157 related articles for article (PubMed ID: 8873039)
21. Dose distribution considerations of medium energy electron beams at extended source-to-surface distance.
Saw CB; Ayyangar KM; Pawlicki T; Korb LJ
Int J Radiat Oncol Biol Phys; 1995 Apr; 32(1):159-64. PubMed ID: 7721612
[TBL] [Abstract][Full Text] [Related]
22. Bone and mucosal dosimetry in skin radiation therapy: a Monte Carlo study using kilovoltage photon and megavoltage electron beams.
Chow JC; Jiang R
Phys Med Biol; 2012 Jun; 57(12):3885-99. PubMed ID: 22642985
[TBL] [Abstract][Full Text] [Related]
23. Water equivalence evaluation of PRESAGE(®) formulations for megavoltage electron beams: a Monte Carlo study.
Gorjiara T; Kuncic Z; Hill R; Adamovics J; Baldock C
Australas Phys Eng Sci Med; 2012 Dec; 35(4):455-63. PubMed ID: 23299985
[TBL] [Abstract][Full Text] [Related]
24. A fast and sensitive TLD method for measurement of energy and homogeneity of electron beams using transmitted radiation through lead.
Pradhan AS; Quast U; Sharma PK
Phys Med Biol; 1994 Sep; 39(9):1367-76. PubMed ID: 15552110
[TBL] [Abstract][Full Text] [Related]
25. Surface dosimetry for oblique tangential photon beams: a Monte Carlo simulation study.
Chow JC; Grigorov GN
Med Phys; 2008 Jan; 35(1):70-6. PubMed ID: 18293563
[TBL] [Abstract][Full Text] [Related]
26. The effect of a carbon-fiber couch on the depth-dose curves and transmission properties for megavoltage photon beams.
Poppe B; Chofor N; Rühmann A; Kunth W; Djouguela A; Kollhoff R; Willborn KC
Strahlenther Onkol; 2007 Jan; 183(1):43-8. PubMed ID: 17225945
[TBL] [Abstract][Full Text] [Related]
27. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).
Tedgren AC; Hedman A; Grindborg JE; Carlsson GA
Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372
[TBL] [Abstract][Full Text] [Related]
28. An evaluation of the recommendations of the TG-25 protocol for determination of depth dose curves for electron beams using ionization chambers.
Huq MS; Agostinelli AG; Nath R
Med Phys; 1995 Aug; 22(8):1333-7. PubMed ID: 7476721
[TBL] [Abstract][Full Text] [Related]
29. Measurement of superficial dose from a static tomotherapy beam.
Smith KS; Gibbons JP; Gerbi BJ; Hogstrom KR
Med Phys; 2008 Feb; 35(2):769-74. PubMed ID: 18383699
[TBL] [Abstract][Full Text] [Related]
30. An isodose shift technique for obliquely incident electron beams.
Ulin K; Sternick ES
Med Phys; 1989; 16(6):905-10. PubMed ID: 2511399
[TBL] [Abstract][Full Text] [Related]
31. A comparison of the AAPM "Protocol for the determination of absorbed dose from high-energy photon and electron beams" with currently used protocols.
Hunt MA; Malik S; Thomason C; Masterson ME
Med Phys; 1984; 11(6):806-13. PubMed ID: 6439991
[TBL] [Abstract][Full Text] [Related]
32. Determination of surface dose and the effect of bolus to surface dose in electron beams.
Günhan B; Kemikler G; Koca A
Med Dosim; 2003; 28(3):193-8. PubMed ID: 14563440
[TBL] [Abstract][Full Text] [Related]
33. Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom.
Bazalova-Carter M; Liu M; Palma B; Dunning M; McCormick D; Hemsing E; Nelson J; Jobe K; Colby E; Koong AC; Tantawi S; Dolgashev V; Maxim PG; Loo BW
Med Phys; 2015 Apr; 42(4):1606-13. PubMed ID: 25832051
[TBL] [Abstract][Full Text] [Related]
34. Convolution calculations of dose in the buildup regions for high energy photon beams obliquely incident.
Dupont S; Rosenwald JC; Beauvais H
Med Phys; 1994 Sep; 21(9):1391-400. PubMed ID: 7838049
[TBL] [Abstract][Full Text] [Related]
35. Evaluation of Al2O3:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy.
Yukihara EG; Mardirossian G; Mirzasadeghi M; Guduru S; Ahmad S
Med Phys; 2008 Jan; 35(1):260-9. PubMed ID: 18293581
[TBL] [Abstract][Full Text] [Related]
36. Dose enhancement in bone in electron beam therapy.
Prasad SC; Ames TE; Howard TB; Bassano DA; Chung CT; King GA; Sagerman RH
Radiology; 1984 May; 151(2):513-6. PubMed ID: 6424176
[TBL] [Abstract][Full Text] [Related]
37. An assessment of the characteristics of n-type diodes for use in electron beam radiotherapy.
Gibson BJ; Langmack KA
Med Dosim; 2004; 29(3):161-5. PubMed ID: 15324911
[TBL] [Abstract][Full Text] [Related]
38. Monte Carlo study of the depth-dependent fluence perturbation in parallel-plate ionization chambers in electron beams.
Zink K; Czarnecki D; Looe HK; von Voigts-Rhetz P; Harder D
Med Phys; 2014 Nov; 41(11):111707. PubMed ID: 25370621
[TBL] [Abstract][Full Text] [Related]
39. Monte Carlo calculations of electron beam quality conversion factors for several ion chamber types.
Muir BR; Rogers DW
Med Phys; 2014 Nov; 41(11):111701. PubMed ID: 25370615
[TBL] [Abstract][Full Text] [Related]
40. Angular distributions of absorbed dose of Bremsstrahlung and secondary electrons induced by 18-, 28- and 38-MeV electron beams in thick targets.
Takada M; Kosako K; Oishi K; Nakamura T; Sato K; Kamiyama T; Kiyanagi Y
Radiat Prot Dosimetry; 2013 Mar; 153(3):369-83. PubMed ID: 22761326
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]