These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 8836842)

  • 21. In vivo behaviour of hydroxyapatite coatings on titanium implants: a quantitative study in the rabbit.
    Darimont GL; Cloots R; Heinen E; Seidel L; Legrand R
    Biomaterials; 2002 Jun; 23(12):2569-75. PubMed ID: 12033605
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants.
    Inadome T; Hayashi K; Nakashima Y; Tsumura H; Sugioka Y
    J Biomed Mater Res; 1995 Jan; 29(1):19-24. PubMed ID: 7713954
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of tissue reaction and osteointegration of metal implants between hydroxyapatite/Ti alloy coat: an animal experimental study.
    Itiravivong P; Promasa A; Laiprasert T; Techapongworachai T; Kuptniratsaikul S; Thanakit V; Heimann RB
    J Med Assoc Thai; 2003 Jun; 86 Suppl 2():S422-31. PubMed ID: 12930020
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs.
    Søballe K; Brockstedt-Rasmussen H; Hansen ES; Bünger C
    Acta Orthop Scand; 1992 Apr; 63(2):128-40. PubMed ID: 1590045
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Characterization of the interface in the plasma-sprayed HA coating/Ti-6Al-4V implant system.
    Filiaggi MJ; Coombs NA; Pilliar RM
    J Biomed Mater Res; 1991 Oct; 25(10):1211-29. PubMed ID: 1667401
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Intramedullary implant of plasma-sprayed hydroxyapatite coating: an interface study.
    Yang CY; Wang BC; Lee TM; Chang E; Chang GL
    J Biomed Mater Res; 1997 Jul; 36(1):39-48. PubMed ID: 9212387
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Osseointegration of a hydroxyapatite-coated multilayered mesh stem.
    Kusakabe H; Sakamaki T; Nihei K; Oyama Y; Yanagimoto S; Ichimiya M; Kimura J; Toyama Y
    Biomaterials; 2004 Jul; 25(15):2957-69. PubMed ID: 14967528
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of plasma-sprayed hydroxyapatite coatings and zirconia-reinforced hydroxyapatite composite coatings: in vivo study.
    Lee TM; Yang CY; Chang E; Tsai RS
    J Biomed Mater Res A; 2004 Dec; 71(4):652-60. PubMed ID: 15505828
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Interfacial shear strength and histology of plasma sprayed and sintered hydroxyapatite implants in vivo.
    Wang S; Lacefield WR; Lemons JE
    Biomaterials; 1996 Oct; 17(20):1945-70. PubMed ID: 8894089
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Tensile tests of interface between bone and plasma-sprayed HA coating-titanium implant.
    Lin H; Xu H; Zhang X; de Groot K
    J Biomed Mater Res; 1998; 43(2):113-22. PubMed ID: 9619429
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Implant-delivered Alendronate Causes a Dose-dependent Response on Net Bone Formation Around Porous Titanium Implants in Canines.
    Pura JA; Bobyn JD; Tanzer M
    Clin Orthop Relat Res; 2016 May; 474(5):1224-33. PubMed ID: 26831478
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Histomorphometry of hydroxyapatite coated and uncoated porous titanium bone implants.
    Moroni A; Caja VL; Egger EL; Trinchese L; Chao EY
    Biomaterials; 1994 Sep; 15(11):926-30. PubMed ID: 7833442
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Evaluation of the titanium Ti-6Al-7Nb alloy with and without plasma-sprayed hydroxyapatite coating on growth and viability of cultured osteoblast-like cells.
    de Lavos-Valereto IC; Deboni MC; Azambuja N; Marques MM
    J Periodontol; 2002 Aug; 73(8):900-5. PubMed ID: 12211500
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The effect of substrate roughness and hydroxyapatite coating thickness on implant shear strength.
    Svehla M; Morberg P; Bruce W; Zicat B; Walsh WR
    J Arthroplasty; 2002 Apr; 17(3):304-11. PubMed ID: 11938506
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of titanium plasma-sprayed and plasma-sprayed hydroxyapatite implants in vivo.
    Ong JL; Carnes DL; Bessho K
    Biomaterials; 2004 Aug; 25(19):4601-6. PubMed ID: 15120505
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Hydroxyapatite coating enhances fixation of porous coated implants. A comparison in dogs between press fit and noninterference fit.
    Søballe K; Hansen ES; Brockstedt-Rasmussen H; Pedersen CM; Bünger C
    Acta Orthop Scand; 1990 Aug; 61(4):299-306. PubMed ID: 2402977
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Mechanical and histological fixation of hydroxylapatite-coated pyrolytic carbon and titanium alloy implants: a report of short-term results.
    Hetherington VJ; Lord CE; Brown SA
    J Appl Biomater; 1995; 6(4):243-8. PubMed ID: 8589509
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Early bone apposition in vivo on plasma-sprayed and electrochemically deposited hydroxyapatite coatings on titanium alloy.
    Wang H; Eliaz N; Xiang Z; Hsu HP; Spector M; Hobbs LW
    Biomaterials; 2006 Aug; 27(23):4192-203. PubMed ID: 16618502
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A mechanical investigation of fluorapatite, magnesiumwhitlockite, and hydroxylapatite plasma-sprayed coatings in goats.
    Dhert WJ; Klein CP; Wolke JG; van der Velde EA; de Groot K; Rozing PM
    J Biomed Mater Res; 1991 Oct; 25(10):1183-200. PubMed ID: 1667400
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Gap healing enhanced by hydroxyapatite coating in dogs.
    Søballe K; Hansen ES; Brockstedt-Rasmussen H; Hjortdal VE; Juhl GI; Pedersen CM; Hvid I; Bünger C
    Clin Orthop Relat Res; 1991 Nov; (272):300-7. PubMed ID: 1657476
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.