These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 8957785)

  • 21. Prosthetic rehabilitation of partial ear loss with custom-made acrylic attachment and long-term soft liner.
    Chand P; Agrawal KK; Bhalla G; Singh K; Jurel SK; Goel P; Singh SV
    Prosthet Orthot Int; 2013 Dec; 37(6):477-80. PubMed ID: 23386627
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Magnet-retained auricular prosthesis with an implant-supported composite bar: a clinical report.
    Chung RW; Siu AS; Chu FC; Chow TW
    J Prosthet Dent; 2003 May; 89(5):446-9. PubMed ID: 12806320
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Implant-retained thumb prosthesis with anti-rotational attachment for a geriatric patient.
    Goiato MC; Garcia-JĂșnior IR; Magro-Filho O; dos Santos DM; Pellizzer EP
    Gerodontology; 2010 Sep; 27(3):243-7. PubMed ID: 20002205
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Vacuum-formed matrix as a guide for the fabrication of craniofacial implant tissue bar-retained auricular prostheses.
    Cheng AC; Morrison D; Cho RS; Archibald D
    J Prosthet Dent; 1998 Jun; 79(6):711-4. PubMed ID: 9627903
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Fabrication of a new silicone auricular prosthesis without removing the existing metallic framework.
    Goveas R; Shrestha B; Srithavaj ML; Thaworanunta S
    J Prosthet Dent; 2014 Dec; 112(6):1605-8. PubMed ID: 24998323
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Retention systems for extraoral maxillofacial prosthetic implants: a critical review.
    Cobein MV; Coto NP; Crivello Junior O; Lemos JBD; Vieira LM; Pimentel ML; Byrne HJ; Dias RB
    Br J Oral Maxillofac Surg; 2017 Oct; 55(8):763-769. PubMed ID: 28552609
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Results of treatment of 20 patients with implant-retained auricular prostheses.
    Watson RM; Coward TJ; Forman GH
    Int J Oral Maxillofac Implants; 1995; 10(4):445-9. PubMed ID: 7672847
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Preoperative auricular wax pattern duplication for surgical template fabrication.
    Wang R
    J Prosthet Dent; 1999 May; 81(5):634-7. PubMed ID: 10220672
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Implant-retained auricular prosthesis.
    Demir N; Malkoc MA; Ozturk AN; Tosun Z
    J Craniofac Surg; 2010 Nov; 21(6):1795-7. PubMed ID: 21119423
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Osseointegrated implants and auricular defects: a case series study.
    Wright RF; Zemnick C; Wazen JJ; Asher E
    J Prosthodont; 2008 Aug; 17(6):468-75. PubMed ID: 18544137
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Fixation of facial and auricular prosthesis with osseous implants in cranial bone].
    Raghoebar GM; van Oort RP; Dikkers FG; Reintsema H
    Ned Tijdschr Geneeskd; 1998 Mar; 142(10):525-8. PubMed ID: 9623100
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Duplication of an existing implant-supported bar for an auricular prosthesis.
    Tarica DY; Brajevic FJ
    J Prosthet Dent; 2008 May; 99(5):408-9. PubMed ID: 18456053
    [No Abstract]   [Full Text] [Related]  

  • 33. Alternative retention for an implant-retained auricular prosthesis.
    Mekayarajjananonth T; LoCascio SJ; Winkler S; Salinas TJ; Guerra LR
    J Oral Implantol; 2002; 28(3):117-21. PubMed ID: 12498442
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Fabrication and use of a surgical template for placing implants to retain an auricular prosthesis.
    Asher ES; Evans JH; Wright RF; Wazen JJ
    J Prosthet Dent; 1999 Feb; 81(2):228-33. PubMed ID: 9922439
    [TBL] [Abstract][Full Text] [Related]  

  • 35. An impression and cast construction technique for implant-retained auricular prostheses.
    Wolfaardt JF; Coss P
    J Prosthet Dent; 1996 Jan; 75(1):45-9. PubMed ID: 8850450
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Magnetic retention and bar-clip attachment for implant-retained auricular prostheses: a comparative analysis.
    de Sousa AA; Mattos BS
    Int J Prosthodont; 2008; 21(3):233-6. PubMed ID: 18548962
    [TBL] [Abstract][Full Text] [Related]  

  • 37. An implant-retained auricular impression technique to minimize soft tissue distortion.
    Kubon TM; Anderson JD
    J Prosthet Dent; 2003 Jan; 89(1):97-101. PubMed ID: 12589298
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [An auricular prosthesis attached by intra-mastoid implants. Apropos of 11 cases].
    Foussadier F; Menard P; Zaza R; Pillet J; Bertrand JC
    Rev Stomatol Chir Maxillofac; 1993; 94(5):312-7. PubMed ID: 8235427
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Freestanding magnetic retention for extraoral prosthesis with osseointegrated implants.
    Thomas KF
    J Prosthet Dent; 1995 Feb; 73(2):162-5. PubMed ID: 7722932
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Anterior margin adaptation for implant-retained auricular prostheses.
    Dumbrigue HB; Fyler A; Mercier LA
    J Prosthet Dent; 1997 Oct; 78(4):425-8. PubMed ID: 9338877
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.