These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

79 related articles for article (PubMed ID: 8970373)

  • 1. Quantitative videobronchoscopy: a new technique to assess airway caliber.
    Forkert L; Watanabe H; Sutherland K; Vincent S; Fisher JT
    Am J Respir Crit Care Med; 1996 Dec; 154(6 Pt 1):1794-803. PubMed ID: 8970373
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of airway caliber in quantitative videobronchoscopy.
    Czaja P; Soja J; Grzanka P; Cmiel A; Szczeklik A; Sładek K
    Respiration; 2007; 74(4):432-8. PubMed ID: 17164541
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Adding the third dimension--a new tool for constructing 3D models of the airway from 2D bronchoscopic video.
    Bromwich M; Murugappan S; Willging JP
    Int J Pediatr Otorhinolaryngol; 2009 Sep; 73(9):1202-7. PubMed ID: 19505733
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Upper airway dimensions in children using rigid video-bronchoscopy and a computer software: description of a measurement technique.
    Dalal PG; Murray D; Feng A; Molter D; McAllister J
    Paediatr Anaesth; 2008 Jul; 18(7):645-53. PubMed ID: 18482248
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Laser-based endoscopic measurement of airway dimensions].
    Dörffel WV; Sugano YT; Stalling D; Coconu L; Hentschel D; Linss G; Witt Ch
    Pneumologie; 2003 Sep; 57(9):503-9. PubMed ID: 13680470
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new method to perform quantitative measurement of bronchoscopic images.
    McFawn PK; Forkert L; Fisher JT
    Eur Respir J; 2001 Nov; 18(5):817-26. PubMed ID: 11757633
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new method for objective identification and measurement of airway lumen in paediatric flexible videobronchoscopy.
    Masters IB; Eastburn MM; Wootton R; Ware RS; Francis PW; Zimmerman PV; Chang AB
    Thorax; 2005 Aug; 60(8):652-8. PubMed ID: 16061706
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of airways with three-dimensional quantitative thin-section CT: in vitro and in vivo validation.
    Montaudon M; Berger P; de Dietrich G; Braquelaire A; Marthan R; Tunon-de-Lara JM; Laurent F
    Radiology; 2007 Feb; 242(2):563-72. PubMed ID: 17179398
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A new bronchoscopic method to measure airway size.
    Dörffel WV; Fietze I; Hentschel D; Liebetruth J; Rückert Y; Rogalla P; Wernecke KD; Baumann G; Witt C
    Eur Respir J; 1999 Oct; 14(4):783-8. PubMed ID: 10573220
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of pixel size on quantification of airway wall thickness in computed tomography.
    Achenbach T; Weinheimer O; Dueber C; Heussel CP
    J Comput Assist Tomogr; 2009; 33(5):725-30. PubMed ID: 19820501
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Airway narrowing in porcine bronchi with and without lung parenchyma.
    Noble PB; Sharma A; McFawn PK; Mitchell HW
    Eur Respir J; 2005 Nov; 26(5):804-11. PubMed ID: 16264040
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measuring airway dimensions during bronchoscopy using anatomical optical coherence tomography.
    Williamson JP; Armstrong JJ; McLaughlin RA; Noble PB; West AR; Becker S; Curatolo A; Noffsinger WJ; Mitchell HW; Phillips MJ; Sampson DD; Hillman DR; Eastwood PR
    Eur Respir J; 2010 Jan; 35(1):34-41. PubMed ID: 19541718
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accurate measurement of intrathoracic airways.
    Reinhardt JM; D'Souza ND; Hoffman EA
    IEEE Trans Med Imaging; 1997 Dec; 16(6):820-7. PubMed ID: 9533582
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assessment of pulmonary airway reactivity with high-resolution CT.
    Herold CJ; Brown RH; Mitzner W; Links JM; Hirshman CA; Zerhouni EA
    Radiology; 1991 Nov; 181(2):369-74. PubMed ID: 1924774
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Morphometric bronchoscopy in adults with central airway obstruction: case illustrations and review of the literature.
    Murgu S; Colt HG
    Laryngoscope; 2009 Jul; 119(7):1318-24. PubMed ID: 19444886
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Robust 3-D airway tree segmentation for image-guided peripheral bronchoscopy.
    Graham MW; Gibbs JD; Cornish DC; Higgins WE
    IEEE Trans Med Imaging; 2010 Apr; 29(4):982-97. PubMed ID: 20335095
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Videoendoscopic distortion correction and its application to virtual guidance of endoscopy.
    Helferty JP; Zhang C; McLennan G; Higgins WE
    IEEE Trans Med Imaging; 2001 Jul; 20(7):605-17. PubMed ID: 11465467
    [TBL] [Abstract][Full Text] [Related]  

  • 18. New method for quantitative assessment of airway calibre using a stereovision fibreoptic bronchoscope.
    Hayashi A; Takanashi S; Tsushima T; Denpoya J; Okumura K; Hirota K
    Br J Anaesth; 2012 Mar; 108(3):512-6. PubMed ID: 22201182
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Virtual bronchoscopy in children: early clinical experience.
    Konen E; Katz M; Rozenman J; Ben-Shlush A; Itzchak Y; Szeinberg A
    AJR Am J Roentgenol; 1998 Dec; 171(6):1699-702. PubMed ID: 9843316
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of methacholine-induced airway constriction by ultrafast high-resolution computed tomography.
    Amirav I; Kramer SS; Grunstein MM; Hoffman EA
    J Appl Physiol (1985); 1993 Nov; 75(5):2239-50. PubMed ID: 8307884
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.