These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 8894089)

  • 1. Interfacial shear strength and histology of plasma sprayed and sintered hydroxyapatite implants in vivo.
    Wang S; Lacefield WR; Lemons JE
    Biomaterials; 1996 Oct; 17(20):1945-70. PubMed ID: 8894089
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hydroxyapatite-coated strain gauges for long-term in vivo bone strain measurements.
    Maliniak MM; Szivek JA; DeYoung DW; Emmanual J
    J Appl Biomater; 1993; 4(2):143-52. PubMed ID: 10171661
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength.
    Hayashi K; Inadome T; Tsumura H; Nakashima Y; Sugioka Y
    Biomaterials; 1994 Nov; 15(14):1187-91. PubMed ID: 7534485
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of bone-implant interface shear strength of solid hydroxyapatite and hydroxyapatite-coated titanium implants.
    Hayashi K; Inadome T; Mashima T; Sugioka Y
    J Biomed Mater Res; 1993 May; 27(5):557-63. PubMed ID: 8314808
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mechanical and histological evaluations of hydroxyapatite-coated and noncoated Ti6Al4V implants in tibia bone.
    Chang CK; Wu JS; Mao DL; Ding CX
    J Biomed Mater Res; 2001 Jul; 56(1):17-23. PubMed ID: 11309786
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The influence of residual stress on the shear strength between the bone and plasma-sprayed hydroxyapatite coating.
    Yang YC; Yang CY
    J Mater Sci Mater Med; 2008 Mar; 19(3):1051-60. PubMed ID: 17701301
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of plasma-sprayed hydroxyapatite coatings and zirconia-reinforced hydroxyapatite composite coatings: in vivo study.
    Lee TM; Yang CY; Chang E; Tsai RS
    J Biomed Mater Res A; 2004 Dec; 71(4):652-60. PubMed ID: 15505828
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A mechanical investigation of fluorapatite, magnesiumwhitlockite, and hydroxylapatite plasma-sprayed coatings in goats.
    Dhert WJ; Klein CP; Wolke JG; van der Velde EA; de Groot K; Rozing PM
    J Biomed Mater Res; 1991 Oct; 25(10):1183-200. PubMed ID: 1667400
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical and histological analysis of an HA coated, arc deposited CPTi canine hip prosthesis.
    Walenciak MT; Zimmerman MC; Harten RD; Ricci JL; Stamer DT
    J Biomed Mater Res; 1996 Aug; 31(4):465-74. PubMed ID: 8836842
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vivo evaluation of plasma-sprayed titanium coating after alkali modification.
    Xue W; Liu X; Zheng X; Ding C
    Biomaterials; 2005 Jun; 26(16):3029-37. PubMed ID: 15603798
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vitro and in vivo mechanical evaluations of plasma-sprayed hydroxyapatite coatings on titanium implants: the effect of coating characteristics.
    Yang CY; Lin RM; Wang BC; Lee TM; Chang E; Hang YS; Chen PQ
    J Biomed Mater Res; 1997 Dec; 37(3):335-45. PubMed ID: 9368138
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The shear strength and the failure mode of plasma-sprayed hydroxyapatite coating to bone: the effect of coating thickness.
    Wang BC; Lee TM; Chang E; Yang CY
    J Biomed Mater Res; 1993 Oct; 27(10):1315-27. PubMed ID: 8245046
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mechanical failure of hydroxyapatite- and polysulfone-coated titanium rods in a weight-bearing canine model.
    Shen WJ; Chung KC; Wang GJ; McLaughlin RE
    J Arthroplasty; 1992 Mar; 7(1):43-9. PubMed ID: 1314288
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanisms and structure of the bond between bone and hydroxyapatite ceramics.
    Bagambisa FB; Joos U; Schilli W
    J Biomed Mater Res; 1993 Aug; 27(8):1047-55. PubMed ID: 8408117
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mechanical and histological evaluation of amorphous calcium phosphate and poorly crystallized hydroxyapatite coatings on titanium implants.
    Maxian SH; Zawadsky JP; Dunn MG
    J Biomed Mater Res; 1993 Jun; 27(6):717-28. PubMed ID: 8408101
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Histomorphometric evaluation of the thin hydroxyapatite layer formed through anodization followed by hydrothermal treatment.
    Ishizawa H; Fujino M; Ogino M
    J Biomed Mater Res; 1997 May; 35(2):199-206. PubMed ID: 9135169
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of tissue reaction and osteointegration of metal implants between hydroxyapatite/Ti alloy coat: an animal experimental study.
    Itiravivong P; Promasa A; Laiprasert T; Techapongworachai T; Kuptniratsaikul S; Thanakit V; Heimann RB
    J Med Assoc Thai; 2003 Jun; 86 Suppl 2():S422-31. PubMed ID: 12930020
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bone attachment to hydroxyapatite coated polymers.
    Boone PS; Zimmerman MC; Gutteling E; Lee CK; Parsons JR; Langrana N
    J Biomed Mater Res; 1989 Aug; 23(A2 Suppl):183-99. PubMed ID: 2674147
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intramedullary implant of plasma-sprayed hydroxyapatite coating: an interface study.
    Yang CY; Wang BC; Lee TM; Chang E; Chang GL
    J Biomed Mater Res; 1997 Jul; 36(1):39-48. PubMed ID: 9212387
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterization of bone ingrowth and interface mechanics of a new porous 3D printed biomaterial: an animal study.
    Tanzer M; Chuang PJ; Ngo CG; Song L; TenHuisen KS
    Bone Joint J; 2019 Jun; 101-B(6_Supple_B):62-67. PubMed ID: 31146557
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.