These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
138 related articles for article (PubMed ID: 8834689)
1. Relative efficacy of different tilts with biphasic defibrillation in humans. Natale A; Sra J; Krum D; Dhala A; Deshpande S; Jazayeri M; Newby K; Wase A; Axtell K; VanHout WL; Akhtar M Pacing Clin Electrophysiol; 1996 Feb; 19(2):197-206. PubMed ID: 8834689 [TBL] [Abstract][Full Text] [Related]
2. Comparison of biphasic and monophasic pulses: does the advantage of biphasic shocks depend on the waveshape? Natale A; Sra J; Krum D; Dhala A; Deshpande S; Jazayeri M; Axtell K; Degroot P; VanHout WL; Akhtar M Pacing Clin Electrophysiol; 1995 Jul; 18(7):1354-61. PubMed ID: 7567587 [TBL] [Abstract][Full Text] [Related]
3. Combination biphasic waveform plus sequential pulse defibrillation improves defibrillation efficacy of a nonthoracotomy lead system. Exner D; Yee R; Jones DL; Klein GJ; Mehra R J Am Coll Cardiol; 1994 Feb; 23(2):317-22. PubMed ID: 8294680 [TBL] [Abstract][Full Text] [Related]
4. Defibrillation efficacy of commercially available biphasic impulses in humans. Importance of negative-phase peak voltage. Tomassoni G; Newby K; Deshpande S; Axtell K; Sra J; Akhtar M; Natale A Circulation; 1997 Apr; 95(7):1822-6. PubMed ID: 9107169 [TBL] [Abstract][Full Text] [Related]
5. Biphasic defibrillation using a single capacitor with large capacitance: reduction of peak voltages and ICD device size. Block M; Hammel D; Böcker D; Borggrefe M; Budde T; Isbruch F; Scheld HH; Breithardt G Pacing Clin Electrophysiol; 1996 Feb; 19(2):207-14. PubMed ID: 8834690 [TBL] [Abstract][Full Text] [Related]
6. Optimization of biphasic waveforms for human nonthoracotomy defibrillation. Swartz JF; Fletcher RD; Karasik PE Circulation; 1993 Dec; 88(6):2646-54. PubMed ID: 8252675 [TBL] [Abstract][Full Text] [Related]
7. Prospective randomized comparison of 65%/65% versus 42%/42% tilt biphasic waveform on defibrillation thresholds in humans. Shepard RK; DeGroot PJ; Pacifico A; Wood MA; Ellenbogen KA J Interv Card Electrophysiol; 2003 Jun; 8(3):221-5. PubMed ID: 12815309 [TBL] [Abstract][Full Text] [Related]
8. Truncated biphasic pulses for transthoracic defibrillation. Bardy GH; Gliner BE; Kudenchuk PJ; Poole JE; Dolack GL; Jones GK; Anderson J; Troutman C; Johnson G Circulation; 1995 Mar; 91(6):1768-74. PubMed ID: 7882486 [TBL] [Abstract][Full Text] [Related]
9. Low-tilt monophasic and biphasic waveforms compared with standard biphasic waveforms in the transvenous defibrillation of ventricular fibrillation. Bennett JR; Darragh KM; Walsh SJ; Allen DJ; Scott M; Stevenson M; Adgey JA; Anderson JM; Manoharan G Pacing Clin Electrophysiol; 2014 Mar; 37(3):279-89. PubMed ID: 24102186 [TBL] [Abstract][Full Text] [Related]
10. Prospective randomized comparison of biphasic waveform tilt using a unipolar defibrillation system. Poole JE; Bardy GH; Kudenchuk PJ; Dolack GL; Raitt MH; Mehra R; Johnson G Pacing Clin Electrophysiol; 1995 Jul; 18(7):1369-73. PubMed ID: 7567589 [TBL] [Abstract][Full Text] [Related]
11. Prospective, randomized comparison in humans of a unipolar defibrillation system with that using an additional superior vena cava electrode. Bardy GH; Dolack GL; Kudenchuk PJ; Poole JE; Mehra R; Johnson G Circulation; 1994 Mar; 89(3):1090-3. PubMed ID: 8124794 [TBL] [Abstract][Full Text] [Related]
12. Transvenous biventricular defibrillation. Meisel E; Butter C; Philippon F; Higgins S; Strickberger SA; Smith J; Hahn S; Michel U; Schubert B; Pfeiffer D Am J Cardiol; 2000 Nov; 86(9A):76K-85K. PubMed ID: 11084104 [TBL] [Abstract][Full Text] [Related]
13. A prospective, randomized, comparison in patients between a pectoral unipolar defibrillation system and that using an additional inferior vena cava electrode. Favale S; Dicandia CD; Tunzi P; Rizzon P Pacing Clin Electrophysiol; 1999 Aug; 22(8):1140-5. PubMed ID: 10461288 [TBL] [Abstract][Full Text] [Related]
14. Effect of first-phase polarity of biphasic shocks on defibrillation threshold with a single transvenous lead system. Strickberger SA; Man KC; Daoud E; Neary MP; Horwood LE; Niebauer M; Hummel JD; Morady F J Am Coll Cardiol; 1995 Jun; 25(7):1605-8. PubMed ID: 7759712 [TBL] [Abstract][Full Text] [Related]
15. Increase in defibrillation threshold in non-thoracotomy implantable defibrillators using a biphasic waveform. Martin DT; John R; Venditti FJ Am J Cardiol; 1995 Aug; 76(4):263-6. PubMed ID: 7618621 [TBL] [Abstract][Full Text] [Related]
16. Achieving sufficient safety margins with fixed duration waveforms and the use of multiple time constants. Keane D; Aweh N; Hynes B; Sheahan RG; Cripps T; Bashir Y; Zaidi A; Fahy G; Lowe M; Doherty P; Kroll MK Pacing Clin Electrophysiol; 2007 May; 30(5):596-602. PubMed ID: 17461867 [TBL] [Abstract][Full Text] [Related]
18. Acute defibrillation performance of a novel, non-transvenous shock pathway in adult ICD indicated patients. Lieberman R; Havel WJ; Rashba E; DeGroot PJ; Stromberg K; Shorofsky SR Heart Rhythm; 2008 Jan; 5(1):28-34. PubMed ID: 18053770 [TBL] [Abstract][Full Text] [Related]
19. Effect of biphasic waveform pulse on endocardial defibrillation efficacy in humans. Neuzner J; Pitschner HF; Huth C; Schlepper M Pacing Clin Electrophysiol; 1994 Feb; 17(2):207-12. PubMed ID: 7513406 [TBL] [Abstract][Full Text] [Related]
20. Preliminary experience with a hybrid nonthoracotomy defibrillating system that includes a biphasic device: comparison with a standard monophasic device using the same lead system. Natale A; Sra J; Axtell K; Maglio C; Dhala A; Deshpande S; Jazayeri M; Wase A; Akhtar M J Am Coll Cardiol; 1994 Aug; 24(2):406-12. PubMed ID: 8034875 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]