These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 8849087)

  • 21. Occupational exposure during nitric oxide inhalational therapy in a pediatric intensive care setting.
    Markhorst DG; Leenhoven T; Uiterwijk JW; Meulenbelt J; van Vught AJ
    Intensive Care Med; 1996 Sep; 22(9):954-8. PubMed ID: 8905432
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Technical considerations for inhaled nitric oxide therapy: time response to nitric oxide dosing changes and formation of nitrogen dioxide.
    Breuer J; Waidelich F; Irtel von Brenndorff C; Sieverding L; Rosendahl W; Baden W; Gass M; Apitz J
    Eur J Pediatr; 1997 Jun; 156(6):460-2. PubMed ID: 9208243
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [New potentials for monitoring the temperature and the relative and absolute humidity of the air-oxygen mixture during the prolonged artificial ventilation of newborn infants].
    Milenin OB; Efimov MS
    Anesteziol Reanimatol; 1998; (1):49-52. PubMed ID: 9553263
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Effects of temperature and humidity on the stability of nitric oxide, and efficacy of soda lime as a selective absorber of nitrogen dioxide].
    Aida A; Miyamoto K; Saito S; Nakano T; Nishimura M; Kawakami Y; Omori Y; Ando S; Ichida T; Ishibe Y
    Nihon Kyobu Shikkan Gakkai Zasshi; 1995 Mar; 33(3):306-11. PubMed ID: 7739173
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of a new system for ventilatory administration of nitric oxide.
    Stenqvist O; Kjelltoft B; Lundin S
    Acta Anaesthesiol Scand; 1993 Oct; 37(7):687-91. PubMed ID: 8249559
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of electrochemical nitric oxide and nitrogen dioxide analyzers suitable for use during mechanical ventilation.
    Purtz EP; Hess D; Kacmarek RM
    J Clin Monit; 1997 Jan; 13(1):25-34. PubMed ID: 9058250
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effects of long-term exposure to traffic-related air pollution on respiratory and cardiovascular mortality in the Netherlands: the NLCS-AIR study.
    Brunekreef B; Beelen R; Hoek G; Schouten L; Bausch-Goldbohm S; Fischer P; Armstrong B; Hughes E; Jerrett M; van den Brandt P
    Res Rep Health Eff Inst; 2009 Mar; (139):5-71; discussion 73-89. PubMed ID: 19554969
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An evaluation of a new analyser for inhaled nitric oxide administration.
    Carter B; Holt M; Tibballs J; Hochmann M; Osborne A
    Anaesth Intensive Care; 1998 Feb; 26(1):67-9. PubMed ID: 9513671
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Flow-proportional administration of nitric oxide with a new delivery system: inspiratory nitric oxide concentration fluctuation during different flow conditions.
    Sydow M; Bristow F; Zinserling J; Allen SJ
    Chest; 1997 Aug; 112(2):496-504. PubMed ID: 9266890
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Inhaled nitric oxide reverses hypoxic pulmonary vasoconstriction in dogs. A practical nitric oxide delivery and monitoring system.
    Channick RN; Newhart JW; Johnson FW; Moser KM
    Chest; 1994 Jun; 105(6):1842-7. PubMed ID: 8205886
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Nitric oxide delivery to the lung: a model.
    Jones PR; Hooper RH; Stopp N; Moore NA
    Eur J Anaesthesiol; 2000 Mar; 17(3):160-7. PubMed ID: 10758464
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Guidelines for the safe administration of inhaled nitric oxide.
    Miller OI; Celermajer DS; Deanfield JE; Macrae DJ
    Arch Dis Child Fetal Neonatal Ed; 1994 Jan; 70(1):F47-9. PubMed ID: 8117128
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Safety aspects of delivery and monitoring of nitric oxide during mechanical ventilation.
    Westfelt UN; Lundin S; Stenqvist O
    Acta Anaesthesiol Scand; 1996 Mar; 40(3):302-10. PubMed ID: 8721460
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Morphometric analysis of alveolar responses of F344 rats to subchronic inhalation of nitric oxide.
    Mercer RR
    Res Rep Health Eff Inst; 1999 Sep; (88):1-15; discussion 17-9. PubMed ID: 10553264
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Development of nitric oxide generators to produce high-dose nitric oxide for inhalation therapy.
    Yu B; Wanderley HV; Gianni S; Carroll RW; Ichinose F; Zapol WM; Berra L
    Nitric Oxide; 2023 Sep; 138-139():17-25. PubMed ID: 37277062
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Laboratory and field validation of a combined NO2-SO2 Radiello passive sampler.
    Swaans W; Goelen E; De Fré R; Damen E; Van Avermaet P; Roekens E; Keppens V
    J Environ Monit; 2007 Nov; 9(11):1231-40. PubMed ID: 17968450
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Accuracy of measuring nitric oxide by the chemiluminescence: effect of measuring chamber pressure].
    Sasaki N; Tanifuji Y; Miyasaka K
    Masui; 1998 Aug; 47(8):1007-11. PubMed ID: 9753971
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Characteristics of several humidifiers for CPAP-therapy, invasive and non-invasive ventilation and oxygen therapy under standardised climatic conditions in a climatic chamber].
    Wenzel M; Wenzel G; Klauke M; Kerl J; Hund-Rinke K
    Pneumologie; 2008 Jun; 62(6):324-9. PubMed ID: 18535976
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of nitric oxide predilution on inhaled nitrogen dioxide concentrations.
    Foubert L; Mareels K; den Blauwen N; Herregods L; Rolly G
    Anaesthesia; 1999 Mar; 54(3):220-5. PubMed ID: 10364856
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Validation of a simple method assessing nitric oxide and nitrogen dioxide concentrations.
    Moutafis M; Hatahet Z; Castelain MH; Renaudin MH; Monnot A; Fischler M
    Intensive Care Med; 1995 Jun; 21(6):537-41. PubMed ID: 7560498
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.