These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
116 related articles for article (PubMed ID: 8846471)
1. New device for wire and catheter capturing: in vivo experiments and first clinical experience. Vorwerk D; Günther RW; Schürmann K; Schmitz-Rode T Cardiovasc Intervent Radiol; 1995; 18(5):312-4. PubMed ID: 8846471 [TBL] [Abstract][Full Text] [Related]
2. A simplified pull-through angioplasty technique without a snare device. A technical note. Matsumoto Y; Nakai K; Tsutsumi M; Iko M; Oishi H; Eto H; Mizokami T; Nii K; Aikawa H; Kazekawa K Interv Neuroradiol; 2013 Jun; 19(2):167-72. PubMed ID: 23693039 [TBL] [Abstract][Full Text] [Related]
3. Percutaneous balloon embolectomy with a self-expanding tulip sheath: in vivo experiments. Vorwerk D; Günther RW; Schürmann K; Schmitz-Rode T; Biesterfeld S Radiology; 1995 Oct; 197(1):153-6. PubMed ID: 7568814 [TBL] [Abstract][Full Text] [Related]
4. Predilation technique with balloon angioplasty to facilitate percutaneous groin access of large size sheath through scar tissue. Pecoraro F; Krishnaswamy M; Steuer J; Puippe G; Mangialardi N; Pfammatter T; Rancic Z; Veith FJ; Cayne NS; Lachat M Vascular; 2017 Aug; 25(4):396-401. PubMed ID: 28068871 [TBL] [Abstract][Full Text] [Related]
5. A modified technique for carotid cannulation via the transfemoral approach, during angioplasty and stent placement. Gupta K; Biria M; Mortazavi A Tex Heart Inst J; 2008; 35(3):286-8. PubMed ID: 18941650 [TBL] [Abstract][Full Text] [Related]
6. The parallel sheath technique in severe iliac tortuosity: a simple and novel technique to improve catheter manoeuvrability. Reifart N; Sotoudeh N EuroIntervention; 2014 Jun; 10(2):231-5. PubMed ID: 24080523 [No Abstract] [Full Text] [Related]
7. [Guidance of interventions in subintimal recanalization and fenestration of dissection membranes using a novel dual-lumen intravascular ultrasound catheter]. Kickuth R; Ludwig KC; Do DD; Husmann M; Baumgartner I; Triller J Rofo; 2006 Sep; 178(9):898-905. PubMed ID: 16921463 [TBL] [Abstract][Full Text] [Related]
8. Endovascular repair of stent graft collapse by stent-protected angioplasty using a femoral-brachial guidewire. Kotelis D; Lopez-Benitez R; von Tengg-Kobligk H; Geisbüsch P; Böckler D J Vasc Surg; 2008 Dec; 48(6):1609-12. PubMed ID: 19118746 [TBL] [Abstract][Full Text] [Related]
9. Retrograde use of the Outback re-entry catheter in complex infrainguinal arterial recanalizations. Patrone L; Dharmarajah B; Korosoglou G; Theivacumar S; Antaredja M; Oberacker R; Tilemann L; Blessing E J Vasc Surg; 2022 Jan; 75(1):177-185.e1. PubMed ID: 34302937 [TBL] [Abstract][Full Text] [Related]
10. Transradial and transbrachial arterial approach for simultaneous carotid angiographic examination and stenting using catheter looping and retrograde engagement technique. Fang HY; Chung SY; Sun CK; Youssef AA; Bhasin A; Tsai TH; Yang CH; Chen CJ; Hussein H; Wu CJ; Yip HK Ann Vasc Surg; 2010 Jul; 24(5):670-9. PubMed ID: 20363587 [TBL] [Abstract][Full Text] [Related]
11. Pull-through approach to percutaneous angioplasty of totally occluded common iliac arteries. Ginsburg R; Thorpe P; Bowles CR; Wright AM; Wexler L Radiology; 1989 Jul; 172(1):111-3. PubMed ID: 2525789 [TBL] [Abstract][Full Text] [Related]
12. Percutaneous embolectomy: in vitro investigations of the self-expanding tulip sheath. Vorwerk D; Guenther RW; Clerc C; Schmitz-Rode T; Imbert C Radiology; 1992 Feb; 182(2):415-8. PubMed ID: 1732959 [TBL] [Abstract][Full Text] [Related]
13. On-Site-Modified Sheath to Overcome the Undesirable Catheterization of the Profunda Femoris Artery During Antegrade Femoral Access. Ysa A; Lobato M; Arruabarrena A; Quintana AM; Gómez R; Ortiz de Salazar L; Metcalfe M; Fonseca JL J Endovasc Ther; 2020 Jun; 27(3):505-508. PubMed ID: 32193967 [No Abstract] [Full Text] [Related]
14. MR-compatible polyetheretherketone-based guide wire assisting MR-guided stenting of iliac and supraaortic arteries in swine: feasibility study. Kos S; Huegli R; Hofmann E; Quick HH; Kuehl H; Aker S; Kaiser GM; Borm PJ; Jacob AL; Bilecen D Minim Invasive Ther Allied Technol; 2009; 18(3):181-8. PubMed ID: 19431070 [TBL] [Abstract][Full Text] [Related]
15. The outback catheter: a new device for true lumen re-entry after dissection during recanalization of arterial occlusions. Hausegger KA; Georgieva B; Portugaller H; Tauss J; Stark G Cardiovasc Intervent Radiol; 2004; 27(1):26-30. PubMed ID: 15109224 [TBL] [Abstract][Full Text] [Related]
16. Transcutaneous ultrasonography can be used to guide and monitor balloon angioplasty. Cluley SR; Brener BJ; Hollier L; Schoenfeld R; Novick A; Vilkomerson D; Ferrara-Ryan M; Parsonnet V J Vasc Surg; 1993 Jan; 17(1):23-30; discussion 30-1. PubMed ID: 8421339 [TBL] [Abstract][Full Text] [Related]
17. A case of iliac artery injury treated by covered stent during carotid artery stenting. Hayashi K; Horie N; Sakamoto I; Morikawa M; Nagata I Acta Neurochir (Wien); 2014 Mar; 156(3):561-4. PubMed ID: 24366482 [TBL] [Abstract][Full Text] [Related]
18. Retrograde recanalization technique for use after failed antegrade angioplasty in chronic femoral artery occlusions. Schmidt A; Bausback Y; Piorkowski M; Werner M; Bräunlich S; Ulrich M; Varcoe R; Friedenberger J; Schuster J; Botsios S; Scheinert D J Endovasc Ther; 2012 Feb; 19(1):23-9. PubMed ID: 22313197 [TBL] [Abstract][Full Text] [Related]
19. Broken guidewire fragment in the radio-brachial artery during transradial sheath placement: percutaneous retrieval via femoral approach. Kim JY; Yoon J; Jung HS; Kim WJ; Yoo BS; Lee SH; Choi KH Yonsei Med J; 2005 Feb; 46(1):166-8. PubMed ID: 15744822 [TBL] [Abstract][Full Text] [Related]
20. The design and clinical application of a new #5 French angioplasty catheter. Wholey MH Cathet Cardiovasc Diagn; 1987; 13(5):347-51. PubMed ID: 2959370 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]