These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Evaluation of radiation exposure with Tru-Align intraoral rectangular collimation system using OSL dosimeters. Goren AD; Bonvento MJ; Fernandez TJ; Abramovitch K; Zhang W; Roe N; Seltzer J; Steinberg M; Colosi DC N Y State Dent J; 2011 Mar; 77(2):24-7. PubMed ID: 21678866 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of a MOSFET radiation sensor for the measurement of entrance surface dose in diagnostic radiology. Peet DJ; Pryor MD Br J Radiol; 1999 Jun; 72(858):562-8. PubMed ID: 10560338 [TBL] [Abstract][Full Text] [Related]
7. Measurement of entrance skin dose and estimation of organ dose during pediatric chest radiography. Kumaresan M; Kumar R; Biju K; Choubey A; Kantharia S Health Phys; 2011 Jun; 100(6):654-7. PubMed ID: 22004934 [TBL] [Abstract][Full Text] [Related]
8. The effect of beam tube potential variation on gonad dose to patients during chest radiography investigated using high sensitivity LiF:Mg,Cu,P thermoluminescent dosemeters. Fung KK; Gilboy WB Br J Radiol; 2001 Apr; 74(880):358-67. PubMed ID: 11387155 [TBL] [Abstract][Full Text] [Related]
9. Characteristics of dosemeter types for skin dose measurements in practice. Van Dam J; Bosmans H; Marchal G; Wambersie A Radiat Prot Dosimetry; 2005; 117(1-3):185-9. PubMed ID: 16464834 [TBL] [Abstract][Full Text] [Related]
10. Skin and thyroid dosimetry in cervical spine screening: two methods for evaluation and a comparison between a helical CT and radiographic trauma series. Rybicki F; Nawfel RD; Judy PF; Ledbetter S; Dyson RL; Halt PS; Shu KM; Nuñez DB AJR Am J Roentgenol; 2002 Oct; 179(4):933-7. PubMed ID: 12239041 [TBL] [Abstract][Full Text] [Related]
11. Mailed thermoluminescent dosimeter determination of entrance skin exposure and half-value layer in mammography. Wochos JF; Fullerton GD; DeWerd LA AJR Am J Roentgenol; 1978 Oct; 131(4):617-9. PubMed ID: 102151 [TBL] [Abstract][Full Text] [Related]
12. Optimization of chest radiographic imaging parameters: a comparison of image quality and entrance skin dose for digital chest radiography systems. Sun Z; Lin C; Tyan Y; Ng KH Clin Imaging; 2012; 36(4):279-86. PubMed ID: 22726965 [TBL] [Abstract][Full Text] [Related]
13. Monitoring of the medical radiological exposures of the population of the Emilia-Romagna Region. Compagnone G; Angelini P; Pagan L Radiol Med; 2006 Apr; 111(3):469-80. PubMed ID: 16683092 [TBL] [Abstract][Full Text] [Related]
15. Local diagnostic reference levels for adult posteroanterior (PA) chest x-ray examination in Addis Ababa, Ethiopia. Teferi S; Admassie D; Worku A; Zewdeneh D Ethiop Med J; 2010 Jan; 48(1):49-55. PubMed ID: 20607998 [TBL] [Abstract][Full Text] [Related]
16. [Investigation of the entrance dose of standardized chest radiographs]. Stieve FE; Gfirtner H; Jung EM; Schenk G Rofo; 2004 Jan; 176(1):113-21. PubMed ID: 14712415 [TBL] [Abstract][Full Text] [Related]
17. Real-time measurement and audit of radiation dose to patients undergoing computed radiography. Vano E; Fernandez JM; Ten JI; Guibelalde E; Gonzalez L; Pedrosa CS Radiology; 2002 Oct; 225(1):283-8. PubMed ID: 12355017 [TBL] [Abstract][Full Text] [Related]
18. Bone marrow dose in chest radiography: the posteroanterior vs. anteroposterior projection. Archer BR; Whitmore RC; North LB; Bushong SC Radiology; 1979 Oct; 133(1):211-6. PubMed ID: 472293 [TBL] [Abstract][Full Text] [Related]
19. Thermoluminescent dosimeters for in vivo measurement of radiation exposure and related dose in mammography. Omran HA Radiol Technol; 1982; 53(5):383-92. PubMed ID: 6927768 [TBL] [Abstract][Full Text] [Related]
20. Computed and conventional chest radiography: a comparison of image quality and radiation dose. Ramli K; Abdullah BJ; Ng KH; Mahmud R; Hussain AF Australas Radiol; 2005 Dec; 49(6):460-6. PubMed ID: 16351609 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]