These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

303 related articles for article (PubMed ID: 8850457)

  • 1. Characterization of noble metal implant cylinders: as-received cylinders and cast interfaces with noble metal alloys.
    Carr AB; Brantley WA
    J Prosthet Dent; 1996 Jan; 75(1):77-85. PubMed ID: 8850457
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Titanium alloy cylinders in implant framework fabrication: a study of the cylinder-alloy interface.
    Carr AB; Brantley WA
    J Prosthet Dent; 1993 Apr; 69(4):391-7. PubMed ID: 8463969
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Analysis of four dental alloys following torch/centrifugal and induction/ vacuum-pressure casting procedures.
    Thompson GA; Luo Q; Hefti A
    J Prosthet Dent; 2013 Dec; 110(6):471-80. PubMed ID: 24120072
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microstructure, elemental composition, hardness and crystal structure study of the interface between a noble implant component and cast noble alloys.
    Ucar Y; Brantley WA; Johnston WM; Iijima M; Han DS; Dasgupta T
    J Prosthet Dent; 2011 Sep; 106(3):170-8. PubMed ID: 21889003
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Characterization of the interface between cast-to Co-Cr implant cylinders and cast Co-Cr alloys.
    Ozkomur A; Ucar Y; Ekren O; Arai Shinkai RS; Teixeira ER
    J Prosthet Dent; 2016 May; 115(5):592-600. PubMed ID: 26794696
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Characterization of the interface between prefabricated gold copings and cast dental alloy in implant restorations.
    Carotenuto G; Palumbo M; Zarone F; Nicolais L
    Clin Oral Implants Res; 1999 Apr; 10(2):131-8. PubMed ID: 10219132
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterization of cast-to implant components from five manufacturers.
    Ucar Y; Brantley WA; Bhattiprolu SN; Johnston WM; McGlumphy EA
    J Prosthet Dent; 2009 Oct; 102(4):216-23. PubMed ID: 19782823
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of fabrication, finishing, and polishing procedures on preload in prostheses using conventional "gold' and plastic cylinders.
    Carr AB; Brunski JB; Hurley E
    Int J Oral Maxillofac Implants; 1996; 11(5):589-98. PubMed ID: 8908856
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Surface and elemental alterations of dental alloys induced by electro discharge machining (EDM).
    Zinelis S
    Dent Mater; 2007 May; 23(5):601-7. PubMed ID: 16846638
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro vertical misfit evaluation of cast frameworks for cement-retained implant-supported partial prostheses.
    Oyagüe RC; Turrión AS; Toledano M; Monticelli F; Osorio R
    J Dent; 2009 Jan; 37(1):52-8. PubMed ID: 18951675
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The influence of alloy composition and casting procedure upon the corrosion behaviour of dental alloys: an in vitro study.
    Mülders C; Darwish M; Holze R
    J Oral Rehabil; 1996 Dec; 23(12):825-31. PubMed ID: 8971644
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of soldering methods on tensile strength of a gold-palladium metal ceramic alloy.
    Ghadhanfari HA; Khajah HM; Monaco EA; Kim H
    J Prosthet Dent; 2014 Oct; 112(4):994-1000. PubMed ID: 24840906
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Corrosion behavior of as-received and previously cast type III gold alloy.
    Ayad MF; Ayad GM
    J Prosthodont; 2010 Apr; 19(3):194-9. PubMed ID: 20210863
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanical properties, fracture surface characterization, and microstructural analysis of six noble dental casting alloys.
    Ucar Y; Brantley WA; Johnston WM; Dasgupta T
    J Prosthet Dent; 2011 Jun; 105(6):394-402. PubMed ID: 21640241
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fabrication of titanium removable dental prosthesis frameworks with a 2-step investment coating method.
    Koike M; Hummel SK; Ball JD; Okabe T
    J Prosthet Dent; 2012 Jun; 107(6):393-9. PubMed ID: 22633596
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effect of primers on shear bond strength of acrylic resins to different types of metals.
    Bulbul M; Kesim B
    J Prosthet Dent; 2010 May; 103(5):303-8. PubMed ID: 20416414
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Basic evaluation of cast joining for electroformed coping using multi-purpose alloys.
    Yamaguchi Y; Takahashi H; Shiota M; Iwasaki N
    Dent Mater J; 2005 Sep; 24(3):356-61. PubMed ID: 16281324
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Segregation in precious-metal dental-casting alloys.
    Drápal S; Pomajbík J
    J Dent Res; 1993 Mar; 72(3):587-91. PubMed ID: 8450118
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of two opaquing techniques and two metal surface conditions on metal-ceramic bond strength.
    Rake PC; Goodacre CJ; Moore BK; Munoz CA
    J Prosthet Dent; 1995 Jul; 74(1):8-17. PubMed ID: 7674194
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanical properties and microstructures of cast Ti-Cu alloys.
    Kikuchi M; Takada Y; Kiyosue S; Yoda M; Woldu M; Cai Z; Okuno O; Okabe T
    Dent Mater; 2003 May; 19(3):174-81. PubMed ID: 12628428
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.