These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

195 related articles for article (PubMed ID: 8866068)

  • 41. Complication rate in mandibular angle fractures-one vs. two plates: a 12-year retrospective analysis.
    Ferrari R; Lanzer M; Wiedemeier D; Rücker M; Bredell M
    Oral Maxillofac Surg; 2018 Dec; 22(4):435-441. PubMed ID: 30327980
    [TBL] [Abstract][Full Text] [Related]  

  • 42. [AO and miniplate osteosynthesis of the mandible in an 8-year comparison].
    Niederhagen B; Anke S; Hültenschmidt D; Appel T
    Fortschr Kiefer Gesichtschir; 1996; 41():58-60. PubMed ID: 8755400
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Open reduction and internal fixation of combined angle and body/symphysis fractures of the mandible: how much fixation is enough?
    Ellis E
    J Oral Maxillofac Surg; 2013 Apr; 71(4):726-33. PubMed ID: 23245520
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Is lag screw fixation superior to plate fixation to treat fractures of the mandibular symphysis?
    Ellis E
    J Oral Maxillofac Surg; 2012 Apr; 70(4):875-82. PubMed ID: 22209100
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Prospective randomized clinical trial comparing bite force in 2-mm locking plates versus 2-mm standard plates in treatment of mandibular fractures.
    Agarwal M; Mohammad S; Singh RK; Singh V
    J Oral Maxillofac Surg; 2011 Jul; 69(7):1995-2000. PubMed ID: 21272972
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Fixed angle plate fixation of comminuted patellar fractures.
    Moore TB; Sampathi BR; Zamorano DP; Tynan MC; Scolaro JA
    Injury; 2018 Jun; 49(6):1203-1207. PubMed ID: 29609972
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Titanium Mesh Shaping and Fixation for the Treatment of Comminuted Mandibular Fractures.
    Dai J; Shen G; Yuan H; Zhang W; Shen S; Shi J
    J Oral Maxillofac Surg; 2016 Feb; 74(2):337.e1-337.e11. PubMed ID: 26529196
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Incidence, aetiology, treatment outcome and complications of maxillofacial fractures. A retrospective study from Northern Greece.
    Kyrgidis A; Koloutsos G; Kommata A; Lazarides N; Antoniades K
    J Craniomaxillofac Surg; 2013 Oct; 41(7):637-43. PubMed ID: 23332470
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Intraosseous wire fixation versus rigid osseous fixation of mandibular fractures: a preliminary report.
    Theriot BA; Van Sickels JE; Triplett RG; Nishioka GJ
    J Oral Maxillofac Surg; 1987 Jul; 45(7):577-82. PubMed ID: 3474374
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Rigid internal fixation for the treatment of infected mandibular fractures.
    Koury M; Ellis E
    J Oral Maxillofac Surg; 1992 May; 50(5):434-43; discussion 443-4. PubMed ID: 1573478
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Treatment modalities for mandibular angle fractures.
    Gear AJ; Apasova E; Schmitz JP; Schubert W
    J Oral Maxillofac Surg; 2005 May; 63(5):655-63. PubMed ID: 15883941
    [TBL] [Abstract][Full Text] [Related]  

  • 52. [2.7 mm (AO) or 2.0 mm miniplate osteosynthesis in mandibular fractures].
    Schmelzeisen R; Schliephake H; Schultze-Mosgau S; Krause A
    Fortschr Kiefer Gesichtschir; 1996; 41():88-90. PubMed ID: 8755409
    [TBL] [Abstract][Full Text] [Related]  

  • 53. The retromandibular transparotid approach for reduction and rigid internal fixation using two locking miniplates in mandibular condylar neck fractures.
    Kanno T; Sukegawa S; Tatsumi H; Nariai Y; Ishibashi H; Furuki Y; Sekine J
    Int J Oral Maxillofac Surg; 2014 Feb; 43(2):177-84. PubMed ID: 24070772
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Clinical implementation of a multidirectional, angular stable osteosynthesis system in maxillofacial traumatology.
    Gbara A; Heiland M; Schmelzle R; Blake F
    J Craniomaxillofac Surg; 2008 Apr; 36(3):157-160. PubMed ID: 18321723
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Fixation of mandibular angle fractures with a 2.0-mm 3-dimensional curved angle strut plate.
    Guimond C; Johnson JV; Marchena JM
    J Oral Maxillofac Surg; 2005 Feb; 63(2):209-14. PubMed ID: 15690289
    [TBL] [Abstract][Full Text] [Related]  

  • 56. An audit of mandibular fractures treated by intermaxillary fixation, intraosseous wiring and compression plating.
    Zachariades N; Mezitis M; Rallis G
    Br J Oral Maxillofac Surg; 1996 Aug; 34(4):293-7. PubMed ID: 8866063
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Intraoral monocortical miniplating of mandible fractures.
    Valentino J; Levy FE; Marentette LJ
    Arch Otolaryngol Head Neck Surg; 1994 Jun; 120(6):605-12. PubMed ID: 8198783
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Use of straight and curved 3-dimensional titanium miniplates for fracture fixation at the mandibular angle.
    Zix J; Lieger O; Iizuka T
    J Oral Maxillofac Surg; 2007 Sep; 65(9):1758-63. PubMed ID: 17719394
    [TBL] [Abstract][Full Text] [Related]  

  • 59. A prospective randomized clinical trial comparing 2.0-mm locking plates to 2.0-mm standard plates in treatment of mandible fractures.
    Collins CP; Pirinjian-Leonard G; Tolas A; Alcalde R
    J Oral Maxillofac Surg; 2004 Nov; 62(11):1392-5. PubMed ID: 15510361
    [TBL] [Abstract][Full Text] [Related]  

  • 60. A retrospective analysis of 279 patients with isolated mandibular fractures treated with titanium miniplates.
    Tuovinen V; Nørholt SE; Sindet-Pedersen S; Jensen J
    J Oral Maxillofac Surg; 1994 Sep; 52(9):931-5; discussion 935-6. PubMed ID: 8064456
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.