BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

310 related articles for article (PubMed ID: 8883656)

  • 1. Spinal cord lesions in patients with multiple sclerosis: comparison of MR pulse sequences.
    Hittmair K; Mallek R; Prayer D; Schindler EG; Kollegger H
    AJNR Am J Neuroradiol; 1996 Sep; 17(8):1555-65. PubMed ID: 8883656
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparison of sagittal short T1 inversion recovery and T2-weighted FSE sequences for detection of multiple sclerosis spinal cord lesions.
    Nayak NB; Salah R; Huang JC; Hathout GM
    Acta Neurol Scand; 2014 Mar; 129(3):198-203. PubMed ID: 23980614
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of a conventional cardiac-triggered dual spin-echo and a fast STIR sequence in detection of spinal cord lesions in multiple sclerosis.
    Bot JC; Barkhof F; Lycklama à Nijeholt GJ; Bergers E; Polman CH; Adèr HJ; Castelijns JA
    Eur Radiol; 2000; 10(5):753-8. PubMed ID: 10823627
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Short tau inversion recovery fast spin-echo (fast STIR) imaging of the spinal cord in multiple sclerosis.
    Thorpe JW; MacManus DG; Kendall BE; Tofts PS; Barker GJ; McDonald WI; Miller DH
    Magn Reson Imaging; 1994; 12(7):983-9. PubMed ID: 7997103
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of two MR sequences for the detection of multiple sclerosis lesions in the spinal cord.
    Lycklama à Nijeholt GJ; Barkhof F; Castelijns JA; van Waesberghe JH; Valk J; Jongen PJ; Hommes OR
    AJNR Am J Neuroradiol; 1996 Sep; 17(8):1533-8. PubMed ID: 8883653
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Liver MR imaging: comparison of respiratory triggered fast spin echo with T2-weighted spin-echo and inversion recovery.
    Keogan MT; Spritzer CE; Paulson EK; Paine SS; Harris L; Dahlke JL; MacFall JR
    Abdom Imaging; 1996; 21(5):433-9. PubMed ID: 8832865
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of three MR sequences for the detection of cervical cord lesions in patients with multiple sclerosis.
    Rocca MA; Mastronardo G; Horsfield MA; Pereira C; Iannucci G; Colombo B; Moiola L; Comi G; Filippi M
    AJNR Am J Neuroradiol; 1999 Oct; 20(9):1710-6. PubMed ID: 10543646
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sagittal MR of multiple sclerosis in the spinal cord: fast versus conventional spin-echo imaging.
    Lycklama à Nijeholt GJ; Castelijns JA; Weerts J; Adèr H; van Waesberghe JH; Polman C; Barkhof F
    AJNR Am J Neuroradiol; 1998 Feb; 19(2):355-60. PubMed ID: 9504494
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The low sensitivity of fluid-attenuated inversion-recovery MR in the detection of multiple sclerosis of the spinal cord.
    Keiper MD; Grossman RI; Brunson JC; Schnall MD
    AJNR Am J Neuroradiol; 1997; 18(6):1035-9. PubMed ID: 9194430
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of MERGE and axial T2-weighted fast spin-echo sequences for detection of multiple sclerosis lesions in the cervical spinal cord.
    Martin N; Malfair D; Zhao Y; Li D; Traboulsee A; Lang D; Vertinsky AT
    AJR Am J Roentgenol; 2012 Jul; 199(1):157-62. PubMed ID: 22733907
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of conventional spin-echo and fast spin-echo in the detection of multiple sclerosis.
    Patola WB; Coulter BA; Chipperfield PM; Lingawi SS
    J Magn Reson Imaging; 2001 May; 13(5):657-67. PubMed ID: 11329186
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of Sagittal FSE T2, STIR, and T1-Weighted Phase-Sensitive Inversion Recovery in the Detection of Spinal Cord Lesions in MS at 3T.
    Alcaide-Leon P; Pauranik A; Alshafai L; Rawal S; Oh J; Montanera W; Leung G; Bharatha A
    AJNR Am J Neuroradiol; 2016 May; 37(5):970-5. PubMed ID: 26797141
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of T1-weighted fast spin-echo and T1-weighted fluid-attenuated inversion recovery images of the lumbar spine at 3.0 Tesla.
    Lavdas E; Vlychou M; Arikidis N; Kapsalaki E; Roka V; Fezoulidis IV
    Acta Radiol; 2010 Apr; 51(3):290-5. PubMed ID: 20170294
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of MRI pulse sequences for investigation of lesions of the cervical spinal cord.
    Campi A; Pontesilli S; Gerevini S; Scotti G
    Neuroradiology; 2000 Sep; 42(9):669-75. PubMed ID: 11071441
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detection of multiple sclerosis lesions in the cervical cord: which of the MAGNIMS 'mandatory' non-gadolinium enhanced sagittal sequences is optimal at 3T?
    Chang CA; Chong AL; Chandra RV; Butler E; Rajendran D; Chuah K; Stuckey S
    Neuroradiol J; 2021 Dec; 34(6):600-606. PubMed ID: 34014786
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Axial 3D gradient-echo imaging for improved multiple sclerosis lesion detection in the cervical spinal cord at 3T.
    Ozturk A; Aygun N; Smith SA; Caffo B; Calabresi PA; Reich DS
    Neuroradiology; 2013 Mar; 55(4):431-9. PubMed ID: 23208410
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Imaging of the spinal cord and brain in multiple sclerosis: a comparative study between fast FLAIR and fast spin echo.
    Stevenson VL; Gawne-Cain ML; Barker GJ; Thompson AJ; Miller DH
    J Neurol; 1997 Feb; 244(2):119-24. PubMed ID: 9120494
    [TBL] [Abstract][Full Text] [Related]  

  • 18. MR evaluation of vertebral metastases: T1-weighted, short-inversion-time inversion recovery, fast spin-echo, and inversion-recovery fast spin-echo sequences.
    Mehta RC; Marks MP; Hinks RS; Glover GH; Enzmann DR
    AJNR Am J Neuroradiol; 1995 Feb; 16(2):281-8. PubMed ID: 7726074
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of MRI sequences for evaluation of multiple sclerosis of the cervical spinal cord at 3 T.
    Philpott C; Brotchie P
    Eur J Radiol; 2011 Dec; 80(3):780-5. PubMed ID: 21041051
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fast spin-echo and fast fluid-attenuated inversion-recovery versus conventional spin-echo sequences for MR quantification of multiple sclerosis lesions.
    Bastianello S; Bozzao A; Paolillo A; Giugni E; Gasperini C; Koudriavtseva T; Millefiorini E; Horsfield MA; Colonnese C; Toni D; Fiorelli M; Pozzilli C; Bozzao L
    AJNR Am J Neuroradiol; 1997 Apr; 18(4):699-704. PubMed ID: 9127033
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.