BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

189 related articles for article (PubMed ID: 8989195)

  • 1. Technical and methodologic considerations for performance of indirect calorimetry in ventilated and nonventilated preterm infants.
    Thureen PJ; Phillips RE; DeMarie MP; Hoffenberg A; Bronstein MN; Spedale SB; Hay WW
    Crit Care Med; 1997 Jan; 25(1):171-80. PubMed ID: 8989195
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Technical and clinical testing of a computerized indirect calorimeter for use in mechanically ventilated neonates.
    Mayfield SR
    Am J Clin Nutr; 1991 Jul; 54(1):30-4. PubMed ID: 1905477
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Methods to validate the accuracy of an indirect calorimeter in the in-vitro setting.
    Oshima T; Ragusa M; Graf S; Dupertuis YM; Heidegger CP; Pichard C
    Clin Nutr ESPEN; 2017 Dec; 22():71-75. PubMed ID: 29415838
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of face mask, head hood, and canopy for breath sampling in flow-through indirect calorimetry to measure oxygen consumption and carbon dioxide production of preterm infants < 1500 grams.
    Bauer K; Pasel K; Uhrig C; Sperling P; Versmold H
    Pediatr Res; 1997 Jan; 41(1):139-44. PubMed ID: 8979303
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validation of a portable indirect calorimetry system for measurement of energy expenditure in sick preterm infants.
    Shortland GJ; Fleming PJ; Walter JH
    Arch Dis Child; 1992 Oct; 67(10 Spec No):1207-11. PubMed ID: 1444562
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of an indirect calorimeter for mechanically ventilated infants and children: the influence of low rates of gas exchange and varying FIO2.
    Joosten KF; Jacobs FI; van Klaarwater E; Baartmans MG; Hop WC; Meriläinen PT; Hazelzet JA
    Crit Care Med; 2000 Aug; 28(8):3014-8. PubMed ID: 10966288
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Indirect calorimetry in mechanically ventilated children: a new technique that overcomes the problem of endotracheal tube leak.
    Selby AM; McCauley JC; Schell DN; O'Connell A; Gillis J; Gaskin KJ
    Crit Care Med; 1995 Feb; 23(2):365-70. PubMed ID: 7867361
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Energy expenditure and gas exchange measurements in postoperative patients: thermodilution versus indirect calorimetry.
    Brandi LS; Grana M; Mazzanti T; Giunta F; Natali A; Ferrannini E
    Crit Care Med; 1992 Sep; 20(9):1273-83. PubMed ID: 1521442
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Carbon dioxide elimination and oxygen consumption in mechanically ventilated children.
    Smallwood CD; Walsh BK; Bechard LJ; Mehta NM
    Respir Care; 2015 May; 60(5):718-23. PubMed ID: 25550526
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Metabolic monitoring in the intensive care unit: a comparison of the Medgraphics Ultima, Deltatrac II, and Douglas bag collection methods.
    Black C; Grocott MP; Singer M
    Br J Anaesth; 2015 Feb; 114(2):261-8. PubMed ID: 25354946
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vitro validation of a metabolic monitor for gas exchange measurements in ventilated neonates.
    Behrends M; Kernbach M; Bräuer A; Braun U; Peters J; Weyland W
    Intensive Care Med; 2001 Jan; 27(1):228-35. PubMed ID: 11280640
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Indirect calorimetry in mechanically ventilated infants and children: measurement accuracy with absence of audible airleak.
    Chwals WJ; Lally KP; Woolley MM
    Crit Care Med; 1992 Jun; 20(6):768-70. PubMed ID: 1597030
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro validation and clinical testing of an indirect calorimetry system for ventilated preterm infants that is unaffected by endotracheal tube leaks and can be used during nasal continuous positive airway pressure.
    Bauer K; Ketteler J; Laurenz M; Versmold H
    Pediatr Res; 2001 Mar; 49(3):394-401. PubMed ID: 11228266
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Application of indirect calorimetry in monitoring feeding of low birth-weight preterm infants].
    Krämer T; Böhler T; Janecke AR; Hoffmann GF; Linderkamp O
    Klin Padiatr; 1999; 211(5):389-93. PubMed ID: 10572895
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reliability of, and Agreement Between, two Breath-by-Breath Indirect Calorimeters at Varying Levels of Inspiratory Oxygen.
    Poulsen MK; Thomsen LP; Kjaergaard S; Rees SE; Karbing DS
    Nutr Clin Pract; 2019 Oct; 34(5):767-774. PubMed ID: 30714634
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of gas leak around endotracheal tubes on indirect calorimetry measurement.
    Dietrich KA; Romero MD; Conrad SA
    JPEN J Parenter Enteral Nutr; 1990; 14(4):408-13. PubMed ID: 2119449
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of ventilator resetting on indirect calorimetry measurement in the critically ill surgical patient.
    Brandi LS; Bertolini R; Santini L; Cavani S
    Crit Care Med; 1999 Mar; 27(3):531-9. PubMed ID: 10199532
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Continuous breathing circuit flow and tracheal tube cuff leak: sources of error during pediatric indirect calorimetry.
    Räsänen J
    Crit Care Med; 1992 Sep; 20(9):1335-40. PubMed ID: 1521450
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A water-sealed indirect calorimeter for measurement of oxygen consumption (VO2), carbon dioxide production (VCO2), and energy expenditure in infants.
    Dechert RE; Wesley JR; Schafer LE; LaMond S; Nicks J; Coran AG; Bartlett RH
    JPEN J Parenter Enteral Nutr; 1988; 12(3):256-9. PubMed ID: 3134559
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accurate, noninvasive quantitation of expiratory gas leak from uncuffed infant endotracheal tubes.
    Knauth A; Baumgart S
    Pediatr Pulmonol; 1990; 9(1):55-60. PubMed ID: 2117739
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.