These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
161 related articles for article (PubMed ID: 8912782)
1. Improved arterial oxygenation after oleic acid lung injury in the pig using a computer-controlled mechanical ventilator. Lefevre GR; Kowalski SE; Girling LG; Thiessen DB; Mutch WA Am J Respir Crit Care Med; 1996 Nov; 154(5):1567-72. PubMed ID: 8912782 [TBL] [Abstract][Full Text] [Related]
2. Biologic variability in mechanical ventilation rate and tidal volume does not improve oxygenation or lung mechanics in canine oleic acid lung injury. Nam AJ; Brower RG; Fessler HE; Simon BA Am J Respir Crit Care Med; 2000 Jun; 161(6):1797-804. PubMed ID: 10852747 [TBL] [Abstract][Full Text] [Related]
3. A comparison of biologically variable ventilation to recruitment manoeuvres in a porcine model of acute lung injury. Funk DJ; Graham MR; Girling LG; Thliveris JA; McManus BM; Walker EK; Rector ES; Hillier C; Scott JE; Mutch WA Respir Res; 2004 Nov; 5(1):22. PubMed ID: 15563376 [TBL] [Abstract][Full Text] [Related]
4. Biologically variable ventilation increases arterial oxygenation over that seen with positive end-expiratory pressure alone in a porcine model of acute respiratory distress syndrome. Mutch WA; Harms S; Lefevre GR; Graham MR; Girling LG; Kowalski SE Crit Care Med; 2000 Jul; 28(7):2457-64. PubMed ID: 10921579 [TBL] [Abstract][Full Text] [Related]
5. Partial liquid ventilation versus conventional mechanical ventilation with high PEEP and moderate tidal volume in acute respiratory failure in piglets. Rödl S; Urlesberger B; Knez I; Dacar D; Zobel G Pediatr Res; 2002 Aug; 52(2):225-32. PubMed ID: 12149500 [TBL] [Abstract][Full Text] [Related]
6. Resolution of pulmonary edema with variable mechanical ventilation in a porcine model of acute lung injury. Graham MR; Gulati H; Kha L; Girling LG; Goertzen A; Mutch WA Can J Anaesth; 2011 Aug; 58(8):740-50. PubMed ID: 21643873 [TBL] [Abstract][Full Text] [Related]
7. [Positive end-expiratory pressure and tidal volume titration after recruitment maneuver in a canine model of acute respiratory distress syndrome]. Zhan QY; Wang C; Sun B; Pang BS Zhonghua Jie He He Hu Xi Za Zhi; 2005 Nov; 28(11):763-8. PubMed ID: 16324272 [TBL] [Abstract][Full Text] [Related]
8. Influence of tidal volume and positive end-expiratory pressure on inspiratory gas distribution and gas exchange during mechanical ventilation in horses positioned in lateral recumbency. Moens Y; Lagerweij E; Gootjes P; Poortman J Am J Vet Res; 1998 Mar; 59(3):307-12. PubMed ID: 9522950 [TBL] [Abstract][Full Text] [Related]
9. Intermittent alveolar overdistension for 30 or 240 minutes does not produce acute lung injury in normal pig lung. García-Delgado M; Navarrete-Sánchez I; Colmenero M; Touma-Fernández A; López-Cuervo JE; Hassan-Montero L; Fernández-Mondéjar E J Surg Res; 2006 Apr; 131(2):233-40. PubMed ID: 16427087 [TBL] [Abstract][Full Text] [Related]
10. Biologically variable or naturally noisy mechanical ventilation recruits atelectatic lung. Mutch WA; Harms S; Ruth Graham M; Kowalski SE; Girling LG; Lefevre GR Am J Respir Crit Care Med; 2000 Jul; 162(1):319-23. PubMed ID: 10903261 [TBL] [Abstract][Full Text] [Related]
11. Multicenter comparative study of conventional mechanical gas ventilation to tidal liquid ventilation in oleic acid injured sheep. Wolfson MR; Hirschl RB; Jackson JC; Gauvin F; Foley DS; Lamm WJ; Gaughan J; Shaffer TH ASAIO J; 2008; 54(3):256-69. PubMed ID: 18496275 [TBL] [Abstract][Full Text] [Related]
12. Partial liquid ventilation combined with two different gas ventilatory strategies in acute lung injury in piglets: Effects on gas exchange, respiratory mechanics, and hemodynamics. Zobel G; Rödl S; Urlesberger B; Knez I; Dacar D J Pediatr Surg; 2003 Apr; 38(4):527-33. PubMed ID: 12677559 [TBL] [Abstract][Full Text] [Related]
13. [The effects of endotracheal suction on gas exchange and respiratory mechanics in mechanically ventilated patients under pressure-controlled or volume-controlled ventilation]. Liu XW; Liu Z Zhonghua Jie He He Hu Xi Za Zhi; 2007 Oct; 30(10):751-5. PubMed ID: 18218205 [TBL] [Abstract][Full Text] [Related]
14. Low tidal volume and high positive end-expiratory pressure mechanical ventilation results in increased inflammation and ventilator-associated lung injury in normal lungs. Hong CM; Xu DZ; Lu Q; Cheng Y; Pisarenko V; Doucet D; Brown M; Aisner S; Zhang C; Deitch EA; Delphin E Anesth Analg; 2010 Jun; 110(6):1652-60. PubMed ID: 20103541 [TBL] [Abstract][Full Text] [Related]
15. [Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment]. Fösel T; Schirmer U; Wick C; Pfenninger E; Siegler W; Altemeyer KH Anaesthesist; 1991 Nov; 40(11):624-8. PubMed ID: 1755533 [TBL] [Abstract][Full Text] [Related]
16. Effects of frequency and airway pressure on gas exchange during interrupted high-frequency, positive-pressure ventilation in ponies. Wilson DV; Suslak L; Soma LR Am J Vet Res; 1988 Aug; 49(8):1263-9. PubMed ID: 3052192 [TBL] [Abstract][Full Text] [Related]
17. Mechanical ventilation during cardiopulmonary resuscitation with intermittent positive-pressure ventilation, bilevel ventilation, or chest compression synchronized ventilation in a pig model. Kill C; Hahn O; Dietz F; Neuhaus C; Schwarz S; Mahling R; Wallot P; Jerrentrup A; Steinfeldt T; Wulf H; Dersch W Crit Care Med; 2014 Feb; 42(2):e89-95. PubMed ID: 24158168 [TBL] [Abstract][Full Text] [Related]
18. Compliance, blood gases, and acid-base balance in guinea pigs artificially ventilated with different IPPV patterns. Kluge R Acta Physiol Hung; 1987; 70(2-3):297-302. PubMed ID: 3124501 [TBL] [Abstract][Full Text] [Related]
19. [Hemodynamic effects of synchronous and asynchronous independent lung ventilation with different levels of positive end-expiratory pressure and tidal volumes on unilateral lung injury in dogs]. Bu XN; Cao ZX; Pang BS; Wang S; Wang C Zhonghua Jie He He Hu Xi Za Zhi; 2010 Oct; 33(10):766-70. PubMed ID: 21176509 [TBL] [Abstract][Full Text] [Related]
20. High peak inspiratory flow can aggravate ventilator-induced lung injury in rabbits. Fujita Y; Fujino Y; Uchiyama A; Mashimo T; Nishimura M Med Sci Monit; 2007 Apr; 13(4):BR95-100. PubMed ID: 17392642 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]