These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 8925072)

  • 1. Simultaneous quantitation of oxidised and reduced glutathione in equine biological fluids by reversed-phase high-performance liquid chromatography using electrochemical detection.
    Smith NC; Dunnett M; Mills PC
    J Chromatogr B Biomed Appl; 1995 Nov; 673(1):35-41. PubMed ID: 8925072
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simultaneous femtomole determination of cysteine, reduced and oxidized glutathione, and phytochelatin in maize (Zea mays L.) kernels using high-performance liquid chromatography with electrochemical detection.
    Potesil D; Petrlova J; Adam V; Vacek J; Klejdus B; Zehnalek J; Trnkova L; Havel L; Kizek R
    J Chromatogr A; 2005 Aug; 1084(1-2):134-44. PubMed ID: 16114246
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of Glutathione as a Tool for Oxidative Stress Studies by High Performance Liquid Chromatography.
    Nuhu F; Gordon A; Sturmey R; Seymour AM; Bhandari S
    Molecules; 2020 Sep; 25(18):. PubMed ID: 32933160
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simultaneous Electrochemical Speciation of Oxidized and Reduced Glutathione. Redox Profiling of Oxidative Stress in Biological Fluids with a Modified Carbon Electrode.
    Olmos Moya PM; Martínez Alfaro M; Kazemi R; Alpuche-Avilés MA; Griveau S; Bedioui F; Gutiérrez Granados S
    Anal Chem; 2017 Oct; 89(20):10726-10733. PubMed ID: 28853561
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rapid determination of glutathione status in fish liver using high-performance liquid chromatography and electrochemical detection.
    Rodriguez-Ariza A; Toribio F; López-Barea J
    J Chromatogr B Biomed Appl; 1994 Jun; 656(2):311-8. PubMed ID: 7987482
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validated high-performance liquid chromatography-electrochemical method for determination of glutathione and glutathione disulfide in small tissue samples.
    Lakritz J; Plopper CG; Buckpitt AR
    Anal Biochem; 1997 Apr; 247(1):63-8. PubMed ID: 9126372
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of reduced and oxidized glutathione in erythrocytes by high-performance liquid chromatography with ultraviolet absorbance detection.
    Yoshida T
    J Chromatogr B Biomed Appl; 1996 Apr; 678(2):157-64. PubMed ID: 8738017
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The simultaneous determination of oxidized and reduced glutathiones in liver tissue by ion pairing reverse phase high performance liquid chromatography with a coulometric electrochemical detector.
    Harvey PR; Ilson RG; Strasberg SM
    Clin Chim Acta; 1989 Apr; 180(3):203-12. PubMed ID: 2743574
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validation of a liquid chromatography tandem mass spectrometry method to measure oxidized and reduced forms of glutathione in whole blood and verification in a mouse model as an indicator of oxidative stress.
    Lee SG; Yim J; Lim Y; Kim JH
    J Chromatogr B Analyt Technol Biomed Life Sci; 2016 Apr; 1019():45-50. PubMed ID: 26575459
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A high-performance liquid chromatography method for measurement of oxidized glutathione in biological samples.
    Asensi M; Sastre J; Pallardó FV; García de la Asunción J; Estrela JM; Viña J
    Anal Biochem; 1994 Mar; 217(2):323-8. PubMed ID: 8203763
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A high-performance liquid chromatographic assay for reduced and oxidised glutathione in embryonic, neonatal, and adult tissues using a porous graphite electrochemical detector.
    Carro-Ciampi G; Hunt PG; Turner CJ; Wells PG
    J Pharmacol Methods; 1988 Mar; 19(1):75-83. PubMed ID: 3367651
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Indices of oxidative stress in blood and pulmonary epithelium lining fluid in horses suffering from recurrent airway obstruction.
    Art T; Kirschvink N; Smith N; Lekeux P
    Equine Vet J; 1999 Sep; 31(5):397-401. PubMed ID: 10505955
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of cellular redox status by stable isotope dilution liquid chromatography/mass spectrometry analysis of glutathione and glutathione disulfide.
    Zhu P; Oe T; Blair IA
    Rapid Commun Mass Spectrom; 2008; 22(4):432-40. PubMed ID: 18215009
    [TBL] [Abstract][Full Text] [Related]  

  • 14. HPLC analysis of human erythrocytic glutathione forms using OPA and N-acetyl-cysteine ethyl ester: evidence for nitrite-induced GSH oxidation to GSSG.
    Michaelsen JT; Dehnert S; Giustarini D; Beckmann B; Tsikas D
    J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Oct; 877(28):3405-17. PubMed ID: 19665947
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simultaneous quantification of reduced and oxidized glutathione in plasma using a two-dimensional chromatographic system with parallel porous graphitized carbon columns coupled with fluorescence and coulometric electrochemical detection.
    Sakhi AK; Russnes KM; Smeland S; Blomhoff R; Gundersen TE
    J Chromatogr A; 2006 Feb; 1104(1-2):179-89. PubMed ID: 16376913
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation of high-performance liquid chromatography-boron-doped diamond detection for assessing hepatic glutathione redox status.
    Park HJ; Mah E; Bruno RS
    Anal Biochem; 2010 Dec; 407(2):151-9. PubMed ID: 20705049
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantitation of reduced and total glutathione at the femtomole level by high-performance liquid chromatography with fluorescence detection: application to red blood cells and cultured fibroblasts.
    Cereser C; Guichard J; Drai J; Bannier E; Garcia I; Boget S; Parvaz P; Revol A
    J Chromatogr B Biomed Sci Appl; 2001 Mar; 752(1):123-32. PubMed ID: 11254186
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes.
    Loughlin AF; Skiles GL; Alberts DW; Schaefer WH
    J Pharm Biomed Anal; 2001 Aug; 26(1):131-42. PubMed ID: 11451650
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of glutathione and glutathione disulfide in hepatocytes by liquid chromatography with an electrode modified with functionalized carbon nanotubes.
    Zhang W; Wan F; Zhu W; Xu H; Ye X; Cheng R; Jin LT
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Apr; 818(2):227-32. PubMed ID: 15734163
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Molecular speciated isotope dilution mass spectrometric methods for accurate, reproducible and direct quantification of reduced, oxidized and total glutathione in biological samples.
    Fahrenholz T; Wolle MM; Kingston HM; Faber S; Kern JC; Pamuku M; Miller L; Chatragadda H; Kogelnik A
    Anal Chem; 2015 Jan; 87(2):1232-40. PubMed ID: 25519489
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.