186 related articles for article (PubMed ID: 8916495)
1. Doppler derivation of complete pulmonary artery pressure curves in patent ductus arteriosus.
Becker TE; Ensing GJ; Darragh RK; Caldwell RL
Am J Cardiol; 1996 Nov; 78(9):1066-9. PubMed ID: 8916495
[TBL] [Abstract][Full Text] [Related]
2. Doppler echocardiographic flow characteristics of isolated patent ductus arteriosus: better delineation by Doppler color flow mapping.
Liao PK; Su WJ; Hung JS
J Am Coll Cardiol; 1988 Nov; 12(5):1285-91. PubMed ID: 3170973
[TBL] [Abstract][Full Text] [Related]
3. Diagnosis of patent ductus arteriosus in adults by biplane transesophageal color Doppler flow mapping.
Takenaka K; Sakamoto T; Shiota T; Amano W; Igarashi T; Sugimoto T
Am J Cardiol; 1991 Sep; 68(6):691-3. PubMed ID: 1877494
[No Abstract] [Full Text] [Related]
4. [Measurement by Doppler echocardiography of the pulmonary arterial pressure in children with ductus arteriosus. Simultaneous Doppler and hemodynamic study].
Cloez JL; Isaaz K; Marchal C; Morizot D; Pernot C
Arch Mal Coeur Vaiss; 1986 May; 79(5):719-24. PubMed ID: 3092772
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of pulmonary arterial pressure by Doppler colour flow mapping in patients with a ductus arteriosus.
Aziz K; Tasneem H
Br Heart J; 1990 May; 63(5):295-9. PubMed ID: 2278800
[TBL] [Abstract][Full Text] [Related]
6. [Non-invasive assessment of the peak pressure gradient between the aorta and pulmonary artery in patent ductus arteriosus].
Nakajima T; Arakaki Y; Shimizu T; Sato I; Futaki S; Kamiya T; Miyatake K; Nimura Y
J Cardiol; 1987 Jun; 17(2):353-60. PubMed ID: 3329223
[TBL] [Abstract][Full Text] [Related]
7. Pulmonary artery size and flow disturbances after patent ductus arteriosus coil occlusion.
Carey LM; Vermilion RP; Shim D; Lloyd TT; Beekman RH; Ludomirsky A
Am J Cardiol; 1996 Dec; 78(11):1307-10. PubMed ID: 8960599
[TBL] [Abstract][Full Text] [Related]
8. Pulsatile aortopulmonary pressure-flow dynamics of patent ductus arteriosus in patients with various hemodynamic states.
Spach MS; Serwer GA; Anderson PA; Canent RV; Levin AR
Circulation; 1980 Jan; 61(1):110-22. PubMed ID: 7349924
[No Abstract] [Full Text] [Related]
9. [Noninvasive estimation of the pulmonary artery pressures in patent ductus arteriosus with continuous-wave Doppler echocardiography].
Zhang Y; Ge ZM; Fan DS
Zhonghua Nei Ke Za Zhi; 1992 Oct; 31(10):614-6, 657. PubMed ID: 1306452
[TBL] [Abstract][Full Text] [Related]
10. Medium-term follow up of residual shunting and potential complications after transcatheter occlusion of the ductus arteriosus.
Magee AG; Stumper O; Burns JE; Godman MJ
Br Heart J; 1994 Jan; 71(1):63-9. PubMed ID: 8297698
[TBL] [Abstract][Full Text] [Related]
11. Real-time Doppler color flow mapping for detection of patent ductus arteriosus.
Swensson RE; Valdes-Cruz LM; Sahn DJ; Sherman FS; Chung KJ; Scagnelli S; Hagen-Ansert S
J Am Coll Cardiol; 1986 Nov; 8(5):1105-12. PubMed ID: 3531287
[TBL] [Abstract][Full Text] [Related]
12. Doppler flow characteristics in the assessment of pulmonary artery pressure in ductus arteriosus.
Houston AB; Lim MK; Doig WB; Gnanapragasam J; Coleman EN; Jamieson MP; Pollock JC
Br Heart J; 1989 Oct; 62(4):284-90. PubMed ID: 2803875
[TBL] [Abstract][Full Text] [Related]
13. Noninvasive Doppler echocardiographic evaluation of shunt flow dynamics of the ductus arteriosus.
Hiraishi S; Horiguchi Y; Misawa H; Oguchi K; Kadoi N; Fujino N; Yashiro K
Circulation; 1987 Jun; 75(6):1146-53. PubMed ID: 3568325
[TBL] [Abstract][Full Text] [Related]
14. Single Doppler detection of left to right shunt through the ductus arteriosus.
Mellander M; Sabel KG; Mellgren G
Acta Paediatr Scand Suppl; 1986; 329():98-102. PubMed ID: 3473909
[TBL] [Abstract][Full Text] [Related]
15. Pulmonary artery velocity patterns in ductus arteriosus.
Wilson N; Dickinson DF; Goldberg SJ; Scott O
Br Heart J; 1984 Oct; 52(4):462-4. PubMed ID: 6477786
[TBL] [Abstract][Full Text] [Related]
16. Validation of Doppler-derived pulmonary arterial pressure in patients with ductus arteriosus under different hemodynamic states.
Musewe NN; Smallhorn JF; Benson LN; Burrows PE; Freedom RM
Circulation; 1987 Nov; 76(5):1081-91. PubMed ID: 2959394
[TBL] [Abstract][Full Text] [Related]
17. Quantitative, noninvasive assessment of patent ductus arteriosus shunt flow by measuring proximal isovelocity surface area on color Doppler imaging.
Iwashima S; Ishikawa T
Circ J; 2014; 78(9):2302-8. PubMed ID: 25008486
[TBL] [Abstract][Full Text] [Related]
18. Capillary refilling time and hemodynamics in neonates: a Doppler echocardiographic evaluation.
Wodey E; Pladys P; Bétrémieux P; Kerebel C; Ecoffey C
Crit Care Med; 1998 Aug; 26(8):1437-40. PubMed ID: 9710106
[TBL] [Abstract][Full Text] [Related]
19. [Pulsatile flow dynamics of the ductus arteriosus, thoracic aorta and pulmonary artery in patients with patent ductus arteriosus].
Nakano H; Saito A; Ueda K
J Cardiogr; 1983 Sep; 13(3):715-29. PubMed ID: 6678299
[TBL] [Abstract][Full Text] [Related]
20. Does ductal occlusion with the gianturco coil cause left pulmonary artery and/or descending aorta obstruction?
Stromberg D; Pignatelli R; Rosenthal GL; Ing FF
Am J Cardiol; 1999 Apr; 83(8):1229-35. PubMed ID: 10215290
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]