These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 8918215)

  • 1. Slurry preparation by high-pressure homogenization for the determination of heavy metals in zoological and botanical certified reference materials and animal feeds by electrothermal atomic absorption spectrometry.
    Tan Y; Blais JS; Marshall WD
    Analyst; 1996 Oct; 121(10):1419-24. PubMed ID: 8918215
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Slurry preparation by high-pressure homogenization for cadmium, copper and lead determination in cervine liver and kidney by electrothermal atomic absorption spectrometry.
    Tan Y; Marshall WD; Blais JS
    Analyst; 1996 Apr; 121(4):483-8. PubMed ID: 8633793
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Enzymatic digestion-high-pressure homogenization prior to slurry introduction graphite furnace atomic absorption spectrometry for selenium determination in plant and animal tissues.
    Chen X; Marshall WD
    J Agric Food Chem; 1999 Sep; 47(9):3727-32. PubMed ID: 10552713
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of selenium in marine biological tissues by transverse heated electrothermal atomic absorption spectrometry with longitudinal Zeeman background correction and automated ultrasonic slurry sampling.
    Méndez H; Alava F; Lavilla I; Bendicho C
    J AOAC Int; 2001; 84(6):1921-6. PubMed ID: 11767163
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of zinc in tissues of normal and dystrophic mice using electrothermal atomic absorption spectrometry and slurry sampling.
    Muñoz-Delgado E; Morote-García JC; Romero-Romero R; López-García I; Hernández-Córdoba M
    Anal Biochem; 2006 Jan; 348(1):64-8. PubMed ID: 16289445
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Slurry sampling graphite furnace atomic absorption spectrometry: determination of trace metals in mineral coal.
    Silva MM; Goreti M; Vale R; Caramão EB
    Talanta; 1999 Dec; 50(5):1035-43. PubMed ID: 18967798
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparative determination of Ba, Cu, Fe, Pb and Zn in tea leaves by slurry sampling electrothermal atomic absorption and liquid sampling inductively coupled plasma atomic emission spectrometry.
    Mierzwa J; Sun YC; Chung YT; Yang MH
    Talanta; 1998 Dec; 47(5):1263-70. PubMed ID: 18967432
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of microwave digestion and solvent extraction for the determination of trace amounts of selenium in feeds and plant and animal tissues by electrothermal atomic absorption spectrometry.
    Hocquellet P; Candillier MP
    Analyst; 1991 May; 116(5):505-9. PubMed ID: 1877754
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of copper, cobalt, nickel, and manganese in baby food slurries using electrothermal atomic absorption spectrometry.
    Viñas P; Pardo-Martínez M; Hernández-Córdoba M
    J Agric Food Chem; 2000 Dec; 48(12):5789-94. PubMed ID: 11141250
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mineral content in legumes and nuts: contribution to the Spanish dietary intake.
    Cabrera C; Lloris F; Giménez R; Olalla M; López MC
    Sci Total Environ; 2003 Jun; 308(1-3):1-14. PubMed ID: 12738197
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomonitoring of essential and toxic metals in single hair using on-line solution-based calibration in laser ablation inductively coupled plasma mass spectrometry.
    Dressler VL; Pozebon D; Mesko MF; Matusch A; Kumtabtim U; Wu B; Sabine Becker J
    Talanta; 2010 Oct; 82(5):1770-7. PubMed ID: 20875575
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The use of electrothermal vaporizer coupled to the inductively coupled plasma mass spectrometry for the determination of arsenic, selenium and transition metals in biological samples treated with formic acid.
    Tormen L; Gil RA; Frescura VL; Martinez LD; Curtius AJ
    Anal Chim Acta; 2012 Mar; 717():21-7. PubMed ID: 22304812
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Light-induced pH change and its application to solid phase extraction of trace heavy metals by high-magnetization Fe3O4@SiO2@TiO2 nanoparticles followed by inductively coupled plasma mass spectrometry detection.
    Zhang N; Peng H; Hu B
    Talanta; 2012 May; 94():278-83. PubMed ID: 22608448
    [TBL] [Abstract][Full Text] [Related]  

  • 14. External calibration strategy for trace element quantification in botanical samples by LA-ICP-MS using filter paper.
    Nunes MA; Voss M; Corazza G; Flores EM; Dressler VL
    Anal Chim Acta; 2016 Jan; 905():51-7. PubMed ID: 26755136
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The use of slurry sampling for the determination of manganese and copper in various samples by electrothermal atomic absorption spectrometry.
    Tokman N
    J Hazard Mater; 2007 May; 143(1-2):87-94. PubMed ID: 17030426
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of macro and trace elements in multivitamin dietary supplements by high-resolution continuum source graphite furnace atomic absorption spectrometry with slurry sampling.
    Krawczyk M
    J Pharm Biomed Anal; 2014 Jan; 88():377-84. PubMed ID: 24176741
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simultaneous determination of Cd, Cu, Mn, Ni, Pb and Zn in nail samples by inductively coupled plasma mass spectrometry (ICP-MS) after tetramethylammonium hydroxide solubilization at room temperature: comparison with ETAAS.
    Batista BL; Rodrigues JL; Nunes JA; Tormen L; Curtius AJ; Barbosa F
    Talanta; 2008 Jul; 76(3):575-9. PubMed ID: 18585323
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of mercury in sewage sludges by slurry sampling electrothermal atomic absorption spectrometry.
    López-García I; Sánchez-Merlos M; Arroyo-Cortez J; Hernández-Córdoba M
    J AOAC Int; 2002; 85(1):25-30. PubMed ID: 11878609
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of vanadium in mussels by electrothermal atomic absorption spectrometry without chemical modifiers.
    Saavedra Y; Fernández P; González A
    Anal Bioanal Chem; 2004 May; 379(1):72-6. PubMed ID: 14745471
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of Cd, Cr, Cu, Ni, and Pb in selected cosmetic products from Jordanian, Sudanese, and Syrian markets.
    Massadeh AM; El-Khateeb MY; Ibrahim SM
    Public Health; 2017 Aug; 149():130-137. PubMed ID: 28628796
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.