These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 8858646)

  • 21. End tidal carbon dioxide monitoring in spontaneously breathing, nonintubated patients. A clinical comparison between conventional sidestream and microstream capnometers.
    Casati A; Gallioli G; Passaretta R; Scandroglio M; Bignami E; Torri G
    Minerva Anestesiol; 2001 Apr; 67(4):161-4. PubMed ID: 11376503
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Capnography as a predictor of the return of spontaneous circulation.
    Hatlestad D
    Emerg Med Serv; 2004 Aug; 33(8):75-80; quiz 115. PubMed ID: 15368978
    [TBL] [Abstract][Full Text] [Related]  

  • 23. An Update on End-Tidal CO2 Monitoring.
    Selby ST; Abramo T; Hobart-Porter N
    Pediatr Emerg Care; 2018 Dec; 34(12):888-892. PubMed ID: 30507754
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A comparison of the end-tidal CO2 measured by portable capnometer and the arterial PCO2 in spontaneously breathing patients.
    Takano Y; Sakamoto O; Kiyofuji C; Ito K
    Respir Med; 2003 May; 97(5):476-81. PubMed ID: 12735663
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Capnography during sedation/analgesia in the pediatric emergency department.
    McQuillen KK; Steele DW
    Pediatr Emerg Care; 2000 Dec; 16(6):401-4. PubMed ID: 11138881
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Detection of carbon dioxide thresholds using low-flow sidestream capnography in ventilated preterm infants.
    Lopez E; Grabar S; Barbier A; Krauss B; Jarreau PH; Moriette G
    Intensive Care Med; 2009 Nov; 35(11):1942-9. PubMed ID: 19760396
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Cerebral oximetry with blood volume index and capnography in intubated and hyperventilated patients.
    Bagwell TA; Abramo TJ; Albert GW; Orsborn JW; Storm EA; Hobart-Porter NW; Thompson TM; Ocal E; Hu Z; Nick T
    Am J Emerg Med; 2016 Jun; 34(6):1102-7. PubMed ID: 27146456
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Assessment of sidestream end-tidal capnography in ventilated infants on the neonatal unit.
    Williams E; Dassios T; Greenough A
    Pediatr Pulmonol; 2020 Jun; 55(6):1468-1473. PubMed ID: 32187888
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A comparison of the end-tidal-CO2 documented by capnometry and the arterial pCO2 in emergency patients.
    Prause G; Hetz H; Lauda P; Pojer H; Smolle-Juettner F; Smolle J
    Resuscitation; 1997 Oct; 35(2):145-8. PubMed ID: 9316198
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Prognostication of out-of-hospital cardiac arrest patients by 3-min end-tidal capnometry level in emergency department.
    Poon KM; Lui CT; Tsui KL
    Resuscitation; 2016 May; 102():80-4. PubMed ID: 26948821
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Is measurement of end-tidal CO2 through a nasal cannula reliable?
    Fukuda K; Ichinohe T; Kaneko Y
    Anesth Prog; 1997; 44(1):23-6. PubMed ID: 9481977
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Exhaled end-tidal carbon dioxide as a predictor of lactate and pediatric sepsis.
    Cully M; Treut M; Thompson AD; DePiero AD
    Am J Emerg Med; 2020 Dec; 38(12):2620-2624. PubMed ID: 33046322
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Mainstream capnography system for nonintubated children in the postanesthesia care unit: Performance with changing flow rates, and a comparison to side stream capnography.
    Nagoshi M; Morzov R; Hotz J; Belson P; Matar M; Ross P; Wetzel R
    Paediatr Anaesth; 2016 Dec; 26(12):1179-1187. PubMed ID: 27663694
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Does end-tidal carbon dioxide monitoring detect respiratory events prior to current sedation monitoring practices?
    Burton JH; Harrah JD; Germann CA; Dillon DC
    Acad Emerg Med; 2006 May; 13(5):500-4. PubMed ID: 16569750
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Agreement Between Arterial Carbon Dioxide Levels With End-Tidal Carbon Dioxide Levels and Associated Factors in Children Hospitalized With Traumatic Brain Injury.
    Yang JT; Erickson SL; Killien EY; Mills B; Lele AV; Vavilala MS
    JAMA Netw Open; 2019 Aug; 2(8):e199448. PubMed ID: 31418806
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Utility of initial prehospital end-tidal carbon dioxide measurements to predict poor outcomes in adult asthmatic patients.
    Nagurka R; Bechmann S; Gluckman W; Scott SR; Compton S; Lamba S
    Prehosp Emerg Care; 2014; 18(2):180-4. PubMed ID: 24400881
    [TBL] [Abstract][Full Text] [Related]  

  • 37. End tidal carbon dioxide is as reliable as transcutaneous monitoring in ventilated postsurgical neonates.
    Tingay DG; Mun KS; Perkins EJ
    Arch Dis Child Fetal Neonatal Ed; 2013 Mar; 98(2):F161-4. PubMed ID: 22887048
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Accuracy of postoperative end-tidal Pco2 measurements with mainstream and sidestream capnography in non-obese patients and in obese patients with and without obstructive sleep apnea.
    Kasuya Y; Akça O; Sessler DI; Ozaki M; Komatsu R
    Anesthesiology; 2009 Sep; 111(3):609-15. PubMed ID: 19672177
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Correlation of Nasal Cannula End-Tidal Carbon Dioxide Concentration With Need for Critical Resources for Blunt Trauma Patients Triaged to Lower-Tier Trauma Activation.
    Day DL; Terada KEF; Vondrus P; Watabayashi R; Severino R; Inn H; Ng K
    J Trauma Nurs; 2020; 27(2):88-95. PubMed ID: 32132488
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A pharmacodynamic model of respiratory rate and end-tidal carbon dioxide values during anesthesia in children.
    Lee JH; Kang PY; Jang YE; Kim EH; Kim JT; Kim HS
    Acta Pharmacol Sin; 2019 May; 40(5):642-647. PubMed ID: 30166623
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.