These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 8914569)

  • 21. A comparison of a new reflectance oximeter with the Hewlett-Packard ear oximeter.
    Decker MJ; Dickensheets D; Arnold JL; Cheung PW; Strohl KP
    Biomed Instrum Technol; 1990; 24(2):122-6. PubMed ID: 2322755
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Simultaneous comparison of three noninvasive oximeters in healthy volunteers.
    Mendelson Y; Kent JC; Shahnarian A; Welch GW; Giasi RM
    Med Instrum; 1987 Jun; 21(3):183-8. PubMed ID: 3614041
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Pulse Oximeter Performance, Racial Inequity, and the Work Ahead.
    Okunlola OE; Lipnick MS; Batchelder PB; Bernstein M; Feiner JR; Bickler PE
    Respir Care; 2022 Feb; 67(2):252-257. PubMed ID: 34772785
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Reflectance pulse oximetry from core body in neonates and infants: comparison to arterial blood oxygen saturation and to transmission pulse oximetry.
    Kugelman A; Wasserman Y; Mor F; Goldinov L; Geller Y; Bader D
    J Perinatol; 2004 Jun; 24(6):366-71. PubMed ID: 15057251
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Pulse oximeter accuracy and precision affected by sensor location in cyanotic children.
    Sedaghat-Yazdi F; Torres A; Fortuna R; Geiss DM
    Pediatr Crit Care Med; 2008 Jul; 9(4):393-7. PubMed ID: 18496398
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pulse oximetry: evaluation of accuracy during outpatient general anesthesia for oral surgery.
    Anderson JA; Lambert DM; Kafer ER; Dolan P
    Anesth Prog; 1988; 35(2):53-60. PubMed ID: 3166346
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Potential errors in pulse oximetry. I. Pulse oximeter evaluation.
    Ralston AC; Webb RK; Runciman WB
    Anaesthesia; 1991 Mar; 46(3):202-6. PubMed ID: 2014898
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Noninvasive oximetry in pigmented patients.
    Wang YT; Poh SC
    Ann Acad Med Singap; 1985 Jul; 14(3):427-9. PubMed ID: 4073807
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Precision of noninvasive hemoglobin-level measurement by pulse co-oximetry in patients admitted to intensive care units for severe gastrointestinal bleeds.
    Coquin J; Dewitte A; Manach YL; Caujolle M; Joannes-Boyau O; Fleureau C; Janvier G; Ouattara A
    Crit Care Med; 2012 Sep; 40(9):2576-82. PubMed ID: 22732278
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Accuracy of pulse oximeter readings from probe placement on newborn wrist and ankle.
    Phattraprayoon N; Sardesai S; Durand M; Ramanathan R
    J Perinatol; 2012 Apr; 32(4):276-80. PubMed ID: 21738120
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Pulse oximetry in very low birth weight infants with acute and chronic lung disease.
    Ramanathan R; Durand M; Larrazabal C
    Pediatrics; 1987 Apr; 79(4):612-7. PubMed ID: 2434913
    [TBL] [Abstract][Full Text] [Related]  

  • 32. An in vivo investigation of photoplethysmographic signals and preliminary pulse oximetry estimation from the bowel using a new fiberoptic sensor.
    Hickey M; Samuels N; Randive N; Langford RM; Kyriacou PA
    Anesth Analg; 2011 May; 112(5):1104-9. PubMed ID: 21346164
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A comparison of the performance of 20 pulse oximeters under conditions of poor perfusion.
    Clayton DG; Webb RK; Ralston AC; Duthie D; Runciman WB
    Anaesthesia; 1991 Jan; 46(1):3-10. PubMed ID: 1996749
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Accuracy of pulse oximetry in children.
    Ross PA; Newth CJ; Khemani RG
    Pediatrics; 2014 Jan; 133(1):22-9. PubMed ID: 24344108
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A comparison of two pulse oximeters. Assessment of accuracy at low arterial saturation in paediatric surgical patients.
    Ridley SA
    Anaesthesia; 1988 Feb; 43(2):136-40. PubMed ID: 3354809
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Effect of dyshemoglobinemia (methemoglobinemia and carboxyhemoglobinemia) on accuracy of measurement in pulse oximetry in operations of long duration].
    Michaelis G; Biscoping J; Sälzer A; Hempelmann G
    Anasth Intensivther Notfallmed; 1988 Apr; 23(2):102-8. PubMed ID: 3394901
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Accuracy of two ear oximeters at rest and during exercise in pulmonary patients.
    Ries AL; Farrow JT; Clausen JL
    Am Rev Respir Dis; 1985 Sep; 132(3):685-9. PubMed ID: 4037542
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patients.
    Hinkelbein J; Genzwuerker HV; Sogl R; Fiedler F
    Resuscitation; 2007 Jan; 72(1):82-91. PubMed ID: 17098347
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis.
    Shi C; Goodall M; Dumville J; Hill J; Norman G; Hamer O; Clegg A; Watkins CL; Georgiou G; Hodkinson A; Lightbody CE; Dark P; Cullum N
    BMC Med; 2022 Aug; 20(1):267. PubMed ID: 35971142
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The efficacy of noninvasive hemoglobin measurement by pulse CO-oximetry in neonates.
    Jung YH; Lee J; Kim HS; Shin SH; Sohn JA; Kim EK; Choi JH
    Pediatr Crit Care Med; 2013 Jan; 14(1):70-3. PubMed ID: 23132397
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.