These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 8839421)

  • 21. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).
    Tedgren AC; Hedman A; Grindborg JE; Carlsson GA
    Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A semianalytic model to investigate the potential applications of x-ray scatter imaging.
    Leclair RJ; Johns PC
    Med Phys; 1998 Jun; 25(6):1008-20. PubMed ID: 9650191
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Quantum noise in detectors.
    Rimkus D; Baily NA
    Med Phys; 1983; 10(4):470-1. PubMed ID: 6888360
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Image noise in X-ray imaging caused by radiation scattering and source leakage, a qualitative and quantitative analysis.
    Hammersberg P; Stenström M; Hedtjärn H; Mångård M
    J Xray Sci Technol; 1998 Jan; 8(1):19-29. PubMed ID: 22388424
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Light production from intensifying screens (theoretical and experimental aspects)].
    Giacomich R; Tomasini F; Bacarini L; Di Lelio A
    Radiol Med; 1982; 68(7-8):571-80. PubMed ID: 7134508
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Computer simulation of broad-beam and narrow-beam attenuation in lead for diagnostic x-ray energies.
    McLean D
    Med Phys; 1993; 20(5):1549-54. PubMed ID: 8289739
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Determination of the KQclinfclin,Qmsr fmsr correction factors for detectors used with an 800 MU/min CyberKnife(®) system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method.
    Moignier C; Huet C; Makovicka L
    Med Phys; 2014 Jul; 41(7):071702. PubMed ID: 24989371
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Photon counting multienergy x-ray imaging: effect of the characteristic x rays on detector performance.
    Shikhaliev PM; Fritz SG; Chapman JW
    Med Phys; 2009 Nov; 36(11):5107-19. PubMed ID: 19994521
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Calculation of absorbed dose ratios using correlated Monte Carlo sampling.
    Ma CM; Nahum AE
    Med Phys; 1993; 20(4):1189-99. PubMed ID: 8413029
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Monte Carlo calculation of the sensitivity of a commercial dose calibrator to gamma and beta radiation.
    Laedermann JP; Valley JF; Bulling S; Bochud FO
    Med Phys; 2004 Jun; 31(6):1614-22. PubMed ID: 15259666
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Non-reference condition correction factor kNR of typical radiation detectors applied for the dosimetry of high-energy photon fields in radiotherapy.
    Chofor N; Harder D; Poppe B
    Z Med Phys; 2012 Sep; 22(3):181-96. PubMed ID: 22658451
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Dosimetric characterization of radiosurgical beams with a diamond detector.
    Rustgi SN; Frye DM
    Med Phys; 1995 Dec; 22(12):2117-21. PubMed ID: 8746721
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Monte Carlo optimization of metal/phosphor screens at megavoltage energies.
    Radcliffe T; Barnea G; Wowk B; Rajapakshe R; Shalev S
    Med Phys; 1993; 20(4):1161-9. PubMed ID: 8413026
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators.
    Beddar AS; Briere TM; Mourtada FA; Vassiliev ON; Liu HH; Mohan R
    Med Phys; 2005 May; 32(5):1265-9. PubMed ID: 15984678
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Two-effective-source method for the calculation of in-air output at various source-to-detector distances in wedged fields.
    Kim S; Liu C; Chen C; Palta JR
    Med Phys; 1999 Jun; 26(6):949-55. PubMed ID: 10436896
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The use of an electronic portal imaging system to measure portal dose and portal dose profiles.
    Parsaei H; el-Khatib E; Rajapakshe R
    Med Phys; 1998 Oct; 25(10):1903-9. PubMed ID: 9800697
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Characterization of optical transport effects on EPID dosimetry using Geant4.
    Blake SJ; Vial P; Holloway L; Greer PB; McNamara AL; Kuncic Z
    Med Phys; 2013 Apr; 40(4):041708. PubMed ID: 23556878
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Dual energy radiography using X-ray films and intensifying screens.
    Zananiri FA; Speller RD
    J Biomed Eng; 1990 May; 12(3):239-47. PubMed ID: 2348713
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Scattered radiation in scanning slot mammography.
    Jing Z; Huda W; Walker JK
    Med Phys; 1998 Jul; 25(7 Pt 1):1111-7. PubMed ID: 9682196
    [TBL] [Abstract][Full Text] [Related]  

  • 40. In phantom determination of collimator scatter factor.
    Lam KL; Ten Haken RK
    Med Phys; 1996 Jul; 23(7):1207-12. PubMed ID: 8839414
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.