161 related articles for article (PubMed ID: 8897343)
1. Tubal sterilization by means of selective catheterization: comparison of a hydrogel and a collagen glue.
Maubon AJ; Thurmond AS; Laurent A; Machan LS; Scanlan RM; Nikolchev J; Rouanet JP
J Vasc Interv Radiol; 1996; 7(5):733-6. PubMed ID: 8897343
[TBL] [Abstract][Full Text] [Related]
2. Selective tubal sterilization in rabbits: experience with a hydrogel combined with a sclerosing agent.
Maubon AJ; Thurmond AS; Laurent A; Honiger JE; Scanlan RM; Rouanet JP
Radiology; 1994 Dec; 193(3):721-3. PubMed ID: 7972813
[TBL] [Abstract][Full Text] [Related]
3. Tubal sterilization by selective catheterization in an animal model.
Maubon A; Rouanet JP; Laurent A; Joujoux JM; Cover S; Courtieu C; Wassef M; Godlewski G; Honiger J; Lopez FM
Invest Radiol; 1994 Feb; 29(2):156-61. PubMed ID: 8169090
[TBL] [Abstract][Full Text] [Related]
4. Experimental nonsurgical transcervical sterilization with a custom-designed platinum microcoil.
Post JH; Cardella JF; Wilson RP; Griffith JW; Fox PS; Waybill PN; Hills JR
J Vasc Interv Radiol; 1997; 8(1 Pt 1):113-8. PubMed ID: 9025049
[TBL] [Abstract][Full Text] [Related]
5. Experimental nonsurgical female sterilization: transcervical implantation of microspindles in fallopian tubes.
Schmitz-Rode T; Ross PL; Timmermans H; Thurmond AS; Günther RW; Rösch J
J Vasc Interv Radiol; 1994; 5(6):905-10. PubMed ID: 7873873
[TBL] [Abstract][Full Text] [Related]
6. Use of ethylene vinyl alcohol copolymer for tubal sterilization by selective catheterization in rabbits.
Abdala N; Levitin A; Dawson A; Maffra R; Munoz-Ramirez H; Godec K; Dolmatch BL
J Vasc Interv Radiol; 2001 Aug; 12(8):979-84. PubMed ID: 11487679
[TBL] [Abstract][Full Text] [Related]
7. Sterilization with methyl cyanoacrylate-induced fallopian tube occlusion from a nonsurgical transvaginal approach in rabbits.
Berkey GS; Nelson R; Zuckerman AM; Dillehay D; Cope C
J Vasc Interv Radiol; 1995; 6(5):669-74. PubMed ID: 8541665
[TBL] [Abstract][Full Text] [Related]
8. Characterization of tubal occlusion after transcervical polidocanol foam (PF) infusion in baboons.
Jensen JT; Hanna C; Yao S; Bauer C; Morgan TK; Slayden OD
Contraception; 2015 Aug; 92(2):96-102. PubMed ID: 26070857
[TBL] [Abstract][Full Text] [Related]
9. Occlusion of the fallopian tube by selective transcatheter radiofrequency electrocoagulation: an experimental study in rabbits.
Seo TS; Oh JH; Yoon Y; Ryu KN; Lim JW
J Vasc Interv Radiol; 2002 Apr; 13(4):399-404. PubMed ID: 11932371
[TBL] [Abstract][Full Text] [Related]
10. Transcatheter tubal sterilization in rabbits. Technique and results.
Ross PL; Thurmond AS; Uchida BT; Jones MK; Scanlan RM; Kessel E
Invest Radiol; 1994 May; 29(5):570-3. PubMed ID: 8077098
[TBL] [Abstract][Full Text] [Related]
11. Use of n-Butyl-2-Cyanoacrylate for Fallopian Tube Embolization via Selective Catheterization in a Rabbit Model: Feasibility Study for Potential Nonsurgical Sterilization.
Stewart JK; Hipolito Canario DA; Daso G; Thapa D; Montgomery S; Kohi M
J Vasc Interv Radiol; 2023 Feb; 34(2):225-233. PubMed ID: 36306987
[TBL] [Abstract][Full Text] [Related]
12. Endoscopic transvaginal approach to the rabbit uterine cervix: improvement in the technique of selective tubal catheterization.
Maubon AJ; Thurmond AS; Nikolchev J; Khera A; Machan LS; Rouanet JP
Acad Radiol; 1997 Apr; 4(4):270-4. PubMed ID: 9110024
[TBL] [Abstract][Full Text] [Related]
13. Tubal sterilization by means of endoluminal coagulation: an in vivo study in rabbits.
Spörri S; Bell B; Dreher E; Schneider H; Motamedi M
Contraception; 2000 Sep; 62(3):141-7. PubMed ID: 11124362
[TBL] [Abstract][Full Text] [Related]
14. Diode laser assisted transcervical tubal sterilization: an in vivo study in rabbits.
Spörri S; Bell B; Yandell R; Motamedi M
Lasers Surg Med; 2001; 29(4):379-85. PubMed ID: 11746117
[TBL] [Abstract][Full Text] [Related]
15. Polidocanol induced tubal occlusion in nonhuman primates: immunohistochemical detection of collagen I-V.
Slayden OD; Lee DO; Yao S; Jensen JT
Contraception; 2016 Nov; 94(5):521-526. PubMed ID: 27417518
[TBL] [Abstract][Full Text] [Related]
16. A novel technology for reversible fallopian tubal occlusion using a reverse thermo-responsive polymer-Preliminary results from a rabbit animal study.
Shveiky D; Cohn D; Elyashiv A; Nissenbaum Y; Neuman T; Karavani G; Bloom AI
Contraception; 2021 Sep; 104(3):319-323. PubMed ID: 33894249
[TBL] [Abstract][Full Text] [Related]
17. The doubtful value of transitory contraception after laparoscopic electrocoagulation of the fallopian tubes.
Kjer JJ; Lenstrup C
Acta Obstet Gynecol Scand; 1981; 60(4):403-5. PubMed ID: 6456641
[TBL] [Abstract][Full Text] [Related]
18. Effects of cornual catheterization on uterotubal histology and function.
Diamond MP; Leach RE; Ginsburg KA; El-Mowafi DM; Dawe E; Scanlan RM
Fertil Steril; 2005 Jul; 84(1):212-6. PubMed ID: 16009179
[TBL] [Abstract][Full Text] [Related]
19. Hysteroscopy and butyl-cyanoacrylate on experimental sterilization of rabbit uterine tubes.
Rivoire HC; Fagundes DJ; Bigolin S; Fagundes AT
Acta Cir Bras; 2007; 22(5):396-400. PubMed ID: 17923961
[TBL] [Abstract][Full Text] [Related]
20. Non-surgical sterilization using phenol-mucilage: acceptability versus efficacy.
Tang GW; Kwan M
Contraception; 1988 Jun; 37(6):599-606. PubMed ID: 3396359
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]