These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
186 related articles for article (PubMed ID: 8973960)
1. A finite element analysis of the load transfer between an above-knee residual limb and its prosthetic socket--roles of interface friction and distal-end boundary conditions. Zhang M; Mak AF IEEE Trans Rehabil Eng; 1996 Dec; 4(4):337-46. PubMed ID: 8973960 [TBL] [Abstract][Full Text] [Related]
2. Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket. Zhang L; Zhu M; Shen L; Zheng F Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1270-3. PubMed ID: 24109926 [TBL] [Abstract][Full Text] [Related]
3. Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket. Lee WC; Zhang M; Jia X; Cheung JT Med Eng Phys; 2004 Oct; 26(8):655-62. PubMed ID: 15471693 [TBL] [Abstract][Full Text] [Related]
4. A quasi-dynamic nonlinear finite element model to investigate prosthetic interface stresses during walking for trans-tibial amputees. Jia X; Zhang M; Li X; Lee WC Clin Biomech (Bristol); 2005 Jul; 20(6):630-5. PubMed ID: 15878224 [TBL] [Abstract][Full Text] [Related]
5. Development of a non-linear finite element modelling of the below-knee prosthetic socket interface. Zhang M; Lord M; Turner-Smith AR; Roberts VC Med Eng Phys; 1995 Dec; 17(8):559-66. PubMed ID: 8564149 [TBL] [Abstract][Full Text] [Related]
6. [Three-dimensional finite element analyses on the transtibial residual limb and its prosthetic socket]. Zhang M; Mak AF; Fan Y Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2000 Dec; 17(4):403-6. PubMed ID: 11211825 [TBL] [Abstract][Full Text] [Related]
7. Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: a new tool for prosthetic fitting. Portnoy S; Yarnitzky G; Yizhar Z; Kristal A; Oppenheim U; Siev-Ner I; Gefen A Ann Biomed Eng; 2007 Jan; 35(1):120-35. PubMed ID: 17120139 [TBL] [Abstract][Full Text] [Related]
8. Incidence of the boundary condition between bone and soft tissue in a finite element model of a transfemoral amputee. Ramírez JF; Vélez JA Prosthet Orthot Int; 2012 Dec; 36(4):405-14. PubMed ID: 22354886 [TBL] [Abstract][Full Text] [Related]
9. Frictional action at lower limb/prosthetic socket interface. Zhang M; Turner-Smith AR; Roberts VC; Tanner A Med Eng Phys; 1996 Apr; 18(3):207-14. PubMed ID: 8718946 [TBL] [Abstract][Full Text] [Related]
10. Load transfer mechanics between trans-tibial prosthetic socket and residual limb--dynamic effects. Jia X; Zhang M; Lee WC J Biomech; 2004 Sep; 37(9):1371-7. PubMed ID: 15275844 [TBL] [Abstract][Full Text] [Related]
12. Interface mechanics in lower-limb external prosthetics: a review of finite element models. Zachariah SG; Sanders JE IEEE Trans Rehabil Eng; 1996 Dec; 4(4):288-302. PubMed ID: 8973955 [TBL] [Abstract][Full Text] [Related]
13. Influence of the scale reduction in designing sockets for trans-tibial amputees. Dakhil N; Tarrade T; Behr M; Mo F; Evin M; Thefenne L; Liu T; Llari M Proc Inst Mech Eng H; 2020 Aug; 234(8):761-768. PubMed ID: 32475295 [TBL] [Abstract][Full Text] [Related]
14. Comparison of computational analysis with clinical measurement of stresses on below-knee residual limb in a prosthetic socket. Zhang M; Roberts C Med Eng Phys; 2000 Nov; 22(9):607-12. PubMed ID: 11259929 [TBL] [Abstract][Full Text] [Related]
15. [Function of prosthesis components in lower limb amputees with bone-anchored percutaneous implants : Biomechanical aspects]. Blumentritt S Unfallchirurg; 2017 May; 120(5):385-394. PubMed ID: 28280845 [TBL] [Abstract][Full Text] [Related]
16. Transtibial prosthetic socket pistoning: static evaluation of Seal-In(®) X5 and Dermo(®) Liner using motion analysis system. Gholizadeh H; Osman NA; Kamyab M; Eshraghi A; Abas WA; Azam MN Clin Biomech (Bristol); 2012 Jan; 27(1):34-9. PubMed ID: 21794965 [TBL] [Abstract][Full Text] [Related]
17. A photoelastic clinical study of the static load distribution at the stump/socket interface of PTB sockets. Sewell P; Vinney J; Noroozi S; Amali R; Andrews S Prosthet Orthot Int; 2005 Dec; 29(3):291-302. PubMed ID: 16466158 [TBL] [Abstract][Full Text] [Related]
18. Ultrasound imaging in lower limb prosthetics. Douglas T; Solomonidis S; Sandham W; Spence W IEEE Trans Neural Syst Rehabil Eng; 2002 Mar; 10(1):11-21. PubMed ID: 12173735 [TBL] [Abstract][Full Text] [Related]
19. Finite element modelling of a residual lower-limb in a prosthetic socket: a survey of the development in the first decade. Zhang M; Mak AF; Roberts VC Med Eng Phys; 1998 Jul; 20(5):360-73. PubMed ID: 9773689 [TBL] [Abstract][Full Text] [Related]
20. A three-dimensional finite element model of the transibial residual limb and prosthetic socket to predict skin temperatures. Peery JT; Klute GK; Blevins JJ; Ledoux WR IEEE Trans Neural Syst Rehabil Eng; 2006 Sep; 14(3):336-43. PubMed ID: 17009493 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]