These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 8914183)

  • 1. Erosion of a mesenteric vessel by a Tenckhoff catheter.
    Miller R; Denman R; Saltissi D; Healy H; Muller M; Fleming S
    Perit Dial Int; 1996; 16(5):528-9. PubMed ID: 8914183
    [No Abstract]   [Full Text] [Related]  

  • 2. Massive hemoperitoneum due to spleen injury by a dislocated Tenckhoff catheter.
    Van der Niepen P; Sennesael JJ; Verbeelen DL
    Perit Dial Int; 1994; 14(1):90-1. PubMed ID: 8312427
    [No Abstract]   [Full Text] [Related]  

  • 3. Tenckhoff peritoneal dialysis catheters: the use of fluoroscopy in management.
    Degesys GE; Miller GA; Ford KK; Dunnick NR
    Radiology; 1985 Mar; 154(3):819-20. PubMed ID: 3969488
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Continuous ambulatory peritoneal dialysis. 1. The catheter for CAPD].
    Sánchez Zaplana I; Buj A
    Rev Enferm; 1988 Dec; 11(124):52-6. PubMed ID: 3231979
    [No Abstract]   [Full Text] [Related]  

  • 5. Interchangeable abdominal catheter for peritoneal dialysis.
    Cavagna R; Casol D; De Paoli Vitali E; Tessarin C; Bandiani G; Camaiora E; Nicolini MA; Perotta V
    Int J Artif Organs; 1981 Mar; 4(2):108. PubMed ID: 7275328
    [No Abstract]   [Full Text] [Related]  

  • 6. The straight Tenckhoff catheter.
    Colombi A; Ayer G; Burri G
    Contrib Nephrol; 1991; 89():31-4. PubMed ID: 1893737
    [No Abstract]   [Full Text] [Related]  

  • 7. Catheter-related complications during continuous ambulatory peritoneal dialysis (CAPD): a retrospective study on sixty-two double-cuff Tenckhoff catheters.
    Vogt K; Binswanger U; Buchmann P; Baumgartner D; Keusch G; Largiadèr F
    Am J Kidney Dis; 1987 Jul; 10(1):47-51. PubMed ID: 3605083
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of two catheters for peritoneal access in patients undergoing continuous ambulatory peritoneal dialysis (CAPD).
    Grefberg N; Danielson BG; Nilsson P; Wahlberg J
    Scand J Urol Nephrol; 1983; 17(3):343-6. PubMed ID: 6648382
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Three years of experience with the swan-neck Tenckhoff catheter.
    Nebel M; Marczewski K; Finke K
    Adv Perit Dial; 1991; 7():208-13. PubMed ID: 1680427
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Structural defects in chronic peritoneal dialysis catheters contributing to peritonitis.
    Roxe DM; Santhanam S
    Nephron; 1983; 34(4):267-8. PubMed ID: 6877463
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A simple method to prevent peritoneal dialysis catheter tip migration.
    Chen WM; Cheng CL
    Perit Dial Int; 2007; 27(5):554-6. PubMed ID: 17704446
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Complications after tenckhoff catheter insertion: a single-centre experience using multiple operators over four years.
    Liu WJ; Hooi LS
    Perit Dial Int; 2010; 30(5):509-12. PubMed ID: 20228175
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hemoperitoneum in patients receiving hemodialysis.
    Stolz A; Fourcade J; Klisnick A; Souweine B; Abergel A; Baguet JC; Deteix P
    Am J Kidney Dis; 2000 Aug; 36(2):E11. PubMed ID: 10922332
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rupture of ovarian cyst: massive hemoperitoneum in continuous ambulatory peritoneal dialysis patients: diagnosis and treatment.
    Fraley DS; Johnston JR; Bruns FJ; Adler S; Segel DP
    Am J Kidney Dis; 1988 Jul; 12(1):69-71. PubMed ID: 3389357
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Identification of peritoneal dialysis catheter tunnel infection by scanning with Indium-111-labeled leukocytes.
    Steiner RW; Kipper S; Savoia MC; Witztum KF
    Ann Intern Med; 1983 Jul; 99(1):44-5. PubMed ID: 6859724
    [No Abstract]   [Full Text] [Related]  

  • 16. Mycobacterium phlei peritonitis: a rare complication of chronic peritoneal dialysis.
    Paul E; Devarajan P
    Pediatr Nephrol; 1998 Jan; 12(1):67-8. PubMed ID: 9502573
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design criteria for artificial percutaneous leads, with emphasis on the comparison between the Tenckhoff catheter and the Berlin catheter.
    Becker H; Schurig R; Gahl GM; Grosse-Siestrup C; Affeld K; Weihermüller K; Hain H
    Contrib Nephrol; 1987; 57():136-46. PubMed ID: 3677687
    [No Abstract]   [Full Text] [Related]  

  • 18. Surgical complications of Tenckhoff catheters used in continuous ambulatory peritoneal dialysis.
    Tiong HY; Poh J; Sunderaraj K; Wu YJ; Consigliere DT
    Singapore Med J; 2006 Aug; 47(8):707-11. PubMed ID: 16865213
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Laparoscopic repositioning of malfunctioning peritoneal dialysis catheters.
    Kittur DS; Gazaway PM; Abidin MR
    Surg Laparosc Endosc; 1991 Sep; 1(3):179-82. PubMed ID: 1669399
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Peritoneal dialysis access: prospective randomized comparison of single-cuff and double-cuff straight Tenckhoff catheters.
    Eklund B; Honkanen E; Kyllönen L; Salmela K; Kala AR
    Nephrol Dial Transplant; 1997 Dec; 12(12):2664-6. PubMed ID: 9430868
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.