These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. Quantification of furosemide from serum and tissues using high-performance liquid chromatography. Mills CD; Whitworth C; Rybak LP; Henley CM J Chromatogr B Biomed Sci Appl; 1997 Nov; 701(1):65-70. PubMed ID: 9389339 [TBL] [Abstract][Full Text] [Related]
24. Rapid UHPLC method for simultaneous determination of vancomycin, terbinafine, spironolactone, furosemide and their metabolites: application to human plasma and urine. Baranowska I; Wilczek A; Baranowski J Anal Sci; 2010; 26(7):755-9. PubMed ID: 20631435 [TBL] [Abstract][Full Text] [Related]
25. Determination of a new oral cephalosporin, S-1090, in human plasma and urine by direct injection high-performance liquid chromatography with ultraviolet detection and column switching. Fujitomo H; Nagaoka T; Nishino I; Umeda T J Chromatogr B Biomed Sci Appl; 1999 May; 728(1):125-31. PubMed ID: 10379664 [TBL] [Abstract][Full Text] [Related]
26. Simultaneous determination of palladium, platinum, rhodium and gold by on-line solid phase extraction and high performance liquid chromatography with 5-(2-hydroxy-5-nitrophenylazo)thiorhodanine as pre-column derivatization regents. Hu Q; Yang X; Huang Z; Chen J; Yang G J Chromatogr A; 2005 Nov; 1094(1-2):77-82. PubMed ID: 16257292 [TBL] [Abstract][Full Text] [Related]
27. Automated analysis of fluvoxamine in rat plasma using a column-switching system and ion-pair high-performance liquid chromatography. Liu S; Shinkai N; Kakubari I; Saitoh H; Noguchi K; Saitoh T; Yamauchi H Biomed Chromatogr; 2008 Dec; 22(12):1442-9. PubMed ID: 18655223 [TBL] [Abstract][Full Text] [Related]
28. Simultaneous determination of estriol and estriol 3-sulfate in serum by column-switching semi-micro high-performance liquid chromatography with ultraviolet and electrochemical detection. Tagawa N; Tsuruta H; Fujinami A; Kobayashi Y J Chromatogr B Biomed Sci Appl; 1999 Feb; 723(1-2):39-45. PubMed ID: 10080631 [TBL] [Abstract][Full Text] [Related]
29. Simultaneous analysis of dehydroacetic acid, benzoic acid, sorbic acid and salicylic acid in cosmetic products by solid-phase extraction and high-performance liquid chromatography. Mikami E; Goto T; Ohno T; Matsumoto H; Nishida M J Pharm Biomed Anal; 2002 Apr; 28(2):261-7. PubMed ID: 11929668 [TBL] [Abstract][Full Text] [Related]
30. A monolithic-phase based on-line extraction approach for determination of pharmaceutical components in human plasma by HPLC-MS/MS and a comparison with liquid-liquid extraction. Naxing Xu R; Fan L; Kim GE; El-Shourbagy TA J Pharm Biomed Anal; 2006 Feb; 40(3):728-36. PubMed ID: 16289933 [TBL] [Abstract][Full Text] [Related]
31. Quantitation of efletirizine in human plasma and urine using automated solid-phase extraction and column-switching high-performance liquid chromatography. Coe RA; DeCesare LS; Lee JW J Chromatogr B Biomed Sci Appl; 1999 Jul; 730(2):239-47. PubMed ID: 10448959 [TBL] [Abstract][Full Text] [Related]
32. Direct injection of plasma to determine pseudoephedrine by high performance liquid chromatography with column switching. Guo P; Li Z; Li T; Wang X; Li F Biomed Chromatogr; 1999 Feb; 13(1):61-4. PubMed ID: 10191946 [TBL] [Abstract][Full Text] [Related]
33. Carbonic anhydrase-immobilized precolumn for selective on-line sample pretreatment in high-performance liquid chromatographic determination of certain sulphonamide drugs. Ohta T; Takamiya I; Takitani S Biomed Chromatogr; 1994; 8(4):184-8. PubMed ID: 7812123 [TBL] [Abstract][Full Text] [Related]
34. High-performance liquid chromatography determination of flunitrazepam and its metabolites in plasma by use of column-switching technique: comparison of two extraction columns. El Mahjoub A; Staub C J Chromatogr B Biomed Sci Appl; 2001 Apr; 754(2):271-83. PubMed ID: 11339271 [TBL] [Abstract][Full Text] [Related]
35. Quantitative determination of endogenous retinoids in mouse embryos by high-performance liquid chromatography with on-line solid-phase extraction, column switching and electrochemical detection. Sakhi AK; Gundersen TE; Ulven SM; Blomhoff R; Lundanes E J Chromatogr A; 1998 Dec; 828(1-2):451-60. PubMed ID: 9916324 [TBL] [Abstract][Full Text] [Related]
36. Determination of metformin in human plasma by high-performance liquid chromatography. Amini H; Ahmadiani A; Gazerani P J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Sep; 824(1-2):319-22. PubMed ID: 16043427 [TBL] [Abstract][Full Text] [Related]
37. Determination of neotame in beverages, cakes and preserved fruits by column-switching high-performance liquid chromatography. Yang D; Chen B Food Addit Contam Part A Chem Anal Control Expo Risk Assess; 2010 Sep; 27(9):1221-5. PubMed ID: 20526922 [TBL] [Abstract][Full Text] [Related]
38. Development and optimization of simplified LC-MS/MS quantification of 25-hydroxyvitamin D using protein precipitation combined with on-line solid phase extraction (SPE). Thibeault D; Caron N; Djiana R; Kremer R; Blank D J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Feb; 883-884():120-7. PubMed ID: 22265352 [TBL] [Abstract][Full Text] [Related]
39. Determination of diuretics in human urine by hollow fiber-based liquid-liquid-liquid microextraction coupled to high performance liquid chromatography. Zhang Z; Wang D; Zhang L; Du M; Chen G Analyst; 2008 Sep; 133(9):1187-94. PubMed ID: 18709193 [TBL] [Abstract][Full Text] [Related]
40. Determination of losartan, telmisartan, and valsartan by direct injection of human urine into a column-switching liquid chromatographic system with fluorescence detection. del Rosario Brunetto M; Contreras Y; Clavijo S; Torres D; Delgado Y; Ovalles F; Ayala C; Gallignani M; Estela JM; Martin VC J Pharm Biomed Anal; 2009 Sep; 50(2):194-9. PubMed ID: 19446420 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]