These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 888243)

  • 1. Improvements in electron microscopy by application of superconductivity.
    Dietrich I; Fox F; Knapek E; Lefranc G; Nachtrieb K; Weyl R; Zerbst H
    Ultramicroscopy; 1977 Apr; 2(2-3):241-9. PubMed ID: 888243
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Factors affecting high resolution fixed-beam transmission electron microscopy.
    Chiu W; Glaeser RM
    Ultramicroscopy; 1977 Apr; 2(2-3):207-17. PubMed ID: 888240
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The influence of objective lens aberrations in energy-loss spectrometry.
    Kruit P; Shuman H
    Ultramicroscopy; 1985; 17(3):263-8. PubMed ID: 4090082
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The influence of lens chromatic aberration on electron energy-loss spectroscopy quantitative measurements.
    Yang YY; Egerton RF
    Microsc Res Tech; 1992 Jun; 21(4):361-7. PubMed ID: 1638055
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Use of fast x-ray film for low-influence biological electron microscopy at 100 kV and 1000 kV.
    Parsons DF; Marko M; King MV
    J Microsc; 1980 Feb; 118(2):127-34. PubMed ID: 7359579
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Radiation damage due to knock-on processes on carbon foils cooled to liquid helium temperature.
    Dietrich I; Fox F; Heide HG; Knapek E; Weyl R
    Ultramicroscopy; 1978; 3(2):185-9. PubMed ID: 695132
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Platinum/iridium/carbon: a high-resolution shadowing material for TEM, STM and SEM of biological macromolecular structures.
    Wepf R; Amrein M; Bürkli U; Gross H
    J Microsc; 1991 Jul; 163(Pt 1):51-64. PubMed ID: 1920395
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaporated germanium films as supports for microanalysis of carbon and silicon containing specimens.
    Johansen BV; Ormstad H
    Microsc Res Tech; 1997 Sep; 38(5):519-24. PubMed ID: 9376656
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Elemental microanalysis of biological specimens.
    Roomans GM; Wroblewski J; Wróblewski R
    Scanning Microsc; 1988 Jun; 2(2):937-46. PubMed ID: 3399859
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Contribution of electron energy loss spectroscopy to the development of analytical electron microscopy.
    Colliex C; Cosslett VE; Leapman RD; Trebbia P
    Ultramicroscopy; 1976; 1(4):301-5. PubMed ID: 1028200
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transmission electron microscopic x-ray quantitative analysis of human dentin at 200 kV accelerating voltage.
    Yonehara K; Shinohara M; Kanaya K
    J Electron Microsc Tech; 1990 Nov; 16(3):240-8. PubMed ID: 2243280
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improvement of light collection efficiency of lens-coupled YAG screen TV system for a high-voltage electron microscope.
    Yamamoto K; Tanji T; Hibino M; Schauer P; Autrata R
    Microsc Res Tech; 2000 Jun; 49(6):596-604. PubMed ID: 10862116
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Elemental imaging and resolution in energy-filtered conventional electron microscopy.
    Shuman H; Chang CF; Somlyo AP
    Ultramicroscopy; 1986; 19(2):121-33. PubMed ID: 3739050
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Adaptation of a high-voltage electron microscope for routine biological dark-field imaging.
    Mannella CA; Ratkowski AJ
    Ultramicroscopy; 1983; 11(1):21-34. PubMed ID: 6193625
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Progress in aberration-corrected high-resolution transmission electron microscopy using hardware aberration correction.
    Lentzen M
    Microsc Microanal; 2006 Jun; 12(3):191-205. PubMed ID: 17481356
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Origin of artifactual quantitation of electrolytes in microprobe analysis of frozen sections of erythrocytes.
    Tormey JM; Platz RM
    Scan Electron Microsc; 1979; (2):627-34. PubMed ID: 392722
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Deconvolution of electron diffraction patterns of amorphous materials formed with convergent beam.
    McBride W; Cockayne DJ; Tsuda K
    Ultramicroscopy; 2003 Apr; 94(3-4):305-8. PubMed ID: 12524200
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Scanning image detection (SID) system for conventional transmission electron microscope (CTEM) images.
    Tanji T; Tomita M; Kobayashi H
    J Electron Microsc Tech; 1990 Aug; 15(4):397-9. PubMed ID: 2391565
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The modification of the electron microscope for special crystallographic applications.
    Dowell WC; Williams D
    Ultramicroscopy; 1976 Dec; 2(1):43-8. PubMed ID: 1028209
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Design procedure for a high resolution electron microscope objective lens.
    Tsuno K; Harada Y
    J Electron Microsc (Tokyo); 1983; 32(4):289-98. PubMed ID: 6677709
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.