These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 8949828)

  • 1. An effective method of scavenging nitric oxide.
    Squire S; Kightley R; Petros AJ
    Br J Anaesth; 1996 Sep; 77(3):432-4. PubMed ID: 8949828
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reduction in nitrogen dioxide concentration by soda lime preparations during simulated nitric oxide inhalation.
    Weimann J; Hagenah JU; Motsch J
    Br J Anaesth; 1997 Nov; 79(5):641-4. PubMed ID: 9422905
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The role of soda lime during administration of inhaled nitric oxide.
    Pickett JA; Moors AH; Latimer RD; Mahmood N; Ghosh S; Oduro A
    Br J Anaesth; 1994 Jun; 72(6):683-5. PubMed ID: 8024917
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of nitrogen dioxide scavengers during delivery of inhaled nitric oxide.
    Lindberg L; Rydgren G
    Br J Anaesth; 1998 Sep; 81(3):404-8. PubMed ID: 9861131
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Absorption of nitrogen dioxide and nitric oxide by soda lime.
    Ishibe T; Sato T; Hayashi T; Kato N; Hata T
    Br J Anaesth; 1995 Sep; 75(3):330-3. PubMed ID: 7547053
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Nitric oxide (NO)/nitrogen dioxide (NO2) scavengers.
    Troncy E; Francoeur M; Blaise G
    Br J Anaesth; 1998 May; 80(5):697-8. PubMed ID: 9691882
    [No Abstract]   [Full Text] [Related]  

  • 7. Reduction of NO2 by a NO2-selective scavenger.
    Gilly H; Krebs C; Nowotny T
    Acta Anaesthesiol Scand Suppl; 1996; 109():83-4. PubMed ID: 8901958
    [No Abstract]   [Full Text] [Related]  

  • 8. Extraction of nitric oxide and nitrogen dioxide from an oxygen carrier using molecular sieve 5A.
    Poulton BB; Foubert L; Klinowski J; Latimer RD; Knowles PR; Vuylsteke A
    Br J Anaesth; 1996 Oct; 77(4):534-6. PubMed ID: 8942343
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Effects of temperature and humidity on the stability of nitric oxide, and efficacy of soda lime as a selective absorber of nitrogen dioxide].
    Aida A; Miyamoto K; Saito S; Nakano T; Nishimura M; Kawakami Y; Omori Y; Ando S; Ichida T; Ishibe Y
    Nihon Kyobu Shikkan Gakkai Zasshi; 1995 Mar; 33(3):306-11. PubMed ID: 7739173
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Elimination of nitrogen dioxide and nitric oxide by soda lime and its components].
    Zhang D; Hu X; Liu J
    Zhonghua Yi Xue Za Zhi; 1997 May; 77(5):363-6. PubMed ID: 9772493
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Safety aspects of delivery and monitoring of nitric oxide during mechanical ventilation.
    Westfelt UN; Lundin S; Stenqvist O
    Acta Anaesthesiol Scand; 1996 Mar; 40(3):302-10. PubMed ID: 8721460
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Halothane absorption by dry soda lime].
    Stuttmann R; Knüttgen D; Müller MR; Winkert AT; Doehn M
    Anaesthesist; 1993 Mar; 42(3):157-61. PubMed ID: 8480902
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of a small soda lime canister in a to-and-fro system.
    Kadim MY; Lockwood GG; Chakrabarti MK; Whitwam JG
    Anaesthesia; 1991 Nov; 46(11):952-6. PubMed ID: 1750599
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The in vitro performance of carbon dioxide absorbents with and without strong alkali apparatus.
    Bedi A; Gallagher AC; Fee JP; Murray JM
    Anaesthesia; 2001 Jun; 56(6):546-50. PubMed ID: 11412160
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Reactivity of sevoflurane with carbon dioxide absorbents--comparison of soda lime and Baralyme].
    Miyano K; Nakazawa M; Tanifuji Y; Kobayashi K; Obata T
    Masui; 1991 Mar; 40(3):384-90. PubMed ID: 1906551
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A portable nitric oxide scavenging system designed for use on neonatal transport.
    Dhillon JS; Kronick JB; Singh NC; Johnson CC
    Crit Care Med; 1996 Jun; 24(6):1068-71. PubMed ID: 8681575
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Halothane adsorption complicating the use of soda-lime to humidify anaesthetic gases.
    Grodin WK; Epstein RA
    Br J Anaesth; 1982 May; 54(5):555-9. PubMed ID: 7073923
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [The scavenging system designed for inhaled nitric oxide].
    Liu F; Liu Z
    Zhongguo Yi Liao Qi Xie Za Zhi; 1997 Sep; 21(5):279-80. PubMed ID: 11189277
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The regeneration of soda lime following absorption of carbon dioxide.
    FOREGGER R
    Anesthesiology; 1948 Jan; 9(1):15-20. PubMed ID: 18912117
    [No Abstract]   [Full Text] [Related]  

  • 20. The absorption and degradation of isoflurane and I-653 by dry soda lime at various temperatures.
    Eger EI; Strum DP
    Anesth Analg; 1987 Dec; 66(12):1312-5. PubMed ID: 3688503
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.