179 related articles for article (PubMed ID: 8953445)
1. Transcranial high-intensity Doppler signals in patients with mechanical heart valve prostheses: their relationship with abnormal intracavitary echoes.
Deklunder G; Lecroart JL; Savoye C; Coquet B; Houdas Y
J Heart Valve Dis; 1996 Nov; 5(6):662-7. PubMed ID: 8953445
[TBL] [Abstract][Full Text] [Related]
2. [Usefulness of magnetic resonance imaging for managing patients with prosthetic carbon valve in the mitral position].
Koito H; Imai Y; Suzuki J; Ohkubo N; Nakamura C; Takahashi H; Iwasaka T; Inada M
J Cardiol; 1997 Nov; 30(5):251-63. PubMed ID: 9395956
[TBL] [Abstract][Full Text] [Related]
3. [Doppler echocardiography in assessing mechanical and biological heart valve prostheses].
Minardi G; Di Segni M; Boccardi L; Ferrari O; Giovannini E
G Ital Cardiol; 1988 Feb; 18(2):121-34. PubMed ID: 3410201
[TBL] [Abstract][Full Text] [Related]
4. On the origin of cerebrovascular microemboli associated with prosthetic heart valves.
Mackay TG; Georgiadis D; Grosset DG; Lees KR; Wheatley DJ
Neurol Res; 1995 Oct; 17(5):349-52. PubMed ID: 8584125
[TBL] [Abstract][Full Text] [Related]
5. [High-intensity transcranial Doppler signals in patients wearing heart valve prostheses: a prospective study].
D'Alfonso A; Milano AD; Codecasa R; De Carlo M; Nardi C; Orlandi G; Paoli C; Murri L; Bortolotti U
G Ital Cardiol; 1999 Apr; 29(4):401-10. PubMed ID: 10327318
[TBL] [Abstract][Full Text] [Related]
6. Prospective evaluation of frequency and nature of transcranial high-intensity Doppler signals in prosthetic valve recipients.
Milano A; D'Alfonso A; Codecasa R; De Carlo M; Nardi C; Orlandi G; Landucci L; Bortolotti U
J Heart Valve Dis; 1999 Sep; 8(5):488-94. PubMed ID: 10517388
[TBL] [Abstract][Full Text] [Related]
7. Limitations of Doppler echocardiography in the assessment of prosthetic valve hemodynamics.
Henneke KH; Pongratz G; Bachmann K
J Heart Valve Dis; 1995 Jan; 4(1):18-25. PubMed ID: 7742982
[TBL] [Abstract][Full Text] [Related]
8. Transcranial Doppler detection of microemboli in prosthetic heart valve patients: dependency upon valve type.
Georgiadis D; Kaps M; Berg J; Mackay TG; Dapper F; Faichney A; Wheatley DJ; Lees KR
Eur J Cardiothorac Surg; 1996; 10(4):253-7; discussion 257-8. PubMed ID: 8740061
[TBL] [Abstract][Full Text] [Related]
9. Intracranial high-intensity transient signals after homograft or mechanical aortic valve replacement.
Lievense AM; Bakker SL; Dippel DW; Taams MA; Koudstaal PJ; Bogers AJ
J Cardiovasc Surg (Torino); 1998 Oct; 39(5):613-7. PubMed ID: 9833721
[TBL] [Abstract][Full Text] [Related]
10. [Doppler echocardiographic evaluation of the new mechanical bileaflet Sorin Bicarbon valve prosthesis compared with St. Jude Medical].
Badano L; Carratino L; De Gaetano G; Piazza R; Calisi P; Passerone G; Lucatti A
G Ital Cardiol; 1994 Jun; 24(6):733-43. PubMed ID: 8088472
[TBL] [Abstract][Full Text] [Related]
11. Detection of microemboli by transcranial Doppler ultrasound.
Grosset DG; Georgiadis D; Kelman AW; Cowburn P; Stirling S; Lees KR; Faichney A; Mallinson A; Quin R; Bone I; Pettigrew L; Brodie E; MacKay T; Wheatley DJ
Tex Heart Inst J; 1996; 23(4):289-92. PubMed ID: 8969029
[TBL] [Abstract][Full Text] [Related]
12. Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: an evaluation of clinical, transthoracic and transesophageal echocardiographic parameters.
Barbetseas J; Nagueh SF; Pitsavos C; Toutouzas PK; Quiñones MA; Zoghbi WA
J Am Coll Cardiol; 1998 Nov; 32(5):1410-7. PubMed ID: 9809956
[TBL] [Abstract][Full Text] [Related]
13. Impact of high intensity transient signals on the choice of mechanical aortic valve substitutes.
Laas J; Kseibi S; Perthel M; Klingbeil A; El-Ayoubi L; Alken A
Eur J Cardiothorac Surg; 2003 Jan; 23(1):93-6. PubMed ID: 12493511
[TBL] [Abstract][Full Text] [Related]
14. A method to distinguish between gaseous and solid cerebral emboli in patients with prosthetic heart valves.
Rodriguez RA; Nathan HJ; Ruel M; Rubens F; Dafoe D; Mesana T
Eur J Cardiothorac Surg; 2009 Jan; 35(1):89-95. PubMed ID: 18952455
[TBL] [Abstract][Full Text] [Related]
15. [The value of using transesophageal echocardiographic Doppler color flow imaging in patients undergoing cardiac valvular surgery].
Jiang L
Zhonghua Xin Xue Guan Bing Za Zhi; 1990 Aug; 18(4):195-7, 252. PubMed ID: 2086176
[TBL] [Abstract][Full Text] [Related]
16. [Late complications following Björk-Shiley and St. Jude Medical heart valve replacement].
Horstkotte D; Körfer R; Budde T; Haerten K; Schulte HD; Bircks W; Loogen F
Z Kardiol; 1983 May; 72(5):251-61. PubMed ID: 6880335
[TBL] [Abstract][Full Text] [Related]
17. Spontaneously appearing microbubbles associated with prosthetic cardiac valves detected by transesophageal echocardiography.
Orsinelli DA; Pasierski TJ; Pearson AC
Am Heart J; 1994 Nov; 128(5):990-6. PubMed ID: 7942493
[TBL] [Abstract][Full Text] [Related]
18. [Three-dimensional transesophageal echocardiographic assessment for prosthetic valves].
Sezai A; Shiono M; Orime Y; Hata H; Yagi S; Tsukamoto S; Nakata K; Hasegawa M; Sezai Y; Tanigawa N
Nihon Kyobu Geka Gakkai Zasshi; 1997 Aug; 45(8):1084-9. PubMed ID: 9301234
[TBL] [Abstract][Full Text] [Related]
19. Hemolysis, high-intensity transient signals (HITS) and hemodynamic results after aortic valve replacement with the Medtronic Hall Easy-Fit heart valve prosthesis.
Warnecke RH; Laas J; Hecker H; Perthel M; Alken A
J Heart Valve Dis; 2006 Mar; 15(2):174-9. PubMed ID: 16607897
[TBL] [Abstract][Full Text] [Related]
20. Transesophageal color Doppler flow imaging in the evaluation of prosthetic cardiac valves.
Hsiung MC; Ku CS; Wei J; Ding YA; Lin CC; Wang DJ; Shieh SM; Lin KC
Echocardiography; 1992 Nov; 9(6):583-8. PubMed ID: 10147796
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]