; Tarbell JM
    J Heart Valve Dis; 1998 Nov; 7(6):655-67. PubMed ID: 9870200
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis.
    Bluestein D; Einav S; Hwang NH
    J Biomech; 1994 Nov; 27(11):1369-78. PubMed ID: 7798287
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bubble observation and transient pressure signals in mechanical heart valve cavitation study.
    Lijun X; Hock YJ; Hwang NH
    J Heart Valve Dis; 2003 Mar; 12(2):235-44. PubMed ID: 12701797
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of structural compliance on cavitation threshold measurement of mechanical heart valves.
    Guo GX; Adlparvar P; Howanec M; Roy J; Kafesjian R; Kingsbury C
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S77-83; discussion S83-4. PubMed ID: 8061872
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mechanism for cavitation in the mechanical heart valve with an artificial heart: nuclei and viscosity dependence.
    Lee H; Taenaka Y; Kitamura S
    Artif Organs; 2005 Jan; 29(1):41-6. PubMed ID: 15644082
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Instantaneous back flow through peripheral clearance of Medtronic Hall tilting disc valve at the moment of closure.
    Lee CS; Chandran KB
    Ann Biomed Eng; 1994; 22(4):371-80. PubMed ID: 7998682
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanism for cavitation of monoleaflet and bileaflet valves in an artificial heart.
    Lee H; Tatsumi E; Homma A; Tsukiya T; Taenaka Y
    J Artif Organs; 2006; 9(3):154-60. PubMed ID: 16998700
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A detailed fluid mechanics study of tilting disk mechanical heart valve closure and the implications to blood damage.
    Manning KB; Herbertson LH; Fontaine AA; Deutsch S
    J Biomech Eng; 2008 Aug; 130(4):041001. PubMed ID: 18601443
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Closing behavior of the mechanical heart valve in a total artificial heart.
    Lee HS; Tsukiya T; Homma A; Taenaka Y; Tatsumi E; Takano H
    J Artif Organs; 2003; 6(1):37-41. PubMed ID: 14598123
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.