  • 1. Venous air embolism retrieval catheters cannot capture bubbles; an air lock is required.
    Gould DS; Gould DB
    Acta Anaesthesiol Scand; 1996 Feb; 40(2):272-4. PubMed ID: 8848930
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro comparison of central venous catheters for aspiration of venous air embolism: effect of catheter type, catheter tip position, and cardiac inclination.
    Hanna PG; Gravenstein N; Pashayan AG
    J Clin Anesth; 1991; 3(4):290-4. PubMed ID: 1910796
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Positioning the air aspiration pulmonary artery catheter introducer sheath by intravascular electrocardiography.
    Bowdle TA; Artru AA
    Anesthesiology; 1988 Aug; 69(2):276-9. PubMed ID: 3407978
    [No Abstract]   [Full Text] [Related]  

  • 4. Evaluation of a double-lumen multiorifice catheter for resuscitation of swine from lethal venous air embolism.
    Mongan PD; Hinman JA
    Anesthesiology; 1995 Nov; 83(5):1104-11. PubMed ID: 7486162
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Positioning the right atrial catheter: a model for reappraisal.
    Bunegin L; Albin MS; Helsel PE; Hoffman A; Hung TK
    Anesthesiology; 1981 Oct; 55(4):343-8. PubMed ID: 7294368
    [TBL] [Abstract][Full Text] [Related]  

  • 6. We don't treat air embolism in plastic models.
    Noel TA
    J Clin Anesth; 1992; 4(4):348-9. PubMed ID: 1419024
    [No Abstract]   [Full Text] [Related]  

  • 7. Bunegin-Albin catheter improves air retrieval and resuscitation from lethal venous air embolism in dogs.
    Colley PS; Artru AA
    Anesth Analg; 1987 Oct; 66(10):991-4. PubMed ID: 3631598
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Air embolism caused by balloon rupture resolved by manual thrombectomy catheter aspiration.
    Rigatelli G; Dell'Avvocata F; Giordan M; Cardaioli P
    Cardiovasc Revasc Med; 2011; 12(2):129-30. PubMed ID: 21421192
    [No Abstract]   [Full Text] [Related]  

  • 9. Bunegin-Albin catheter improves air retrieval and resuscitation from lethal venous air embolism in upright dogs.
    Colley PS; Artru AA
    Anesth Analg; 1989 Mar; 68(3):298-301. PubMed ID: 2919770
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Treatment of air embolism with a special pulmonary artery catheter introducer sheath in sitting dogs.
    Bowdle TA; Artru AA
    Anesthesiology; 1988 Jan; 68(1):107-10. PubMed ID: 3337360
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A new catheter for detection and treatment of venous air embolism. Technical note.
    Hicks HC; Hummel JC
    J Neurosurg; 1980 Apr; 52(4):595-8. PubMed ID: 7373385
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pressure monitoring can accurately position catheters for air embolism aspiration.
    Mongan P; Peterson RE; Culling RD
    J Clin Monit; 1992 Apr; 8(2):121-5. PubMed ID: 1583547
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical considerations concerning detection of venous air embolism.
    Albin MS; Carroll RG; Maroon JC
    Neurosurgery; 1978; 3(3):380-4. PubMed ID: 740137
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Air embolism during neurosurgery. An evaluation of right-atrial catheters for diagnosis and treatment.
    Michenfelder JD; Martin JT; Altenburg BM; Rehder K
    JAMA; 1969 May; 208(8):1353-8. PubMed ID: 5818793
    [No Abstract]   [Full Text] [Related]  

  • 15. Intracardiac aspiration for life-threatening air embolism during cardiac catheterization in tetralogy of Fallot: an aborted sudden death.
    Garg N; Moorthy N; Goel PK
    J Invasive Cardiol; 2012 Nov; 24(11):E294-6. PubMed ID: 23117324
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Placement of a multiorificed catheter in the inferior portion of the right atrium; percentage of gas retrieved and success rate of resuscitation after venous air embolism in prone dogs positioned with the abdomen hanging freely.
    Artru AA
    Anesth Analg; 1994 Oct; 79(4):740-4. PubMed ID: 7943785
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cardiac air transit following venous air embolism and right ventricular air aspiration.
    Schäfer ST; Lindemann J; Neumann A; Brendt P; Kaiser GM; Peters J
    Anaesthesia; 2009 Jul; 64(7):754-61. PubMed ID: 19624631
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intracardiac transvenous echocardiography is superior to both precordial Doppler and transesophageal echocardiography techniques for detecting venous air embolism and catheter-guided air aspiration.
    Schäfer ST; Lindemann J; Brendt P; Kaiser G; Peters J
    Anesth Analg; 2008 Jan; 106(1):45-54, table of contents. PubMed ID: 18165549
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Modification of a new catheter for air retrieval and resuscitation from lethal venous air embolism: effect of nitrous oxide on air retrieval.
    Artru AA
    Anesth Analg; 1992 Aug; 75(2):226-31. PubMed ID: 1632537
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of catheter placement in the treatment of venous air embolism.
    Sink JD; Comer PB; James PM; Loveland SR
    Ann Surg; 1976 Jan; 183(1):58-61. PubMed ID: 1247302
    [TBL] [Abstract][Full Text] [Related]  