These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
155 related articles for article (PubMed ID: 8926393)
1. SAR characteristics of three types of Contact Flexible Microstrip Applicators for superficial hyperthermia. Lamaitre G; Van Dijk JD; Gelvich EA; Wiersma J; Schneider CJ Int J Hyperthermia; 1996; 12(2):255-69. PubMed ID: 8926393 [TBL] [Abstract][Full Text] [Related]
2. SAR deposition by curved CFMA-434 applicators for superficial hyperthermia: Measurements and simulations. Petra Kok H; Correia D; De Greef M; Van Stam G; Bel A; Crezee J Int J Hyperthermia; 2010; 26(2):171-84. PubMed ID: 20146571 [TBL] [Abstract][Full Text] [Related]
3. Characteristics and performance evaluation of the capacitive Contact Flexible Microstrip Applicator operating at 70 MHz for external hyperthermia. van Wieringen N; Wiersma J; Zum Vörde Sive Vörding P; Oldenborg S; Gelvich EA; Mazokhin VN; van Dijk JD; Crezee J Int J Hyperthermia; 2009 Nov; 25(7):542-53. PubMed ID: 19848617 [TBL] [Abstract][Full Text] [Related]
4. FDTD simulations to assess the performance of CFMA-434 applicators for superficial hyperthermia. Kok HP; De Greef M; Correia D; Vörding PJ; Van Stam G; Gelvich EA; Bel A; Crezee J Int J Hyperthermia; 2009; 25(6):462-76. PubMed ID: 19657850 [TBL] [Abstract][Full Text] [Related]
5. Assessment of the performance characteristics of a prototype 12-element capacitive contact flexible microstrip applicator (CFMA-12) for superficial hyperthermia. Lee WM; Gelvich EA; van der Baan P; Mazokhin VN; van Rhoon GC Int J Hyperthermia; 2004 Sep; 20(6):607-24. PubMed ID: 15370817 [TBL] [Abstract][Full Text] [Related]
6. Large stationary microstrip arrays for superficial microwave hyperthermia at 433 MHz: SAR analysis and clinical data. Ryan TP; Backus VL; Coughlin CT Int J Hyperthermia; 1995; 11(2):187-209. PubMed ID: 7790734 [TBL] [Abstract][Full Text] [Related]
7. Contact flexible microstrip applicators (CFMA) in a range from microwaves up to short waves. Gelvich EA; Mazokhin VN IEEE Trans Biomed Eng; 2002 Sep; 49(9):1015-23. PubMed ID: 12214873 [TBL] [Abstract][Full Text] [Related]
8. Body conformal antennas for superficial hyperthermia: the impact of bending contact flexible microstrip applicators on their electromagnetic behavior. Correia D; Kok HP; de Greef M; Bel A; van Wieringen N; Crezee J IEEE Trans Biomed Eng; 2009 Dec; 56(12):2917-26. PubMed ID: 19695983 [TBL] [Abstract][Full Text] [Related]
9. Design and characterisation of miniaturised cavity-backed patch antenna for microwave hyperthermia. Chakaravarthi G; Arunachalam K Int J Hyperthermia; 2015; 31(7):737-48. PubMed ID: 26365603 [TBL] [Abstract][Full Text] [Related]
10. Effects of fat thickness on heating patterns of the microwave applicator MA-151 at 631 and 915 MHz. Chou CK; McDougall JA; Chan KW; Luk KH Int J Radiat Oncol Biol Phys; 1990 Oct; 19(4):1067-70. PubMed ID: 2211244 [TBL] [Abstract][Full Text] [Related]
11. A 433 MHz Lucite cone waveguide applicator for superficial hyperthermia. van Rhoon GC; Rietveld PJ; van der Zee J Int J Hyperthermia; 1998; 14(1):13-27. PubMed ID: 9483443 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of microwave hyperthermia applicators. Chou CK Bioelectromagnetics; 1992; 13(6):581-97. PubMed ID: 1482420 [TBL] [Abstract][Full Text] [Related]
13. A comparison of the heating characteristics of capacitive and radiative superficial hyperthermia. Kok HP; Crezee J Int J Hyperthermia; 2017 Jun; 33(4):378-386. PubMed ID: 27951733 [TBL] [Abstract][Full Text] [Related]
14. The size and distance of the opposite flat applicator change the SAR and thermal distributions of RF capacitive intracavitary hyperthermia. Hiraki Y; Nakajo M; Takeshita T; Churei H Int J Hyperthermia; 2000; 16(3):205-18. PubMed ID: 10830584 [TBL] [Abstract][Full Text] [Related]
15. Specific absorption rates in simulated tissue media for a 10 x 10 cm 915-MHz waveguide applicator. Denman DL; Kolasa MJ; Elson HR; Aron BS; Kereiakes JG Med Phys; 1987; 14(4):681-6. PubMed ID: 3627011 [TBL] [Abstract][Full Text] [Related]
16. [Measures of specific absorption rate (SAR) in microwave hyperthermic oncology and the influence of the dynamic bolus on clinical practice]. Marini P; Guiot C; Baiotto B; Gabriele P Radiol Med; 2001 Sep; 102(3):159-67. PubMed ID: 11677459 [TBL] [Abstract][Full Text] [Related]
17. Heating pattern of helical microwave intracavitary oesophageal applicator. Liu RL; Zhang EY; Gross EJ; Cetas TC Int J Hyperthermia; 1991; 7(4):577-86. PubMed ID: 1919153 [TBL] [Abstract][Full Text] [Related]
18. Infrared camera based thermometry for quality assurance of superficial hyperthermia applicators. Müller J; Hartmann J; Bert C Phys Med Biol; 2016 Apr; 61(7):2646-64. PubMed ID: 26976046 [TBL] [Abstract][Full Text] [Related]
19. Microstrip-antenna design for hyperthermia treatment of superficial tumors. Montecchia F IEEE Trans Biomed Eng; 1992 Jun; 39(6):580-8. PubMed ID: 1601439 [TBL] [Abstract][Full Text] [Related]
20. Pre-clinical evaluation of a microwave planar array applicator for superficial hyperthermia. Diederich CJ; Stauffer PR Int J Hyperthermia; 1993; 9(2):227-46. PubMed ID: 8468507 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]