These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
111 related articles for article (PubMed ID: 8867449)
1. Monitoring NMR spectrometer performance during data accumulation for macromolecular structure determination. Braun D; Wider G; Wüthrich K J Magn Reson B; 1996 Mar; 110(3):313-5. PubMed ID: 8867449 [No Abstract] [Full Text] [Related]
2. Signal-to-noise and magnetic susceptibility trade-offs in solenoidal microcoils for NMR. Webb AG; Grant SC J Magn Reson B; 1996 Oct; 113(1):83-7. PubMed ID: 8888593 [No Abstract] [Full Text] [Related]
3. Water modeled signal removal and data quantification in localized MR spectroscopy using a time-scale postacquistion method. Serrai H; Senhadji L; Clayton DB; Zuo C; Lenkinski RE J Magn Reson; 2001 Mar; 149(1):45-51. PubMed ID: 11273750 [TBL] [Abstract][Full Text] [Related]
5. Single-shot spectroscopic imaging (SISSI) using a PEEP/BURST hybrid. Jakob PM; Kober F; Pohmann R; Haase A J Magn Reson B; 1996 Mar; 110(3):278-83. PubMed ID: 8867443 [No Abstract] [Full Text] [Related]
6. Effects of instrumental artifacts on triple quantum filtered NMR spectra for spin I=3/2. Sun C; Wang X; Wang Z J Magn Reson; 2016 Jul; 268():10-17. PubMed ID: 27149654 [TBL] [Abstract][Full Text] [Related]
7. Application of genetic algorithms to spectral quantification. Metzger GJ; Patel M; Hu X J Magn Reson B; 1996 Mar; 110(3):316-20. PubMed ID: 8867450 [No Abstract] [Full Text] [Related]
8. Multiple-pi-pulse sequences in biological solid-state NMR. Enhancement of sensitivity by permutation of the phases. Li Y; Evans JN J Magn Reson B; 1996 Jun; 111(3):296-9. PubMed ID: 8661296 [No Abstract] [Full Text] [Related]
9. Total compensation of pulse transients inside a resonator. Tabuchi Y; Negoro M; Takeda K; Kitagawa M J Magn Reson; 2010 Jun; 204(2):327-32. PubMed ID: 20378380 [TBL] [Abstract][Full Text] [Related]
12. Determination of backbone torsion angle epsilon of DNA duplexes in solution from 3JC4'P and 3JH3'P, using heteronuclear single-quantum-coherence spectroscopy. Lam SL; Au-Yeung SC J Magn Reson B; 1996 Oct; 113(1):59-64. PubMed ID: 8888591 [No Abstract] [Full Text] [Related]
13. Compensation for unknown acquisition delay caused by digital receiver without external synchronization in NMR and MRI. Qin X; Jie S; Jianqi L; Gengying L MAGMA; 2005 Sep; 18(4):217-24. PubMed ID: 16155760 [TBL] [Abstract][Full Text] [Related]
14. Tracer diffusion measurements in solid lithium: a test case for the comparison between NMR in static and pulsed magnetic field gradients after upgrading a standard solid state NMR spectrometer. Marion Fischer D; Duwe P; Indris S; Heitjans P Solid State Nucl Magn Reson; 2004 Sep; 26(2):74-83. PubMed ID: 15276637 [TBL] [Abstract][Full Text] [Related]
15. Phosphorus J-scaled band-selective homonuclear-decoupled TOCSY for H3'-31P coupling-constant measurement in DNA oligomers. Krishnamurthy VV J Magn Reson B; 1996 Oct; 113(1):46-52. PubMed ID: 8888590 [No Abstract] [Full Text] [Related]
17. Undersampling to acquire nuclear magnetic resonance images. Pérez P; Santos A Med Eng Phys; 2004 Jul; 26(6):523-9. PubMed ID: 15234688 [TBL] [Abstract][Full Text] [Related]
18. Two-dimensional linear-combination model fitting of magnetic resonance spectra to define the macromolecule baseline using FiTAID, a Fitting Tool for Arrays of Interrelated Datasets. Chong DG; Kreis R; Bolliger CS; Boesch C; Slotboom J MAGMA; 2011 Jun; 24(3):147-64. PubMed ID: 21424575 [TBL] [Abstract][Full Text] [Related]
19. [Design of a gavanically isolated wide SCSI processor equipment interface for bidirectional data transfer with a data rate of 10 MByte/s]. Käser M; Starck W; Dössel O; Meyer-Waarden K Biomed Tech (Berl); 1998; 43 Suppl():544-5. PubMed ID: 9859483 [No Abstract] [Full Text] [Related]