These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 889072)

  • 21. International Federation of Clinical Chemistry (IFCC). Scientific Division. Committee on pH, Blood Gases and Electrolytes. Guidelines for transcutaneous PO2 and PCO2 measurement.
    Winberley PD; Burnett RW; Covington AK; Maas AH; Mueller-Plathe O; Siggaard-Andersen O; Weisberg HF; Zijlstra WG
    Ann Biol Clin (Paris); 1990; 48(1):39-43. PubMed ID: 2306025
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Continuous monitoring of arterial oxygen tension using a catheter-tip polarographic electrode in infants.
    Conway M; Durbin GM; Ingram D; McIntosh N; Parker D; Reynolds EO; Soutter LP
    Pediatrics; 1976 Feb; 57(2):244-50. PubMed ID: 1250658
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Monitoring of arterial oxygen pressure (author's transl)].
    Kimmich HP
    Anesth Analg (Paris); 1979; 36(9-10):413-5. PubMed ID: 532997
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Clinical suitability and accuracy of a new combined system for the transcutaneous and intravascular determination of PO2.
    Kettler D; Hentze G
    Biotelem Patient Monit; 1979; 6(1-2):66-74. PubMed ID: 486727
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Transcutaneous measurement of partial pressure of oxygen and carbon dioxide.
    Franklin ML
    Respir Care Clin N Am; 1995 Sep; 1(1):119-31. PubMed ID: 9390854
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of continuous transcutaneous Po2 measurement with intermittent arterial Po2 determinations in fetal lambs.
    Mueller-Heubach E; Caritis SN; Edelstone DI; Huch R; Huch A
    Obstet Gynecol; 1981 Feb; 57(2):248-52. PubMed ID: 7465132
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Preliminary data on the clinical use of a self-constructed transcutaneous PO2 electrode during labor.
    Wladimiroff JW; von 't Hof DB; Verhoeff A; Drogendijk AC; Jansen KT
    Birth Defects Orig Artic Ser; 1979; 15(4):245-8. PubMed ID: 534703
    [No Abstract]   [Full Text] [Related]  

  • 28. Transcutaneous PO2 monitoring in routine management of infants and children with cardiorespiratory problems.
    Huch R; Huch A; Albani M; Gabriel M; Schulte FJ; Wolf H; Rupprath G; Emmrich P; Stechele U; Duc G; Bucher H
    Pediatrics; 1976 May; 57(5):681-90. PubMed ID: 940708
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Continuous intra-arterial PO2 monitoring with a surface heparinized catheter electrode. A study of conformity in conventional blood gas analysis and of long-term electrode function in the non-heparinized dog.
    Nilsson E; Edwall G; Larsson R; Olsson P
    Scand J Clin Lab Invest; 1982 Jun; 42(4):331-8. PubMed ID: 7134818
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A flexible transcutaneous oxygen sensor using polymer membranes.
    Kudo H; Iguchi S; Yamada T; Kawase T; Saito H; Otsuka K; Mitsubayashi K
    Biomed Microdevices; 2007 Feb; 9(1):1-6. PubMed ID: 17091394
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of acute hemorrhage on transcutaneous, subcutaneous, intramuscular, and arterial oxygen tensions.
    Matsen FA; Wyss CR; King RV; Simmons CW
    Pediatrics; 1980 May; 65(5):881-3. PubMed ID: 7367133
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Continuous measurement of circulating glucose using the transcutaneous PO2 electrode.
    Clark LC
    Birth Defects Orig Artic Ser; 1979; 15(4):39-42. PubMed ID: 534723
    [No Abstract]   [Full Text] [Related]  

  • 33. [Transcutaneous measurement of PaO2 by the "TCM 1" electrode (author's transl)].
    Carthaus P; Podlesch I
    Prakt Anaesth; 1979 Aug; 14(4):345-7. PubMed ID: 493230
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Pulse oximetry in very low birth weight infants with acute and chronic lung disease.
    Ramanathan R; Durand M; Larrazabal C
    Pediatrics; 1987 Apr; 79(4):612-7. PubMed ID: 2434913
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Simultaneous measurement of transcutaneous and central arterial PO2 in the acute sheep experiment.
    von 't Hof DB; Wladimiroff JW; Wallenburg HC; Drogendijk AC
    Birth Defects Orig Artic Ser; 1979; 15(4):615-9. PubMed ID: 534746
    [No Abstract]   [Full Text] [Related]  

  • 36. Is transcutaneous oxygen tension independent of variations in blood flow and in arterial blood pressure?
    Eickhoff JH; Jacobsen E
    Biotelem Patient Monit; 1982; 9(3):175-84. PubMed ID: 7159703
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Non-invasive measurement of blood oxygen levels.
    Beyerl D
    Am J Med Technol; 1982 May; 48(5):355-9. PubMed ID: 7102718
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Transcutaneous measurement of PaO2 at 37 degree C with a triple electrode system.
    Kimmich HP; Spaan JG; Kreuzer F
    Acta Anaesthesiol Scand Suppl; 1978; 68():28-32. PubMed ID: 279197
    [No Abstract]   [Full Text] [Related]  

  • 39. Transcutaneous oxygen monitoring for predicting skin viability in dogs.
    Rochat MC; Pope ER; Payne JT; Pace LW; Wagner-Mann CC
    Am J Vet Res; 1993 Mar; 54(3):468-75. PubMed ID: 8498754
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Transcutaneous oxygen monitoring in congenital diaphragmatic abnormalities.
    Gibbons M
    Nurs Crit Care; 1997; 2(3):132-7. PubMed ID: 9873314
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.