216 related articles for article (PubMed ID: 8947901)
21. Reducing electron contamination for photon beam-quality specification.
Li XA; Rogers DW
Med Phys; 1994 Jun; 21(6):791-7. PubMed ID: 7935216
[TBL] [Abstract][Full Text] [Related]
22. Absorbed dose from contaminant electrons inside and outside megavoltage photon beams.
Raffaele L; Ielo I; Settineri N; Tosi G; Brambilla MG; Cattani F
Radiol Med; 1993 Oct; 86(4):513-20. PubMed ID: 8248591
[TBL] [Abstract][Full Text] [Related]
23. Electron beam characteristics of the 50-MeV racetrack microtron.
Karlsson M; Nyström H; Svensson H
Med Phys; 1992; 19(2):307-15. PubMed ID: 1584123
[TBL] [Abstract][Full Text] [Related]
24. Influence of electron contamination on in vivo surface dosimetry for high-energy photon beams.
Sjögren R; Karlsson M
Med Phys; 1998 Jun; 25(6):916-21. PubMed ID: 9650182
[TBL] [Abstract][Full Text] [Related]
25. Evaluation of Al2O3:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy.
Yukihara EG; Mardirossian G; Mirzasadeghi M; Guduru S; Ahmad S
Med Phys; 2008 Jan; 35(1):260-9. PubMed ID: 18293581
[TBL] [Abstract][Full Text] [Related]
26. The use of an extra-focal electron source to model collimator-scattered electrons using the pencil-beam redefinition algorithm.
Boyd RA; Hogstrom KR; White RA; Antolak JA
Med Phys; 2002 Nov; 29(11):2571-83. PubMed ID: 12462724
[TBL] [Abstract][Full Text] [Related]
27. On the discrepancies between Monte Carlo dose calculations and measurements for the 18 MV varian photon beam.
Chibani O; Ma CM
Med Phys; 2007 Apr; 34(4):1206-16. PubMed ID: 17500452
[TBL] [Abstract][Full Text] [Related]
28. Surface and buildup dose characteristics for 6, 10, and 18 MV photons from an Elekta Precise linear accelerator.
Klein EE; Esthappan J; Li Z
J Appl Clin Med Phys; 2003; 4(1):1-7. PubMed ID: 12540813
[TBL] [Abstract][Full Text] [Related]
29. Calculated absorbed-dose ratios, TG51/TG21, for most widely used cylindrical and parallel-plate ion chambers over a range of photon and electron energies.
Tailor RC; Hanson WF
Med Phys; 2002 Jul; 29(7):1464-72. PubMed ID: 12148727
[TBL] [Abstract][Full Text] [Related]
30. Superheated drop detector for determination of neutron dose equivalent to patients undergoing high-energy x-ray and electron radiotherapy.
Nath R; Meigooni AS; King CR; Smolen S; d'Errico F
Med Phys; 1993; 20(3):781-7. PubMed ID: 8350837
[TBL] [Abstract][Full Text] [Related]
31. A Monte Carlo study on neutron and electron contamination of an unflattened 18-MV photon beam.
Mesbahi A
Appl Radiat Isot; 2009 Jan; 67(1):55-60. PubMed ID: 18760613
[TBL] [Abstract][Full Text] [Related]
32. Feasibility study of multileaf collimated electrons with a scattering foil based accelerator.
Klein EE; Li Z; Low DA
Radiother Oncol; 1996 Nov; 41(2):189-96. PubMed ID: 9004363
[TBL] [Abstract][Full Text] [Related]
33. Beam characteristics of energy-matched flattening filter free beams.
Paynter D; Weston SJ; Cosgrove VP; Evans JA; Thwaites DI
Med Phys; 2014 May; 41(5):052103. PubMed ID: 24784392
[TBL] [Abstract][Full Text] [Related]
34. Photon contamination in 8-20-MeV electron beams from a linear accelerator.
Gur D; Bukovitz AG; Serago C
Med Phys; 1979; 6(2):145-6. PubMed ID: 111019
[TBL] [Abstract][Full Text] [Related]
35. Photon-beam subsource sensitivity to the initial electron-beam parameters.
Fix MK; Keall PJ; Siebers JV
Med Phys; 2005 Apr; 32(4):1164-75. PubMed ID: 15895600
[TBL] [Abstract][Full Text] [Related]
36. Fast IMRT with narrow high energy scanned photon beams.
Andreassen B; Strååt SJ; Holmberg R; Näfstadius P; Brahme A
Med Phys; 2011 Aug; 38(8):4774-84. PubMed ID: 21928650
[TBL] [Abstract][Full Text] [Related]
37. Peripheral dose measurements for 6 and 18 MV photon beams on a linear accelerator with multileaf collimator.
Mazonakis M; Zacharopoulou F; Varveris H; Damilakis J
Med Phys; 2008 Oct; 35(10):4396-403. PubMed ID: 18975685
[TBL] [Abstract][Full Text] [Related]
38. Characteristics of an 18 MV photon beam from a Therac 20 Medical Linear Accelerator.
Patterson MS; Shragge PC
Med Phys; 1981; 8(3):312-8. PubMed ID: 6798391
[TBL] [Abstract][Full Text] [Related]
39. Commissioning and dosimetric characteristics of TrueBeam system: composite data of three TrueBeam machines.
Chang Z; Wu Q; Adamson J; Ren L; Bowsher J; Yan H; Thomas A; Yin FF
Med Phys; 2012 Nov; 39(11):6981-7018. PubMed ID: 23127092
[TBL] [Abstract][Full Text] [Related]
40. Investigation of buildup dose from electron contamination of clinical photon beams.
Petti PL; Goodman MS; Gabriel TA; Mohan R
Med Phys; 1983; 10(1):18-24. PubMed ID: 6405143
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]