These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
343 related articles for article (PubMed ID: 8974691)
1. [Solid phase technique versus gel centrifugation for detection of erythrocyte antibodies--a prospective study comparison the 2 antibody detection tests]. Zeiler T; Thiele S; Kretschmer V Beitr Infusionsther Transfusionsmed; 1996; 33():17-21. PubMed ID: 8974691 [TBL] [Abstract][Full Text] [Related]
2. [Superiority of the gel centrifugation method (ID System) in detection of erythrocyte antibodies]. Kretschmer V; Heuckeroth A; Schulzki T; Dietrich G Beitr Infusionsther; 1992; 30():375-7. PubMed ID: 1284738 [TBL] [Abstract][Full Text] [Related]
3. [The gel centrifugation test: comparison of antibody identification at 37 degrees C with antibody identification at room temperature]. Hitzler WE; Ulrich M; Däumer C; Beeser H Infusionsther Transfusionsmed; 1993 Jun; 20 Suppl 2():61-3. PubMed ID: 8374292 [TBL] [Abstract][Full Text] [Related]
4. Comparison of the performance of microtube column systems and solid-phase systems and the tube low-ionic-strength solution additive indirect antiglobulin test in the detection of red cell alloantibodies. Weisbach V; Kohnhäuser T; Zimmermann R; Ringwald J; Strasser E; Zingsem J; Eckstein R Transfus Med; 2006 Aug; 16(4):276-84. PubMed ID: 16879156 [TBL] [Abstract][Full Text] [Related]
5. [Comparative study of antibody identification in the gel centrifugation test (ID Microtyping System), solid phase antiglobulin test (Solidscreen Capture R, Ready ID) and tube test]. Hitzler W; Johanson C; Schömig-Brekner J; Mathias D Beitr Infusionsther; 1992; 30():370-4. PubMed ID: 1284737 [TBL] [Abstract][Full Text] [Related]
6. [Effect of HLA antibodies on the gel centrifugation test]. Stangenberg W; Kretschmer V; Ponath N Beitr Infusionsther Transfusionsmed; 1996; 33():43-6. PubMed ID: 8974707 [TBL] [Abstract][Full Text] [Related]
7. [ID and Bio Vue systems--comparison of two systems for the typing of erythrocyte antibodies]. Eichler H; Klinge U; Kretschmer V Beitr Infusionsther Transfusionsmed; 1994; 32():149-52. PubMed ID: 9480072 [TBL] [Abstract][Full Text] [Related]
8. [Observations on antibody determination and differentiation with papain test erythrocytes using the gel centrifugation technique (ID-Microtyping System)]. Strobel E; Wüllenweber J Infusionsther Transfusionsmed; 1995 Feb; 22(1):25-30. PubMed ID: 7727960 [TBL] [Abstract][Full Text] [Related]
9. [Detection of erythrocyte antibodies using solid phase assays]. Beckmann-Emami E; Emami M; Kühnl P; Lliger C Beitr Infusionsther; 1990; 26():342-4. PubMed ID: 1703869 [TBL] [Abstract][Full Text] [Related]
10. Superiority of gel centrifugation in antibody screening and identification. Kretschmer V; Heuckeroth A; Schulzki T; Dietrich G Infusionsther Transfusionsmed; 1992 Oct; 19(5):226-30. PubMed ID: 1288765 [TBL] [Abstract][Full Text] [Related]
11. [3 new antibody detection tests. A comparative study]. Mempel W; Alraun K; Leeping M; Kirschner M; Reiser H; Heim MU Beitr Infusionsther; 1990; 26():362-6. PubMed ID: 1703872 [TBL] [Abstract][Full Text] [Related]
12. Two-stage papain-indirect antiglobulin test and LISS direct agglutination are not appropriate for pretransfusion screening for unexpected antibodies. Pereira A; Mazzara R; Gelabert A; Castillo R Haematologica; 1991; 76(6):475-8. PubMed ID: 1820984 [TBL] [Abstract][Full Text] [Related]
13. [Evaluation of the polyethyleneglycol antiglobulin test in the detection and identification of erythrocyte antibodies]. Jiménez Marco MT; Hernández Maraver D; Rodríguez de la Rua A; de la Cámara Mendizábal C; Canales Albendea M; Jiménez Yuste V; Hernández Navarro F Sangre (Barc); 1998 Feb; 43(1):21-4. PubMed ID: 9577178 [TBL] [Abstract][Full Text] [Related]
14. [Capture-R Ready-ID and DiaMed-ID for identification of erythrocyte bound antibodies after acid elution]. Beck KH; Kaup N; Ilse R; Beeser H Beitr Infusionsther Transfusionsmed; 1997; 34():171-5. PubMed ID: 9417339 [TBL] [Abstract][Full Text] [Related]
15. [Suitability of monoclonal test sera for determination of blood group markers in positive direct Coombs test]. Strobel E; Wüllenweber J Infusionsther Transfusionsmed; 1995 Apr; 22(2):117-27. PubMed ID: 7787405 [TBL] [Abstract][Full Text] [Related]
16. [Positive direct antiglobulin test (DAGT) using the gel system]. Frey-Wettstein M; Froelicher S Beitr Infusionsther; 1992; 30():378-81. PubMed ID: 1284739 [TBL] [Abstract][Full Text] [Related]
17. [Initial results of a prospective study with automated solid phase and column/agglutination techniques in screening for transfusion relevant IgG antibodies]. Simson G; Lynen R; Bialek C; Kloppmann T; Bargmann I; Köhler M Infusionsther Transfusionsmed; 1993 Jun; 20 Suppl 2():52-7. PubMed ID: 8374290 [TBL] [Abstract][Full Text] [Related]
18. [Evaluation of the test using polybrene for the detection of anti-erythrocyte antibodies]. Lenkiewicz B Acta Haematol Pol; 1991; 22(1):127-35. PubMed ID: 1823954 [TBL] [Abstract][Full Text] [Related]
19. [The LISS technique-a more sensitive and faster method for erythrocyte antibody detection (author's transl)]. Smetana R Wien Klin Wochenschr; 1981 Apr; 93(7):215-8. PubMed ID: 7257415 [TBL] [Abstract][Full Text] [Related]
20. Production of soluble recombinant proteins with Kell, Duffy and Lutheran blood group antigen activity, and their use in screening human sera for Kell, Duffy and Lutheran antibodies. Ridgwell K; Dixey J; Scott ML Transfus Med; 2007 Oct; 17(5):384-94. PubMed ID: 17725551 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]