BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 8909672)

  • 1. A simple method for frequent monitoring of gastric carbon dioxide.
    Corke CF; Prisco G; Gizycki P; Selvakumaran A
    Anaesth Intensive Care; 1996 Oct; 24(5):590-3. PubMed ID: 8909672
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Continuous assessment of gastric intramucosal PCO2 and pH in hemorrhagic shock using capnometric recirculating gas tonometry.
    Guzman JA; Kruse JA
    Crit Care Med; 1997 Mar; 25(3):533-7. PubMed ID: 9118673
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Advantage of buffered solutions or automated capnometry in air-filled balloons for use in gastric tonometry.
    Temmesfeld-Wollbrück B; Szalay A; Olschewski H; Grimminger F; Seeger W
    Intensive Care Med; 1997 Apr; 23(4):423-7. PubMed ID: 9142582
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monitoring gastric mucosal carbon dioxide pressure using gas tonometry: in vitro and in vivo validation studies.
    Creteur J; De Backer D; Vincent JL
    Anesthesiology; 1997 Sep; 87(3):504-10. PubMed ID: 9316953
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validation of air tonometric measurement of gastric regional concentrations of CO2 in critically ill septic patients.
    Heinonen PO; Jousela IT; Blomqvist KA; Olkkola KT; Takkunen OS
    Intensive Care Med; 1997 May; 23(5):524-9. PubMed ID: 9201524
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Characteristics of time-dependent PCO2 tonometry in the normal human stomach.
    Kolkman JJ; Steverink PJ; Groeneveld AB; Meuwissen SG
    Br J Anaesth; 1998 Nov; 81(5):669-75. PubMed ID: 10193274
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Tonometry of partial carbon dioxide tension in gastric mucosa: use of saline, buffer solutions, gastric juice or air.
    Groeneveld AJ
    Crit Care; 2000; 4(4):201-3. PubMed ID: 11094501
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Detection of inadvertent airway intubation during gastric tube insertion: Capnography versus a colorimetric carbon dioxide detector.
    Burns SM; Carpenter R; Blevins C; Bragg S; Marshall M; Browne L; Perkins M; Bagby R; Blackstone K; Truwit JD
    Am J Crit Care; 2006 Mar; 15(2):188-95. PubMed ID: 16501138
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Continuous gastric tonometry as a monitor of intestinal perfusion.
    Shaw AD; Baldock GJ
    Anaesthesia; 1997 Jul; 52(7):709-10. PubMed ID: 9244038
    [No Abstract]   [Full Text] [Related]  

  • 10. [PCO2 tonometry of the stomach].
    Otte JA; Kolkman JJ; Groeneveld AB
    Ned Tijdschr Geneeskd; 2000 Dec; 144(49):2341-5. PubMed ID: 11129968
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validation of air as an equilibration medium in gastric tonometry: an in vitro evaluation of two techniques for measuring air PCO2.
    Venkatesh B; Morgan J; Jones RD; Clague A
    Anaesth Intensive Care; 1998 Feb; 26(1):46-50. PubMed ID: 9513667
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vitro evaluation of intragastric PCO2 measurement by air tonometry.
    Kolkman JJ; Zwaarekant LJ; Boshuizen K; Groeneveld AB; Meuwissen SG
    J Clin Monit; 1997 Mar; 13(2):115-9. PubMed ID: 9112207
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Continuous fiberoptic PCO2 monitoring indicates poorer gastric perfusion during supraceliac aortic clamping than conventional gastric tonometry in humans: a pilot study.
    Melton A
    J Cardiothorac Vasc Anesth; 2000 Dec; 14(6):666-71. PubMed ID: 11139106
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simple technique for Capnography monitoring in COVID-19 paediatrics patient.
    Kumar N; Kumar A; Kumar A; Kumar A
    Paediatr Anaesth; 2020 Aug; 30(8):951. PubMed ID: 32959967
    [No Abstract]   [Full Text] [Related]  

  • 15. Catheter deadspace: a source of error during tonometry.
    Steverink PJ; Kolkman JJ; Groeneveld AB; de Vries JW
    Br J Anaesth; 1998 Mar; 80(3):337-41. PubMed ID: 9623434
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of temperature on gastric intramucosal PCO2 measurement by saline and air tonometry.
    Dohgomori H; Arikawa K; Kanmura Y
    J Anesth; 2003; 17(4):284-6. PubMed ID: 14625720
    [No Abstract]   [Full Text] [Related]  

  • 17. A nasal catheter for the measurement of end-tidal carbon dioxide in spontaneously breathing patients: a preliminary evaluation.
    Raheem MS; Wahba OM
    Anesth Analg; 2010 Apr; 110(4):1039-42. PubMed ID: 20357148
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Saline tonometry: comparison of Pico2 and pHi values between centers is questionable.
    Thorburn K; Baines PB
    Crit Care Med; 2001 Mar; 29(3):697-8. PubMed ID: 11373449
    [No Abstract]   [Full Text] [Related]  

  • 19. Capnography: beyond the numbers.
    Rhoades C; Thomas F
    Air Med J; 2002; 21(2):43-8. PubMed ID: 11896372
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development and validation of a technique for continuous monitoring of gastric intramucosal pH.
    Guzman JA; Kruse JA
    Am J Respir Crit Care Med; 1996 Feb; 153(2):694-700. PubMed ID: 8564119
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.