152 related articles for article (PubMed ID: 8857483)
1. Estimation of pulmonary artery pressure by spectral analysis of the second heart sound.
Chen D; Pibarot P; Honos G; Durand LG
Am J Cardiol; 1996 Oct; 78(7):785-9. PubMed ID: 8857483
[TBL] [Abstract][Full Text] [Related]
2. Automatic measure of the split in the second cardiac sound by using the wavelet transform technique.
Debbal SM; Bereksi-Reguig F
Comput Biol Med; 2007 Mar; 37(3):269-76. PubMed ID: 16574092
[TBL] [Abstract][Full Text] [Related]
3. A new noninvasive method for estimation of pulmonary arterial pressure in mitral stenosis.
Longhini C; Baracca E; Brunazzi C; Vaccari M; Longhini L; Barbaresi F
Am J Cardiol; 1991 Aug; 68(4):398-401. PubMed ID: 1858684
[No Abstract] [Full Text] [Related]
4. Analysis of the second heart sound using continuous wavelet transform.
Debbal SM; Bereksi-Reguig F
J Med Eng Technol; 2004; 28(4):151-6. PubMed ID: 15371005
[TBL] [Abstract][Full Text] [Related]
5. A dynamic method to estimate the time split between the A2 and P2 components of the S2 heart sound.
Nigam V; Priemer R
Physiol Meas; 2006 Jul; 27(7):553-67. PubMed ID: 16705255
[TBL] [Abstract][Full Text] [Related]
6. Extraction of the aortic and pulmonary components of the second heart sound using a nonlinear transient chirp signal model.
Xu J; Durand LG; Pibarot P
IEEE Trans Biomed Eng; 2001 Mar; 48(3):277-83. PubMed ID: 11327495
[TBL] [Abstract][Full Text] [Related]
7. Usefulness of the second heart sound for predicting pulmonary hypertension in patients with interstitial lung disease.
Cobra Sde B; Cardoso RM; Rodrigues MP
Sao Paulo Med J; 2016; 134(1):34-9. PubMed ID: 26786609
[TBL] [Abstract][Full Text] [Related]
8. Spectral analysis of the first heart sound in patients with biological mitral valve prosthesis. Preliminary results.
Longhini C; Baracca E; Aggio S; Brunazzi C; Gallucci V; Pansini R
Acta Cardiol; 1990; 45(3):231-6. PubMed ID: 2368544
[No Abstract] [Full Text] [Related]
9. Smart phone monitoring of second heart sound split.
Thiyagaraja SR; Vempati J; Dantu R; Sarma T; Dantu S
Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():2181-4. PubMed ID: 25570418
[TBL] [Abstract][Full Text] [Related]
10. Bias and variability of diagnostic spectral parameters extracted from closing sounds produced by bioprosthetic valves implanted in the mitral position.
Cloutier G; Durand LG; Guardo R; Sabbah HN; Stein PD
IEEE Trans Biomed Eng; 1989 Aug; 36(8):815-26. PubMed ID: 2759640
[TBL] [Abstract][Full Text] [Related]
11. Comparison of spectral techniques for computer-assisted classification of spectra of heart sounds in patients with porcine bioprosthetic valves.
Durand LG; Guo Z; Sabbah HN; Stein PD
Med Biol Eng Comput; 1993 May; 31(3):229-36. PubMed ID: 8412375
[TBL] [Abstract][Full Text] [Related]
12. Analysis and study of the variation of splitting in the second heartbeat sound of wavelet transform.
Debbal SM; Bereksi-Reguig F
J Med Eng Technol; 2006; 30(5):298-305. PubMed ID: 16980284
[TBL] [Abstract][Full Text] [Related]
13. Automatic detection of sounds and murmurs in patients with Ionescu-Shiley aortic bioprostheses.
Baranek HL; Lee HC; Cloutier G; Durand LG
Med Biol Eng Comput; 1989 Sep; 27(5):449-55. PubMed ID: 2622226
[TBL] [Abstract][Full Text] [Related]
14. Spectral analysis of closing sounds produced by Ionescu-Shiley bioprosthetic aortic heart valves. Part 2. Computer simulation of aortic closing sounds and estimation of their truncation level and signal-to-noise ratio.
Cloutier G; Grenier MC; Guardo R; Durand LG
Med Biol Eng Comput; 1987 Sep; 25(5):492-6. PubMed ID: 3446970
[No Abstract] [Full Text] [Related]
15. Automatic timing of aortic valve closure in apical tissue Doppler images.
Aase SA; Stoylen A; Ingul CB; Frigstad S; Torp H
Ultrasound Med Biol; 2006 Jan; 32(1):19-27. PubMed ID: 16364793
[TBL] [Abstract][Full Text] [Related]
16. Impact of valve prosthesis-patient mismatch on pulmonary arterial pressure after mitral valve replacement.
Li M; Dumesnil JG; Mathieu P; Pibarot P
J Am Coll Cardiol; 2005 Apr; 45(7):1034-40. PubMed ID: 15808760
[TBL] [Abstract][Full Text] [Related]
17. Frequency spectra of the first heart sound and of the aortic component of the second heart sound in patients with degenerated porcine bioprosthetic valves.
Stein PD; Sabbah HN; Lakier JB; Kemp SR; Magilligan DJ
Am J Cardiol; 1984 Feb; 53(4):557-61. PubMed ID: 6695784
[TBL] [Abstract][Full Text] [Related]
18. Artificial neural networks in computer-assisted classification of heart sounds in patients with porcine bioprosthetic valves.
Guo Z; Durand LG; Lee HC; Allard L; Grenier MC; Stein PD
Med Biol Eng Comput; 1994 May; 32(3):311-6. PubMed ID: 7934256
[TBL] [Abstract][Full Text] [Related]
19. Time-frequency and time-scale techniques for the classification of native and bioprosthetic heart valve sounds.
Bentley PM; Grant PM; McDonnell JT
IEEE Trans Biomed Eng; 1998 Jan; 45(1):125-8. PubMed ID: 9444847
[TBL] [Abstract][Full Text] [Related]
20. Phonocardiogram signal analysis: techniques and performance comparison.
Obaidat MS
J Med Eng Technol; 1993; 17(6):221-7. PubMed ID: 8169938
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]