These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 8888246)

  • 41. [In situ fibrinolysis of acute arteriovenous shunt obstructions during hemodialysis].
    Jahn C; Lebras Y; Mutter D; Petitjean P; Roy C; Schnitzler B; Dimitrov Y
    Nephrologie; 1994; 15(2):145-50. PubMed ID: 8047201
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Percutaneous interventions in subclavian artery-to-contralateral subclavian vein "necklace" hemodialysis grafts: experience in five patients.
    Fidelman N; Allen D; Bloom AI; LaBerge JM; Hastings GS; Kerlan RK; Gordon RL; Wilson MW
    J Vasc Interv Radiol; 2007 May; 18(5):597-601. PubMed ID: 17494840
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Occluded Brescia-cimino hemodialysis fistulas: endovascular treatment with both brachial arterial and venous access using the pull-through technique.
    Miyayama S; Matsui O; Taki K; Minami T; Shinmura R; Ito C; Takamatsu S; Kobayashi M; Ushiogi Y
    Cardiovasc Intervent Radiol; 2005; 28(6):806-12. PubMed ID: 16059768
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Thrombosed polytetrafluoroethylene hemodialysis fistulas: salvage with combined thrombectomy and angioplasty.
    Smith TP; Cragg AH; Castaneda F; Hunter DW
    Radiology; 1989 May; 171(2):507-8. PubMed ID: 2523081
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Treatment of thrombosed dialysis access grafts: randomized trial of surgical thrombectomy versus mechanical thrombectomy with the Amplatz device.
    Uflacker R; Rajagopalan PR; Vujic I; Stutley JE
    J Vasc Interv Radiol; 1996; 7(2):185-92. PubMed ID: 9007796
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Endovascular revascularization of chronically thrombosed arteriovenous fistulas and grafts for hemodialysis: a retrospective study in 15 patients with 18 access sites.
    Weng MJ; Chen MC; Chi WC; Liu YC; Liang HL; Pan HB
    Cardiovasc Intervent Radiol; 2011 Apr; 34(2):319-30. PubMed ID: 20585780
    [TBL] [Abstract][Full Text] [Related]  

  • 47. [Surgical experiences with the arteriovenous hemodialysis shunt (1970-1988)].
    Wehrli H; Chenevard R; Zaruba K
    Helv Chir Acta; 1989 Dec; 56(4):621-7. PubMed ID: 2632496
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Patency rates and complications of Exxcel yarn-wrapped polytetrafluoroethylene grafts versus Gore-tex stretch polytetrafluoroethylene grafts: a prospective study.
    Ko PJ; Hsieh HC; Chu JJ; Lin PJ; Liu YH
    Surg Today; 2004; 34(5):409-12. PubMed ID: 15108078
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Brachial arterial access: endovascular treatment of failing Brescia-Cimino hemodialysis fistulas--initial success and long-term results.
    Manninen HI; Kaukanen ET; Ikäheimo R; Karhapää P; Lahtinen T; Matsi P; Lampainen E
    Radiology; 2001 Mar; 218(3):711-8. PubMed ID: 11230644
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Restoration of thrombosed Brescia-Cimino dialysis fistulas by using percutaneous transluminal angioplasty.
    Liang HL; Pan HB; Chung HM; Ger LP; Fang HC; Wu TH; Wu MT; Lai PH; Chen CK; Yang CF
    Radiology; 2002 May; 223(2):339-44. PubMed ID: 11997535
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Description and outcomes of a simple surgical technique to treat thrombosed autogenous accesses.
    Cull DL; Washer JD; Carsten CG; Keahey G; Johnson B
    J Vasc Surg; 2012 Sep; 56(3):861-5. PubMed ID: 22796333
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Prosthetic axillary-axillary arteriovenous straight access (necklace graft) for difficult hemodialysis patients: a prospective single-center experience.
    Morsy MA; Khan A; Chemla ES
    J Vasc Surg; 2008 Nov; 48(5):1251-4, 1254.e1. PubMed ID: 18771891
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Adjunctive techniques to improve patency of distal prosthetic bypass grafts: polytetrafluoroethylene with remote arteriovenous fistulae versus vein cuffs.
    Kreienberg PB; Darling RC; Chang BB; Paty PS; Lloyd WE; Shah DM
    J Vasc Surg; 2000 Apr; 31(4):696-701. PubMed ID: 10753277
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Arteriovenous shunts used in hemodialysis. A retrospective study of the results in 86 patients treated during a 5-year period].
    Jensen BV; Vestersgaard-Andersen TB; Nielsen PH
    Ugeskr Laeger; 1990 Jul; 152(30):2169-71. PubMed ID: 2399585
    [TBL] [Abstract][Full Text] [Related]  

  • 55. New "mesh basket" for percutaneous removal of wall-adherent thrombi in dialysis shunts.
    Schmitz-Rode T; Bohndorf K; Günther RW
    Cardiovasc Intervent Radiol; 1993; 16(1):7-10. PubMed ID: 8435840
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Percutaneous interventions on the hemodialysis reliable outflow vascular access device.
    Gebhard TA; Bryant JA; Adam Grezaffi J; Pabon-Ramos WM; Gage SM; Miller MJ; Husum KW; Suhocki PV; Sopko DR; Lawson JH; Smith TP; Kim CY
    J Vasc Interv Radiol; 2013 Apr; 24(4):543-9. PubMed ID: 23462067
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Aspirex S catheter malfunction during arteriovenous fistula thrombectomy secondary to a jammed helix-guidewire complex.
    Kwan J; Pua U
    J Endovasc Ther; 2014 Oct; 21(5):755-9. PubMed ID: 25290806
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Endovascular Revascularization of Hemodialysis Thrombosed Grafts with the Hydrodynamic Thrombectomy Catheter. Our 7-Year Experience.
    Bermudez P; Fontseré N; Mestres G; García-Gámez A; Barrufet M; Burrel M; Gilabert R; Gómez F; Macho J
    Cardiovasc Intervent Radiol; 2017 Feb; 40(2):252-259. PubMed ID: 27896413
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Use of short PTFE segments (<6 cm) compares favorably with pure autologous repair in failing or thrombosed native arteriovenous fistulas.
    Georgiadis GS; Lazarides MK; Lambidis CD; Panagoutsos SA; Kostakis AG; Bastounis EA; Vargemezis VA
    J Vasc Surg; 2005 Jan; 41(1):76-81. PubMed ID: 15696048
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Brachiobasilic arteriovenous fistula: different surgical techniques and their effects on fistula patency and dialysis-related complications.
    Hossny A
    J Vasc Surg; 2003 Apr; 37(4):821-6. PubMed ID: 12663983
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.