243 related articles for article (PubMed ID: 8982984)
1. Amperometric microsensors for monitoring choline in the extracellular fluid of brain.
Garguilo MG; Michael AC
J Neurosci Methods; 1996 Dec; 70(1):73-82. PubMed ID: 8982984
[TBL] [Abstract][Full Text] [Related]
2. Quantitation of choline in the extracellular fluid of brain tissue with amperometric microsensors.
Garguilo MG; Michael AC
Anal Chem; 1994 Sep; 66(17):2621-9. PubMed ID: 7943733
[TBL] [Abstract][Full Text] [Related]
3. Acetylcholine and choline amperometric enzyme sensors characterized in vitro and in vivo.
Mitchell KM
Anal Chem; 2004 Feb; 76(4):1098-106. PubMed ID: 14961744
[TBL] [Abstract][Full Text] [Related]
4. Carbon fibre-based microbiosensors for in vivo measurements of acetylcholine and choline.
Schuvailo ON; Dzyadevych SV; El'skaya AV; Gautier-Sauvigné S; Csöregi E; Cespuglio R; Soldatkin AP
Biosens Bioelectron; 2005 Jul; 21(1):87-94. PubMed ID: 15967355
[TBL] [Abstract][Full Text] [Related]
5. Rapid assessment of in vivo cholinergic transmission by amperometric detection of changes in extracellular choline levels.
Parikh V; Pomerleau F; Huettl P; Gerhardt GA; Sarter M; Bruno JP
Eur J Neurosci; 2004 Sep; 20(6):1545-54. PubMed ID: 15355321
[TBL] [Abstract][Full Text] [Related]
6. Monitoring glutamate and ascorbate in the extracellular space of brain tissue with electrochemical microsensors.
Kulagina NV; Shankar L; Michael AC
Anal Chem; 1999 Nov; 71(22):5093-100. PubMed ID: 10575963
[TBL] [Abstract][Full Text] [Related]
7. Electrosynthesized poly(pyrrole)/poly(2-naphthol) bilayer membrane as an effective anti-interference layer for simultaneous determination of acethylcholine and choline by a dual electrode amperometric biosensor.
Guerrieri A; Lattanzio V; Palmisano F; Zambonin PG
Biosens Bioelectron; 2006 Mar; 21(9):1710-8. PubMed ID: 16169212
[TBL] [Abstract][Full Text] [Related]
8. Amperometric sensors for peroxide, choline, and acetylcholine based on electron transfer between horseradish peroxidase and a redox polymer.
Garguilo MG; Huynh N; Proctor A; Michael AC
Anal Chem; 1993 Mar; 65(5):523-8. PubMed ID: 8452244
[TBL] [Abstract][Full Text] [Related]
9. Development of choline and acetylcholine Pt microelectrodes.
Huang Z; Villarta-Snow R; Lubrano GJ; Guilbault GG
Anal Biochem; 1993 Nov; 215(1):31-7. PubMed ID: 8297012
[TBL] [Abstract][Full Text] [Related]
10. Pharmacological evidence for the selectivity of in vivo signals obtained with enzyme-based electrochemical sensors.
Cui J; Kulagina NV; Michael AC
J Neurosci Methods; 2001 Jan; 104(2):183-9. PubMed ID: 11164244
[TBL] [Abstract][Full Text] [Related]
11. Choline biosensor constructed with chitinous membrane from soldier crab and its application in measuring cholinesterase inhibitory activities.
Hsieh BC; Matsumoto K; Cheng TJ; Yuu G; Chen RL
J Pharm Biomed Anal; 2007 Nov; 45(4):673-8. PubMed ID: 17329059
[TBL] [Abstract][Full Text] [Related]
12. Bienzymatic amperometric biosensor for choline based on mediator thionine in situ electropolymerized within a carbon paste electrode.
Yang M; Yang Y; Yang Y; Shen G; Yu R
Anal Biochem; 2004 Nov; 334(1):127-34. PubMed ID: 15464961
[TBL] [Abstract][Full Text] [Related]
13. Simultaneous determination of acetylcholine, choline and physostigmine in microdialysis samples from rat hippocampus by microbore liquid chromatography/electrochemistry on peroxidase redox polymer coated electrodes.
Kehr J; Dechent P; Kato T; Ogren SO
J Neurosci Methods; 1998 Sep; 83(2):143-50. PubMed ID: 9765127
[TBL] [Abstract][Full Text] [Related]
14. Monitoring hydrogen peroxide in the extracellular space of the brain with amperometric microsensors.
Kulagina NV; Michael AC
Anal Chem; 2003 Sep; 75(18):4875-81. PubMed ID: 14674466
[TBL] [Abstract][Full Text] [Related]
15. Comparative in vivo effects of parathion on striatal acetylcholine accumulation in adult and aged rats.
Karanth S; Liu J; Ray A; Pope C
Toxicology; 2007 Oct; 239(3):167-79. PubMed ID: 17707571
[TBL] [Abstract][Full Text] [Related]
16. An acetylcholinesterase/choline oxidase-based amperometric biosensors as a liquid chromatography detector for acetylcholine and choline determination in brain tissue homogenates.
Guerrieri A; Palmisano F
Anal Chem; 2001 Jul; 73(13):2875-82. PubMed ID: 11467530
[TBL] [Abstract][Full Text] [Related]
17. Ceramic-based multisite microelectrode arrays for simultaneous measures of choline and acetylcholine in CNS.
Burmeister JJ; Pomerleau F; Huettl P; Gash CR; Werner CE; Bruno JP; Gerhardt GA
Biosens Bioelectron; 2008 Apr; 23(9):1382-9. PubMed ID: 18243683
[TBL] [Abstract][Full Text] [Related]
18. Improving the reproducibility of hydrogel-coated glutamate microsensors by using an automated dipcoater.
Oldenziel WH; Beukema W; Westerink BH
J Neurosci Methods; 2004 Dec; 140(1-2):117-26. PubMed ID: 15589341
[TBL] [Abstract][Full Text] [Related]
19. A performance comparison of choline biosensors: anodic or cathodic detections of H2O2 generated by enzyme immobilized on a conducting polymer.
Rahman MA; Park DS; Shim YB
Biosens Bioelectron; 2004 Jul; 19(12):1565-71. PubMed ID: 15142589
[TBL] [Abstract][Full Text] [Related]
20. Role of high-affinity choline uptake on extracellular choline and acetylcholine evoked by NMDA.
Zapata A; Capdevila JL; Trullas R
Synapse; 2000 Mar; 35(4):272-80. PubMed ID: 10657037
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]