144 related articles for article (PubMed ID: 8988512)
1. Comparison of multileaf collimation and shield alloy blocks on an irregular target volume.
Dirican B; Beyzadeoglu M; Turgay HT; Pak Y
Radiat Med; 1996; 14(5):293-6. PubMed ID: 8988512
[TBL] [Abstract][Full Text] [Related]
2. [The application of the multileaf collimator in radiotherapy: the dosimetric problems and the technical implications for its clinical use].
Corvò R; Foppiano F; Orsatti M; Bisi F; Ghiso G; Martinelli R; Valanzola L; Vitale V
Radiol Med; 1997 Nov; 94(5):512-9. PubMed ID: 9465218
[TBL] [Abstract][Full Text] [Related]
3. [Dosimetric characterization of a multileaf collimator].
Stasi M; Baiotto B; Palamara F; Gabriele P; Scielzo G
Radiol Med; 1999 May; 97(5):382-8. PubMed ID: 10432971
[TBL] [Abstract][Full Text] [Related]
4. Dosimetric evaluation of the conformation of the multileaf collimator to irregularly shaped fields.
Frazier A; Du M; Wong J; Vicini F; Taylor R; Yu C; Matter R; Martinez A; Yan D
Int J Radiat Oncol Biol Phys; 1995 Dec; 33(5):1229-38. PubMed ID: 7493847
[TBL] [Abstract][Full Text] [Related]
5. [Physical-dosimetric characterization of a multi-leaf collimator system for clinical implementation in conformational radiotherapy].
Pasquino M; Casanova Borca V; Tofani S
Radiol Med; 2001 Mar; 101(3):187-92. PubMed ID: 11402959
[TBL] [Abstract][Full Text] [Related]
6. Dosimetric assessment of the field abutment region in head and neck treatments using a multileaf collimator.
Abdel-Hakim K; Nishimura T; Takaih M; Suzuki S; Sakahara H
Strahlenther Onkol; 2003 May; 179(5):312-9. PubMed ID: 12740658
[TBL] [Abstract][Full Text] [Related]
7. The acceptability of a multileaf collimator as a replacement for conventional blocks.
Fernandez EM; Shentall GS; Mayles WP; Dearnaley DP
Radiother Oncol; 1995 Jul; 36(1):65-74. PubMed ID: 8525027
[TBL] [Abstract][Full Text] [Related]
8. Radiotherapy of prostate cancer with multileaf collimators (MLCs) optimization of the undulating dose distribution at the MLC edge.
Koelbl O; Schwab F; Bratengeier K; Vordermark D; Flentje M
Strahlenther Onkol; 2005 Feb; 181(2):108-12. PubMed ID: 15702299
[TBL] [Abstract][Full Text] [Related]
9. A comparison of multileaf-collimator and alloy-block field shaping.
Galvin JM; Han K; Cohen R
Int J Radiat Oncol Biol Phys; 1998 Feb; 40(3):721-31. PubMed ID: 9486625
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of MLC leaf positioning using a scanning liquid ionization chamber EPID.
Mohammadi M; Bezak E
Phys Med Biol; 2007 Jan; 52(1):N21-33. PubMed ID: 17183123
[TBL] [Abstract][Full Text] [Related]
11. [Dosimetric analysis of radiotherapy with middle shielding blocks of different widths at the lower cervical supraclavicular field for stage N2-3 nasopharyngeal carcinoma].
Li FM; Luo W; He ZC; Zhang L; Sun Y; Qin WJ; Lu LX; Han F; Liu XQ; Liu MZ
Ai Zheng; 2007 Oct; 26(10):1127-32. PubMed ID: 17927886
[TBL] [Abstract][Full Text] [Related]
12. Peripheral dose from a linear accelerator equipped with multileaf collimation.
Stern RL
Med Phys; 1999 Apr; 26(4):559-63. PubMed ID: 10227359
[TBL] [Abstract][Full Text] [Related]
13. Simplified intensity-modulated arc therapy for dose escalated prostate cancer radiotherapy.
Bauman G; Gete E; Chen JZ; Wong E
Med Dosim; 2004; 29(1):18-25. PubMed ID: 15023389
[TBL] [Abstract][Full Text] [Related]
14. Field Shaping for Three-Dimensional Conformal Radiation Therapy and Multileaf Collimation.
Mohan R
Semin Radiat Oncol; 1995 Apr; 5(2):86-99. PubMed ID: 10717132
[TBL] [Abstract][Full Text] [Related]
15. An experimental investigation into the radiation field offset of a dynamic multileaf collimator.
Vial P; Oliver L; Greer PB; Baldock C
Phys Med Biol; 2006 Nov; 51(21):5517-38. PubMed ID: 17047267
[TBL] [Abstract][Full Text] [Related]
16. Improvement in dose homogeneity with electronic tissue compensation over IMRT and conventional RT in whole brain radiotherapy.
Goyal S; Yue NJ; Millevoi R; Kagan E; Haffty B; Narra V
Radiother Oncol; 2008 Aug; 88(2):196-201. PubMed ID: 18362037
[TBL] [Abstract][Full Text] [Related]
17. Dosimetric evaluation and clinical application of virtual mini-multileaf collimator.
Cheng CW; Wong JR; Ndlovu AM; Das IJ; Schiff P; Uematsu M
Am J Clin Oncol; 2003 Jun; 26(3):e37-44. PubMed ID: 12796614
[TBL] [Abstract][Full Text] [Related]
18. A reduction in the AAPM TG-36 reported peripheral dose distributions with tertiary multileaf collimation. American Association of Physicists in Medicine Task Group 36.
Mutic S; Klein EE
Int J Radiat Oncol Biol Phys; 1999 Jul; 44(4):947-53. PubMed ID: 10386654
[TBL] [Abstract][Full Text] [Related]
19. Multileaf collimation versus conventional shielding blocks: a time and motion study of beam shaping in radiotherapy.
Helyer SJ; Heisig S
Radiother Oncol; 1995 Oct; 37(1):61-4. PubMed ID: 8539458
[TBL] [Abstract][Full Text] [Related]
20. Siemens multileaf collimator characterization and quality assurance approaches for intensity-modulated radiotherapy.
Bayouth JE
Int J Radiat Oncol Biol Phys; 2008; 71(1 Suppl):S93-7. PubMed ID: 18406947
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]