These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
297 related articles for article (PubMed ID: 8923082)
21. Oxygen Fick and modified carbon dioxide Fick cardiac outputs. Mahutte CK; Jaffe MB; Chen PA; Sasse SA; Wong DH; Sassoon CS Crit Care Med; 1994 Jan; 22(1):86-95. PubMed ID: 8124981 [TBL] [Abstract][Full Text] [Related]
22. Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis. Kouz K; Michard F; Bergholz A; Vokuhl C; Briesenick L; Hoppe P; Flick M; Schön G; Saugel B Crit Care; 2021 Mar; 25(1):125. PubMed ID: 33781307 [TBL] [Abstract][Full Text] [Related]
23. Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions. Della Rocca G; Costa MG; Chiarandini P; Bertossi G; Lugano M; Pompei L; Coccia C; Sainz-Barriga M; Pietropaoli P J Cardiothorac Vasc Anesth; 2008 Oct; 22(5):681-7. PubMed ID: 18922423 [TBL] [Abstract][Full Text] [Related]
24. Multicenter study verifying a method of noninvasive continuous cardiac output measurement using pulse wave transit time: a comparison with intermittent bolus thermodilution cardiac output. Yamada T; Tsutsui M; Sugo Y; Sato T; Akazawa T; Sato N; Yamashita K; Ishihara H; Takeda J Anesth Analg; 2012 Jul; 115(1):82-7. PubMed ID: 22467885 [TBL] [Abstract][Full Text] [Related]
25. Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: a prospective criterion standard study. Haller M; Zöllner C; Briegel J; Forst H Crit Care Med; 1995 May; 23(5):860-6. PubMed ID: 7736744 [TBL] [Abstract][Full Text] [Related]
26. Feasibility of continuous oxygen delivery and cardiac output measurement by application of the Fick principle. Feustel PJ; Perkins RJ; Oppenlander JE; Stratton HH; Cohen IL Am J Respir Crit Care Med; 1994 Mar; 149(3 Pt 1):751-8. PubMed ID: 8118646 [TBL] [Abstract][Full Text] [Related]
27. Validation of continuous thermodilution cardiac output in patients implanted with a left ventricular assist device. Mets B; Frumento RJ; Bennett-Guerrero E; Naka Y J Cardiothorac Vasc Anesth; 2002 Dec; 16(6):727-30. PubMed ID: 12486654 [TBL] [Abstract][Full Text] [Related]
28. Assessment of a cardiac output device using arterial pulse waveform analysis, Vigileo, in cardiac surgery compared to pulmonary arterial thermodilution. Hamm JB; Nguyen BV; Kiss G; Wargnier JP; Jauffroy A; Helaine L; Arvieux CC; Gueret G Anaesth Intensive Care; 2010 Mar; 38(2):295-301. PubMed ID: 20369763 [TBL] [Abstract][Full Text] [Related]
29. Comparison between cardiac output measured by thermodilution technique and calculated by O2 and modified CO2 Fick methods using a new metabolic monitor. Brandi LS; Bertolini R; Pieri M; Giunta F; Calafà M Intensive Care Med; 1997 Aug; 23(8):908-15. PubMed ID: 9310812 [TBL] [Abstract][Full Text] [Related]
31. Continuous invasive cardiac output monitoring--the Baxter/Edwards Critical-Care Swan Ganz IntelliCath and Viligance system. Munro HM; Wood CE; Taylor BL; Smith GB Clin Intensive Care; 1994; 5(2):52-5. PubMed ID: 10147254 [TBL] [Abstract][Full Text] [Related]
32. Validation of a continuous, arterial pressure-based cardiac output measurement: a multicenter, prospective clinical trial. McGee WT; Horswell JL; Calderon J; Janvier G; Van Severen T; Van den Berghe G; Kozikowski L Crit Care; 2007; 11(5):R105. PubMed ID: 17880692 [TBL] [Abstract][Full Text] [Related]
33. Accuracy of continuous thermodilution cardiac output monitoring by pulmonary artery catheter during therapeutic hypothermia in post-cardiac arrest patients. Ameloot K; Meex I; Genbrugge C; Jans F; Malbrain M; Mullens W; Dens J; De Deyne C; Dupont M Resuscitation; 2014 Sep; 85(9):1263-8. PubMed ID: 25008135 [TBL] [Abstract][Full Text] [Related]
34. Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilution. Suttner S; Schöllhorn T; Boldt J; Mayer J; Röhm KD; Lang K; Piper SN Intensive Care Med; 2006 Dec; 32(12):2053-8. PubMed ID: 17039348 [TBL] [Abstract][Full Text] [Related]
35. The Ability of esCCO and ECOM Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method. Thonnerieux M; Alexander B; Binet C; Obadia JF; Bastien O; Desebbe O Anesth Analg; 2015 Aug; 121(2):383-91. PubMed ID: 25902321 [TBL] [Abstract][Full Text] [Related]
36. [Measurement of cardiac output with continuous thermodilution. b1 Clinical experience with the Intellicath-Vigilans system]. Procaccini B; Paladini A; Marfoglia C; Lattanzi FW; Miletti E; Gallo E; Clementi G Minerva Anestesiol; 1997 Nov; 63(11):365-70. PubMed ID: 9549279 [TBL] [Abstract][Full Text] [Related]
37. Comparison of continuous, stat, and intermittent cardiac output measurements in patients undergoing minimally invasive direct coronary artery bypass surgery. Singh A; Juneja R; Mehta Y; Trehan N J Cardiothorac Vasc Anesth; 2002 Apr; 16(2):186-90. PubMed ID: 11957168 [TBL] [Abstract][Full Text] [Related]
38. Evaluation of a new continuous thermodilution cardiac output monitor in cardiac surgical patients: a prospective criterion standard study. Zöllner C; Polasek J; Kilger E; Pichler B; Jaenicke U; Briegel J; Vetter HO; Haller M Crit Care Med; 1999 Feb; 27(2):293-8. PubMed ID: 10075052 [TBL] [Abstract][Full Text] [Related]
39. Continuous versus intermittent cardiac output measurement in cardiac surgical patients undergoing hypothermic cardiopulmonary bypass. Böttiger BW; Rauch H; Böhrer H; Motsch J; Soder M; Fleischer F; Martin E J Cardiothorac Vasc Anesth; 1995 Aug; 9(4):405-11. PubMed ID: 7579110 [TBL] [Abstract][Full Text] [Related]
40. Evaluation of a new invasive continuous cardiac output monitoring system: the truCCOMS system. Thierry S; Thebert D; Brocas E; Razzaghi F; Van De Louw A; Loisance D; Teboul JL Intensive Care Med; 2003 Nov; 29(11):2096-9. PubMed ID: 13680117 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]