105 related articles for article (PubMed ID: 8917187)
1. Influence of collimator characteristics on quantification in SPECT.
Fleming JS; Alaamer AS
J Nucl Med; 1996 Nov; 37(11):1832-6. PubMed ID: 8917187
[TBL] [Abstract][Full Text] [Related]
2. Validation of the Yale circumferential quantification method using 201Tl and 99mTc: a phantom study.
Kirac S; Wackers FJ; Liu YH
J Nucl Med; 2000 Aug; 41(8):1436-41. PubMed ID: 10945538
[TBL] [Abstract][Full Text] [Related]
3. Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system.
Seo Y; Wong KH; Sun M; Franc BL; Hawkins RA; Hasegawa BH
J Nucl Med; 2005 May; 46(5):868-77. PubMed ID: 15872362
[TBL] [Abstract][Full Text] [Related]
4. SPECT imaging of fluorine-18.
Leichner PK; Morgan HT; Holdeman KP; Harrison KA; Valentino F; Lexa R; Kelly RF; Hawkins WG; Dalrymple GV
J Nucl Med; 1995 Aug; 36(8):1472-5. PubMed ID: 7629597
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of penetration and scattering components in conventional pinhole SPECT: phantom studies using Monte Carlo simulation.
Deloar HM; Watabe H; Aoi T; Iida H
Phys Med Biol; 2003 Apr; 48(8):995-1008. PubMed ID: 12741497
[TBL] [Abstract][Full Text] [Related]
6. System characteristics of SPECT with a slat collimated strip detector.
Vandenberghe S; Van Holen R; Staelens S; Lemahieu I
Phys Med Biol; 2006 Jan; 51(2):391-405. PubMed ID: 16394346
[TBL] [Abstract][Full Text] [Related]
7. Accurate Monte Carlo modelling of the back compartments of SPECT cameras.
Rault E; Staelens S; Van Holen R; De Beenhouwer J; Vandenberghe S
Phys Med Biol; 2011 Jan; 56(1):87-104. PubMed ID: 21119230
[TBL] [Abstract][Full Text] [Related]
8. Slit slat collimator optimization with respect to MTF.
Kamali-Asl A; Sarkar S; Shahriari M; Agha-Hosseini H
Appl Radiat Isot; 2005 Mar; 62(3):461-8. PubMed ID: 15607925
[TBL] [Abstract][Full Text] [Related]
9. Analytical derivation of the point spread function for pinhole collimators.
Bal G; Acton PD
Phys Med Biol; 2006 Oct; 51(19):4923-50. PubMed ID: 16985279
[TBL] [Abstract][Full Text] [Related]
10. Monte Carlo modeling of gamma cameras for I-131 imaging in targeted radiotherapy.
Autret D; Bitar A; Ferrer L; Lisbona A; Bardiès M
Cancer Biother Radiopharm; 2005 Feb; 20(1):77-84. PubMed ID: 15778585
[TBL] [Abstract][Full Text] [Related]
11. Fast hybrid SPECT simulation including efficient septal penetration modelling (SP-PSF).
Staelens S; de Wit T; Beekman F
Phys Med Biol; 2007 Jun; 52(11):3027-43. PubMed ID: 17505087
[TBL] [Abstract][Full Text] [Related]
12. Comparison of low- and medium-energy collimators for SPECT imaging with iodine-123-labeled antibodies.
Macey DJ; DeNardo GL; DeNardo SJ; Hines HH
J Nucl Med; 1986 Sep; 27(9):1467-74. PubMed ID: 3489084
[TBL] [Abstract][Full Text] [Related]
13. Half-fanbeam collimators combined with scanning point sources for simultaneous emission-transmission imaging.
Beekman FJ; Kamphuis C; Hutton BF; van Rijk PP
J Nucl Med; 1998 Nov; 39(11):1996-2003. PubMed ID: 9829597
[TBL] [Abstract][Full Text] [Related]
14. Nonistropic point spread function as a result of collimator design and manufacturing defects.
Gillen GJ; Hilditch TE; Elliott AT
J Nucl Med; 1988 Jun; 29(6):1096-100. PubMed ID: 3259626
[TBL] [Abstract][Full Text] [Related]
15. Photon energy recovery: a method to improve the effective energy resolution of gamma cameras.
Hannequin PP; Mas JF
J Nucl Med; 1998 Mar; 39(3):555-62. PubMed ID: 9529311
[TBL] [Abstract][Full Text] [Related]
16. On-axis sensitivity and resolution of a slit-slat collimator.
Metzler SD; Accorsi R; Novak JR; Ayan AS; Jaszczak RJ
J Nucl Med; 2006 Nov; 47(11):1884-90. PubMed ID: 17079823
[TBL] [Abstract][Full Text] [Related]
17. Septal penetration correction in I-131 imaging following thyroid cancer treatment.
Barrack F; Scuffham J; McQuaid S
Phys Med Biol; 2018 Mar; 63(7):075012. PubMed ID: 29465414
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of high-resolution pinhole SPECT using a small rotating animal.
Habraken JB; de Bruin K; Shehata M; Booij J; Bennink R; van Eck Smit BL; Busemann Sokole E
J Nucl Med; 2001 Dec; 42(12):1863-9. PubMed ID: 11752086
[TBL] [Abstract][Full Text] [Related]
19. Collimator angulation error and its effect on SPECT.
Malmin RE; Stanley PC; Guth WR
J Nucl Med; 1990 May; 31(5):655-9. PubMed ID: 2341901
[TBL] [Abstract][Full Text] [Related]
20. [Scatter Correction of Septal Penetration for
Yamanaga T; Katayama Y; Nakama S; Kakimi A; Nagahata T; Kishimoto K; Ichida T; Higashiyama S; Kawabe J; Shiomi S
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2017; 73(10):1028-1038. PubMed ID: 29057774
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]