These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
206 related articles for article (PubMed ID: 8870914)
21. Computer-aided recording of automatic endoscope washing and disinfection processes as an integral part of medical documentation for quality assurance purposes. Krakamp B; Kirschberg O; Scheding A; Emmerich D; Klein S; Saers T BMC Gastroenterol; 2010 Jul; 10():76. PubMed ID: 20615248 [TBL] [Abstract][Full Text] [Related]
22. Endoscope disinfection by ortho-phthalaldehyde in a clinical setting: an evaluation of reprocessing time and costs compared with glutaraldehyde. Hession SM Gastroenterol Nurs; 2003; 26(3):110-4. PubMed ID: 12811321 [TBL] [Abstract][Full Text] [Related]
23. Automated endoscope reprocessors. ; Parsi MA; Sullivan SA; Goodman A; Manfredi M; Navaneethan U; Pannala R; Smith ZL; Thosani N; Banerjee S; Maple JT Gastrointest Endosc; 2016 Dec; 84(6):885-892. PubMed ID: 27765382 [No Abstract] [Full Text] [Related]
24. Worldwide practices on flexible endoscope reprocessing. Kenters N; Tartari E; Hopman J; El-Sokkary RH; Nagao M; Marimuthu K; Vos MC; ; Huijskens EGW; Voss A Antimicrob Resist Infect Control; 2018; 7():153. PubMed ID: 30564309 [TBL] [Abstract][Full Text] [Related]
25. Evaluation of the Quality of Reprocessing of Gastrointestinal Endoscopes. Saviuc P; Picot-Guéraud R; Shum Cheong Sing J; Batailler P; Pelloux I; Brenier-Pinchart MP; Dobremez V; Mallaret MR Infect Control Hosp Epidemiol; 2015 Sep; 36(9):1017-23. PubMed ID: 26022365 [TBL] [Abstract][Full Text] [Related]
26. Contamination of the modified olympus EW-10 and EW-20 automatic flexible endoscope reprocessors. Health Devices; 1994 Apr; 23(4):143-5. PubMed ID: 8034515 [No Abstract] [Full Text] [Related]
27. Endoscope reprocessing methods: a prospective study on the impact of human factors and automation. Ofstead CL; Wetzler HP; Snyder AK; Horton RA Gastroenterol Nurs; 2010; 33(4):304-11. PubMed ID: 20679783 [TBL] [Abstract][Full Text] [Related]
28. Deficiencies of automatic endoscopic reprocessors: a method to achieve high-grade disinfection of endoscopes. Ido K; Ishino Y; Ota Y; Kihira K; Taniguchi Y; Saifuku K; Satoh K; Kawamoto C; Hayashi M; Kimura K Gastrointest Endosc; 1996 Nov; 44(5):583-6. PubMed ID: 8934166 [TBL] [Abstract][Full Text] [Related]
30. The use of rapid indicators for the detection of organic residues on clinically used gastrointestinal endoscopes with and without visually apparent debris. Visrodia KH; Ofstead CL; Yellin HL; Wetzler HP; Tosh PK; Baron TH Infect Control Hosp Epidemiol; 2014 Aug; 35(8):987-94. PubMed ID: 25026614 [TBL] [Abstract][Full Text] [Related]
34. Sterilization, high-level disinfection, and environmental cleaning. Rutala WA; Weber DJ Infect Dis Clin North Am; 2011 Mar; 25(1):45-76. PubMed ID: 21315994 [TBL] [Abstract][Full Text] [Related]
35. GI endoscopic reprocessing practices in the United States. Cheung RJ; Ortiz D; DiMarino AJ Gastrointest Endosc; 1999 Sep; 50(3):362-8. PubMed ID: 10462657 [TBL] [Abstract][Full Text] [Related]
36. Surveillance culture of endoscope to monitor the quality of high-level disinfection of gastrointestinal reprocessing. Chiu KW; Fong TV; Wu KL; Chiu YC; Chou YP; Kuo CM; Chuah SK; Kuo CH; Chiou SS; ChangChien CS Hepatogastroenterology; 2010; 57(99-100):531-4. PubMed ID: 20698222 [TBL] [Abstract][Full Text] [Related]
37. Endoscope reprocessing and repair costs. Burdick JS; Hambrick D Gastrointest Endosc Clin N Am; 2004 Oct; 14(4):717-24, ix-x. PubMed ID: 15363776 [TBL] [Abstract][Full Text] [Related]
39. Microbiologic assessment of flexible gastrointestinal endoscope reprocessing using a pump-assisted sampling technique: an investigation involving all endoscopy units in Tianjin, China. Ji XY; Ning PY; Zhang W; Yang DJ; Liu H; Liu J; Song J; Fei CN Am J Infect Control; 2018 Jul; 46(7):e43-e48. PubMed ID: 29778431 [TBL] [Abstract][Full Text] [Related]
40. Application of environmental sampling to flexible endoscope reprocessing: the importance of monitoring the rinse water. Muscarella LF Infect Control Hosp Epidemiol; 2002 May; 23(5):285-9. PubMed ID: 12026158 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]