390 related articles for article (PubMed ID: 8928517)
1. [Determination of glycosylated hemoglobin in hemoglobin variants].
Schnedl WJ; Reisinger EC
Wien Klin Wochenschr; 1996; 108(14):444. PubMed ID: 8928517
[No Abstract] [Full Text] [Related]
2. [Abnormal hemoglobin (Hb . Takamatsu) detected in routine determination of glycosylated hemoglobin by HbAIc automated analyzer of high performance liquid chromatography--interference in the hemoglobin AIc fraction].
Tanaka Y; Suganuma H; Suzuki M; Kanda T; Harano T; Harano K; Ueda S
Rinsho Byori; 1987 Mar; 35(3):297-302. PubMed ID: 3613146
[No Abstract] [Full Text] [Related]
3. Effects of hemoglobin variants on hemoglobin a1c values measured using a high-performance liquid chromatography method.
Lorenzo-Medina M; De-La-Iglesia S; Ropero P; Nogueira-Salgueiro P; Santana-Benitez J
J Diabetes Sci Technol; 2014 Nov; 8(6):1168-76. PubMed ID: 25355712
[TBL] [Abstract][Full Text] [Related]
4. Is it time for your HbA1c method check-up? Considering the impact of abnormal hemoglobins on HbA1c results.
Noffsinger JK
MLO Med Lab Obs; 2011 Oct; 43(10):26, 28. PubMed ID: 22029151
[No Abstract] [Full Text] [Related]
5. [Incidental detection of hemoglobin abnormalities by HbA1c assay with high pressure liquid chromatography].
Lemée V; Hue G; Lahary A; Lavoinne A
Ann Biol Clin (Paris); 1999; 57(6):713-6. PubMed ID: 10572221
[No Abstract] [Full Text] [Related]
6. Haemoglobin Graz, a novel haemoglobin variant.
Schnedl WJ; Reisinger EC; Pieber TR; Neubauer M; Balaun E; Krejs GJ; Hopmeier P
Diabetologia; 1995 Jan; 38(1):122. PubMed ID: 7744217
[No Abstract] [Full Text] [Related]
7. [Abnormal hemoglobin (Hb Camden) detected by interference in the determination of glycosylated hemoglobin with high performance liquid chromatography].
Shiwa M; Fukuda K; Kawata Y; Matsuura T; Nagao S; Matsuura T; Katsuta I; Hirano M; Ohba Y; Miyaji T
Rinsho Byori; 1988 Jul; 36(7):866-70. PubMed ID: 3236471
[No Abstract] [Full Text] [Related]
8. Assessing blood glucose control in diabetes mellitus. Variant haemoglobin may affect measurements.
Bulusu S
BMJ; 1995 Mar; 310(6981):740; author reply 741. PubMed ID: 7536064
[No Abstract] [Full Text] [Related]
9. [Limits of chromatographic determination of glycated hemoglobin (Hb A1c) in diabetes mellitus in presence of abnormal hemoglobins].
Pashintseva LP; Budantseva TA; Troitskaia OV; Orlova EV; Kleshcheva LV
Klin Lab Diagn; 2001 Jul; (7):39-43. PubMed ID: 11530531
[TBL] [Abstract][Full Text] [Related]
10. An automatic method for determination of glycosylated hemoglobins using low-pressure liquid chromatography.
Blouquit Y; Senan C; Rosa J
J Chromatogr; 1983 Jun; 275(1):41-50. PubMed ID: 6874871
[TBL] [Abstract][Full Text] [Related]
11. Unexpected hemoglobin A1c results.
Sofronescu AG; Williams LM; Andrews DM; Zhu Y
Clin Chem; 2011 Feb; 57(2):153-6. PubMed ID: 21278358
[No Abstract] [Full Text] [Related]
12. Commentary.
Fisher SJ
Clin Chem; 2011 Feb; 57(2):157. PubMed ID: 21278360
[No Abstract] [Full Text] [Related]
13. Hemoglobin "Hope" interferes with measurement of glycated hemoglobin by ion-exchange chromatography and electrophoresis.
King ME; Rifai N; Malekpour A
Clin Chem; 1984 Jun; 30(6):1106-7. PubMed ID: 6723027
[No Abstract] [Full Text] [Related]
14. Hemoglobin D [beta 121(GH4)Glu-->Gln] causing falsely low and high HbA1c values in HPLC.
Schnedl WJ; Lipp RW; Trinker M; Hopmeier P
Clin Chem; 1998 Sep; 44(9):1999-2000. PubMed ID: 9732995
[No Abstract] [Full Text] [Related]
15. Abnormal hemoglobin variant: a source of error in chromatographic determination of HbA1.
Koivisto VA; Ekblom M; Icén A; Hekali R; Groop L
Diabetes Care; 1982; 5(6):650-1. PubMed ID: 6927739
[No Abstract] [Full Text] [Related]
16. Incidental Detection of Hb Disorders During HbA1c Analysis.
Urrechaga E
J Diabetes Sci Technol; 2015 May; 9(3):713. PubMed ID: 25711683
[No Abstract] [Full Text] [Related]
17. Is This Diabetes? A Case of Very High Hemoglobin A1c.
Dennis G; Pyle-Eilola AL
Clin Chem; 2020 Feb; 66(2):394-395. PubMed ID: 32040570
[No Abstract] [Full Text] [Related]
18. Interference of Hemoglobin N-Baltimore on Measurement of HbA1c Using the HA-8160 and HA-8180 HPLC Methods.
Lorenzo-Medina M; Nogueira-Salgueiro P; Martin-Aguila A; Ruiz-Garcia L
J Diabetes Sci Technol; 2015 May; 9(3):714-5. PubMed ID: 25711685
[No Abstract] [Full Text] [Related]
19. Visual detection of abnormal hemoglobin with a procedure for glycated hemoglobin.
Howard CP; Reddig NA; Meek K
Clin Chem; 1984 May; 30(5):818-9. PubMed ID: 6713656
[No Abstract] [Full Text] [Related]
20. Effect of hemoglobin Porto Alegre on glycated hemoglobin (HbA(1c)) measurement with the HA-8160 high performance liquid chromatography method.
Lorenzo-Medina M; De-La-Iglesia S; Ropero P; Martín-Aguila A; Ruiz-García L
Clin Chem Lab Med; 2013 Oct; 51(10):e247-9. PubMed ID: 23612667
[No Abstract] [Full Text] [Related]
[Next] [New Search]