These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

412 related articles for article (PubMed ID: 8906380)

  • 1. Corneal warpage resolution after refitting an RGP contact lens wearer into hydrophilic high water content material.
    Calossi A; Verzella F; Zanella SG
    CLAO J; 1996 Oct; 22(4):242-4. PubMed ID: 8906380
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Corneal topographic changes after refitting polymethylmethacrylate contact lens wearers into rigid gas permeable materials.
    Novo AG; Pavlopoulos G; Feldman ST
    CLAO J; 1995 Jan; 21(1):47-51. PubMed ID: 7712607
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Time to resolution of contact lens-induced corneal warpage prior to refractive surgery.
    Wang X; McCulley JP; Bowman RW; Cavanagh HD
    CLAO J; 2002 Oct; 28(4):169-71. PubMed ID: 12394539
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Alteration of corneal asphericity in rigid gas permeable contact lens induced warpage.
    Maeda N; Klyce SD; Hamano H
    CLAO J; 1994 Jan; 20(1):27-31. PubMed ID: 8149570
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rigid contact lens decentration: a risk factor for corneal warpage.
    Wilson SE; Lin DT; Klyce SD; Reidy JJ; Insler MS
    CLAO J; 1990; 16(3):177-82. PubMed ID: 2379304
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Topographic changes in contact lens-induced corneal warpage.
    Wilson SE; Lin DT; Klyce SD; Reidy JJ; Insler MS
    Ophthalmology; 1990 Jun; 97(6):734-44. PubMed ID: 2374677
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Corneal topographic alterations in normal contact lens wearers.
    Ruiz-Montenegro J; Mafra CH; Wilson SE; Jumper JM; Klyce SD; Mendelson EN
    Ophthalmology; 1993 Jan; 100(1):128-34. PubMed ID: 8433817
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of contact lens wear on the corneal topography of keratoconus.
    Szczotka LB; Rabinowitz YS; Yang H
    CLAO J; 1996 Oct; 22(4):270-3. PubMed ID: 8906386
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Swelling and deswelling of rabbit corneas in response to rigid gas permeable, hydrogel and elastomer contact lens wear.
    Hideji I; MacKeen DL; Hamano H; Jester JV; Cavanagh HD
    CLAO J; 1989; 15(4):290-7. PubMed ID: 2805316
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Corneal curvature changes in soft and rigid gas permeable contact lens wearers after two years of lens wear.
    Sanaty M; Temel A
    CLAO J; 1996 Jul; 22(3):186-8. PubMed ID: 8828935
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Peripheral corneal infiltrates associated with contact lens wear.
    Suchecki JK; Ehlers WH; Donshik PC
    CLAO J; 1996 Jan; 22(1):41-6. PubMed ID: 8835068
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of corneal endothelial bleb formation and disappearance processes between rigid gas-permeable and soft contact lenses in three classes of dk/l.
    Inagaki Y; Akahori A; Sugimoto K; Kozai A; Mitsunaga S; Hamano H
    Eye Contact Lens; 2003 Oct; 29(4):234-7. PubMed ID: 14555899
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Menicon Z rigid gas permeable lenses for keratoconus and irregular corneas: a retrospective case series.
    Szczotka-Flynn LB; Patel S
    Eye Contact Lens; 2008 Sep; 34(5):254-60. PubMed ID: 18779664
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The use of computerized videokeratography as an aid in fitting rigid gas permeable contact lenses.
    Donshik PC; Reisner DS; Luistro AE
    Trans Am Ophthalmol Soc; 1996; 94():135-43; discussion 143-5. PubMed ID: 8981693
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Corneal trauma from overnight wear of rigid or soft contact lenses.
    Lin ST; Mandell RB
    J Am Optom Assoc; 1991 Mar; 62(3):224-7. PubMed ID: 1813526
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Contact lens wear after photorefractive keratectomy: comparison between rigid gas permeable and soft contact lenses.
    Lim L; Siow KL; Chong JS; Tan DT
    CLAO J; 1999 Oct; 25(4):222-7. PubMed ID: 10555738
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Differentiating contact lens induced warpage from true keratoconus using corneal topography.
    Lebow KA; Grohe RM
    CLAO J; 1999 Apr; 25(2):114-22. PubMed ID: 10344298
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The application of a computerised videokeratography (CVK) based contact lens fitting software programme on irregularly shaped corneal surfaces.
    Nosch DS; Ong GL; Mavrikakis I; Morris J
    Cont Lens Anterior Eye; 2007 Sep; 30(4):239-48. PubMed ID: 17689133
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Contact lens manipulation of corneal topography after penetrating keratoplasty: a preliminary study.
    Wilson SE; Friedman RS; Klyce SD
    CLAO J; 1992 Jul; 18(3):177-82. PubMed ID: 1499125
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mistaken diagnosis of keratoconus because of corneal warpage induced by hydrogel lens wear.
    Tseng SS; Hsiao JC; Chang DC
    Cornea; 2007 Oct; 26(9):1153-5. PubMed ID: 17893558
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.