These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 8933451)

  • 1. Bend testing of wrought wire removable partial denture alloys.
    Waldmeier MD; Grasso JE; Norberg GJ; Nowak MD
    J Prosthet Dent; 1996 Nov; 76(5):559-65. PubMed ID: 8933451
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fatigue resistance and stress of wrought-steel wire clasps.
    Vallittu PK
    J Prosthodont; 1996 Sep; 5(3):186-92. PubMed ID: 9028223
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of cast Ti-Ni alloy clasp retention with conventional removable partial denture clasps.
    Kim D; Park C; Yi Y; Cho L
    J Prosthet Dent; 2004 Apr; 91(4):374-82. PubMed ID: 15116040
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Deflection fatigue of cobalt-chromium, titanium, and gold alloy cast denture clasp.
    Vallittu PK; Kokkonen M
    J Prosthet Dent; 1995 Oct; 74(4):412-9. PubMed ID: 8531162
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of titanium and cobalt-chromium removable partial denture clasps.
    Bridgeman JT; Marker VA; Hummel SK; Benson BW; Pace LL
    J Prosthet Dent; 1997 Aug; 78(2):187-93. PubMed ID: 9260137
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Non-linear finite element stress analysis of plastic deformation in Co-Cr wrought-wire clasps.
    Shirasu K; Wakabayashi N; Yoneyama T; Igarashi Y
    Dent Mater; 2008 Nov; 24(11):1518-24. PubMed ID: 18462786
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Guidelines for the choice of circumferential wrought wire and cast clasp arms for removable partial dentures.
    Owen CP; Naidoo N
    Int Dent J; 2022 Feb; 72(1):58-66. PubMed ID: 33622544
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the retentive force of a b-type Ti-6Mo-4Sn alloy wire clasp.
    Yoda N; Yokoyama M; Adachi G; Takahashi M; Sasaki K
    Int J Prosthodont; 2010; 23(1):38-41. PubMed ID: 20234890
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of bending on the mechanical properties of gold wrought-wire clasps: a non-linear finite element analysis.
    Oda N; Wakabayashi N; Yoneyama T; Suzuki T
    Dent Mater J; 2009 Jan; 28(1):121-7. PubMed ID: 19280977
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Flexibility and hardness of dental stainless steel wrought wires used in Thailand.
    Benjakul P; Cheunarrom C; Ongthiemsak C
    J Oral Sci; 2001 Mar; 43(1):15-9. PubMed ID: 11383631
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of various removable partial denture clasp materials and fabrication procedure for placing clasps on canine and premolar teeth.
    VandenBrink JP; Wolfaardt JF; Faulkner MG
    J Prosthet Dent; 1993 Aug; 70(2):180-8. PubMed ID: 8103801
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A new design for partial denture circumferential clasp arms.
    Brockhurst PJ
    Aust Dent J; 1996 Oct; 41(5):317-23. PubMed ID: 8961605
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bending properties of Ce-TZP/A nanocomposite clasps for removable partial dentures.
    Urano S; Hotta Y; Miyazaki T; Baba K
    Int J Prosthodont; 2015; 28(2):191-7. PubMed ID: 25822308
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stress-relaxation testing. Part III: Influence of wire alloys, gauges, and lengths on clasp behavior.
    Brudvik JS; Morris HF
    J Prosthet Dent; 1981 Oct; 46(4):374-9. PubMed ID: 7028952
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of clasp retention forces and abrasion on different cast crowns.
    Jiang N; Gao WM; Zhang H; Zheng DX
    J Prosthet Dent; 2014 Jun; 111(6):493-8. PubMed ID: 24423460
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Study on elastic limit and relevant enclasp force of non-precious metal casting clasp].
    Cheng H; Zheng M; Wu WQ; Huang ZY; Li XR; Cheng XR
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2004 May; 39(3):227-9. PubMed ID: 15196393
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Influence of residual stress in wrought wire clasps on bending properties].
    Shirasu K
    Kokubyo Gakkai Zasshi; 2008 Mar; 75(1):6-12. PubMed ID: 18421947
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Metal framework modifications to accommodate wrought wire clasps in distal extension removable partial dentures.
    Krug RS
    J Prosthet Dent; 2003 Jan; 89(1):79-81. PubMed ID: 12589292
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative study of circumferential clasp retention force for titanium and cobalt-chromium removable partial dentures.
    Rodrigues RC; Ribeiro RF; de Mattos Mda G; Bezzon OL
    J Prosthet Dent; 2002 Sep; 88(3):290-6. PubMed ID: 12426499
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flexible removable partial dentures: design and clasp concepts.
    Kaplan P
    Dent Today; 2008 Dec; 27(12):120, 122-3. PubMed ID: 19133643
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.