1. Motion and image artifacts of various intracranial aneurysm clips in a magnetic field. Ooka K; Shibuya M; Suzuki Y Acta Neurochir (Wien); 1996; 138(10):1241-5. PubMed ID: 8955445 [TBL] [Abstract][Full Text] [Related]
2. Aneurysm clip MR artifacts. Titanium versus stainless steel and influence of imaging parameters. Burtscher IM; Owman T; Romner B; Ståhlberg F; Holtås S Acta Radiol; 1998 Jan; 39(1):70-6. PubMed ID: 9498874 [TBL] [Abstract][Full Text] [Related]
3. Aneurysm clips: evaluation of magnetic field interactions with an 8.0 T MR system. Kangarlu A; Shellock FG J Magn Reson Imaging; 2000 Jul; 12(1):107-11. PubMed ID: 10931570 [TBL] [Abstract][Full Text] [Related]
11. In vitro evaluation of MR imaging issues at 3T for aneurysm clips made from MP35N: Findings and information applied to 155 additional aneurysm clips. Shellock FG; Valencerina S AJNR Am J Neuroradiol; 2010 Apr; 31(4):615-9. PubMed ID: 20037131 [TBL] [Abstract][Full Text] [Related]
12. Aneurysm clips: evaluation of MR imaging artifacts at 1.5 T. Shellock FG; Kanal E Radiology; 1998 Nov; 209(2):563-6. PubMed ID: 9807590 [TBL] [Abstract][Full Text] [Related]
13. Titanium aneurysm clips: mechanical characteristics and clinical trial. Nagatani T; Shibuya M; Ooka K; Suzuki Y; Takayasu M; Yoshida J Neurol Med Chir (Tokyo); 1998; 38 Suppl():39-44. PubMed ID: 10234976 [TBL] [Abstract][Full Text] [Related]
14. Mechanical and surface properties of Yasargil Phynox aneurysm clips after long-term implantation in a patient with cerebral aneurysm. Otawara Y; Ogasawara K; Kubo Y; Kashimura H; Ogawa A; Watanabe K Neurosurg Rev; 2009 Apr; 32(2):193-6; discussion 196-7. PubMed ID: 19085028 [TBL] [Abstract][Full Text] [Related]
15. Aneurysm clips: evaluation of magnetic field interactions and translational attraction by use of "long-bore" and "short-bore" 3.0-T MR imaging systems. Shellock FG; Tkach JA; Ruggieri PM; Masaryk TJ; Rasmussen PA AJNR Am J Neuroradiol; 2003 Mar; 24(3):463-71. PubMed ID: 12637298 [TBL] [Abstract][Full Text] [Related]
16. Aneurysm clip motion during magnetic resonance imaging: in vivo experimental study with metallurgical factor analysis. Dujovny M; Kossovsky N; Kossowsky R; Valdivia R; Suk JS; Diaz FG; Berman SK; Cleary W Neurosurgery; 1985 Oct; 17(4):543-8. PubMed ID: 4058687 [TBL] [Abstract][Full Text] [Related]