85 related articles for article (PubMed ID: 8837664)
1. Receiver-operating characteristic (ROC) curves: a fundamental tool for improving the clinical usefulness of in vitro IgE tests.
Plebani M; Borghesan F; Basso D; Faggian D
Allergy; 1996 Jun; 51(6):407-11. PubMed ID: 8837664
[TBL] [Abstract][Full Text] [Related]
2. Clinical evaluation of a new quantitative method for specific IgE antibodies.
Plebani M; Borghesan F; Bernardi D; Faggian D
Eur J Clin Chem Clin Biochem; 1996 Jul; 34(7):579-84. PubMed ID: 8864410
[TBL] [Abstract][Full Text] [Related]
3. Analysis of skin testing and serum-specific immunoglobulin E to predict airway reactivity to cat allergens.
Fernández C; Cárdenas R; Martín D; Garcimartín M; Romero S; de la Cámara AG; Vives R
Clin Exp Allergy; 2007 Mar; 37(3):391-9. PubMed ID: 17359389
[TBL] [Abstract][Full Text] [Related]
4. Multicentre evaluation of Capture Assay Radim Liquid Allergen for measurement of specific IgE antibodies.
Banfi G; Ferrara F; Bonini P; Colombo G; Plebani M; Borghesan F; Faggian D; Caputo M; Andri L; Senna GE
Eur J Clin Chem Clin Biochem; 1995 Oct; 33(10):755-9. PubMed ID: 8608200
[TBL] [Abstract][Full Text] [Related]
5. The performance of a component-based allergen-microarray in clinical practice.
Wöhrl S; Vigl K; Zehetmayer S; Hiller R; Jarisch R; Prinz M; Stingl G; Kopp T
Allergy; 2006 May; 61(5):633-9. PubMed ID: 16629796
[TBL] [Abstract][Full Text] [Related]
6. Influence of total serum IgE levels on the in vitro detection of beta-lactams-specific IgE antibodies.
Vultaggio A; Matucci A; Virgili G; Rossi O; Filì L; Parronchi P; Romagnani S; Maggi E
Clin Exp Allergy; 2009 Jun; 39(6):838-44. PubMed ID: 19400911
[TBL] [Abstract][Full Text] [Related]
7. Comparison between two automated systems to determine specific IgE: CAP and ELItest.
Brunnée T; Seeberger A; Kleine-Tebbe J; Kunkel G
Clin Exp Allergy; 1996 Dec; 26(12):1420-7. PubMed ID: 9027443
[TBL] [Abstract][Full Text] [Related]
8. Accuracy of ImmunoCAP Rapid in the diagnosis of allergic sensitization in children between 1 and 14 years with recurrent wheezing: the IReNE study.
Diaz-Vazquez C; Torregrosa-Bertet MJ; Carvajal-Urueña I; Cano-Garcinuño A; Fos-Escrivà E; García-Gallego A; López-Cacho F; Monzón-Fueyo MC; Pérez-Porcuna XM; Ridao-Redondo ML
Pediatr Allergy Immunol; 2009 Sep; 20(6):601-9. PubMed ID: 19220775
[TBL] [Abstract][Full Text] [Related]
9. Comparative evaluation of the pharmacia CAP system and the DPC AlaSTAT system for in vitro detection of allergen-specific IgE with the skin prick test.
van Houte AJ; Bartels PC
Eur J Clin Chem Clin Biochem; 1992 Feb; 30(2):101-5. PubMed ID: 1581409
[TBL] [Abstract][Full Text] [Related]
10. [A novel diagnostic method for allergy "LUCICA HRT"].
Yamakoshi M; Fujii Y; Nagai H; Ohyama K
Rinsho Byori; 1997 Feb; 45(2):163-73. PubMed ID: 9121001
[TBL] [Abstract][Full Text] [Related]
11. [Specific skin reactions induced by individual pollen preparations in hypersensitivity persons].
Paranos S; Petrović S; Vojović I
Srp Arh Celok Lek; 1998; 126(9-10):362-7. PubMed ID: 9863408
[TBL] [Abstract][Full Text] [Related]
12. Clinical efficiency of in vitro and in vivo tests for allergic diseases.
Plebani M; Borghesan F; Faggian D
Ann Allergy Asthma Immunol; 1995 Jan; 74(1):23-8. PubMed ID: 7719878
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of serum s-IgE/total IgE ratio in predicting clinical response to allergen-specific immunotherapy.
Di Lorenzo G; Mansueto P; Pacor ML; Rizzo M; Castello F; Martinelli N; Ditta V; Lo Bianco C; Leto-Barone MS; D'Alcamo A; Di Fede G; Rini GB; Ditto AM
J Allergy Clin Immunol; 2009 May; 123(5):1103-10, 1110.e1-4. PubMed ID: 19356792
[TBL] [Abstract][Full Text] [Related]
14. Sensitivity and specificity of recombinant omega-5 gliadin-specific IgE measurement for the diagnosis of wheat-dependent exercise-induced anaphylaxis.
Matsuo H; Dahlström J; Tanaka A; Kohno K; Takahashi H; Furumura M; Morita E
Allergy; 2008 Feb; 63(2):233-6. PubMed ID: 18186814
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of the luciferase assay-based in vitro elicitation test for serum IgE.
Nakamura R; Ishiwatari A; Higuchi M; Uchida Y; Nakamura R; Kawakami H; Urisu A; Teshima R
Allergol Int; 2012 Sep; 61(3):431-7. PubMed ID: 22722812
[TBL] [Abstract][Full Text] [Related]
16. Comparison of VIDAS Stallertest and Pharmacia CAP assays for detection of specific IgE antibodies in allergic children.
Sohn MH; Lee SY; Lee KE; Kim KE
Ann Clin Lab Sci; 2005; 35(3):318-22. PubMed ID: 16081590
[TBL] [Abstract][Full Text] [Related]
17. [Evaluation of the value of 2 methods for measuring levels of allergen specific IgE antibodies in serum--Phadebas RAST I immuno CAP System].
Jamrozik K
Pneumonol Alergol Pol; 2001; 69(1-2):33-9. PubMed ID: 11475556
[TBL] [Abstract][Full Text] [Related]
18. [Interleukin 4, total and allergen-specific immunoglobulin E antibodies in the blood of individuals with an atopic constitution].
Paranos S; Pravica V; Bonaci B; Stojković-Mostarica M
Srp Arh Celok Lek; 1998; 126(3-4):92-6. PubMed ID: 9863362
[TBL] [Abstract][Full Text] [Related]
19. Allergen-specific IgE measurement with the IMMULITE 2000 system: intermethod comparison of detection performance for allergen-specific IgE antibodies from Korean allergic patients.
Lee YW; Sohn JH; Lee JH; Hong CS; Park JW
Clin Chim Acta; 2009 Mar; 401(1-2):25-32. PubMed ID: 19056369
[TBL] [Abstract][Full Text] [Related]
20. ImmunoCAP Phadiatop Infant--a new blood test for detecting IgE sensitisation in children at 2 years of age.
Ballardini N; Nilsson C; Nilsson M; Lilja G
Allergy; 2006 Mar; 61(3):337-43. PubMed ID: 16436143
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]